DOSIMETER‑RADIOMETER ISS‑AT1117M (STATIONARY‑PORTABLE DOSIMETRIC CONTROL POSTS)
DOSIMETER‑RADIOMETER ISS‑AT1117M (STATIONARY‑PORTABLE DOSIMETRIC CONTROL POSTS)
High sensitivity Audible, light and visual alarm of exceeding the set threshold levels The possibility of using both stationary and wearable versions Automatic recording and storage of at least 10,000 GPS-linked measurement results when using BOI4 The possibility of automatic data transfer to a remote server, as well as processing them in export application software when using BOI4
Produced in: Belarus, Minsk
Gamma radiation dosimeter DKG-03D "Grach"
Gamma radiation dosimeter DKG-03D "Grach"
Purpose: measurement of the ambient dose equivalent of N*(10) gamma radiation; measurement of ambient dose equivalent of N*(10) gamma radiation (operator dose).
Doza
Zelenograd
Produced in: Moscow
Atom Fast 8850 - radiation dosimeter on a scintillator for a smartphone
Atom Fast 8850 - radiation dosimeter on a scintillator for a smartphone
from 29 500 ₽
1 supp.
Technical specifications Overall dimensions of the device (mm) 113*25*14 The service life of the built-in battery is at least 300 cycles within the warranty period of the device. The sensitivity anisotropy according to Cs137 (%) is not more than 30 The full charge time of the built-in battery from the USB port of the PC or charger is no more than 4 hours. Operating time Continuous operation from a fully charged built-in battery in conditions of natural radiation background: - without the use of sound/vibration alarm for at least 2 months; - without using wireless communication and sound/vibration alarm for at least 4 months. Maximum counting speed (imp/sec) 10000 The weight of the device (g) is not more than 50 Note The Atom Fast 8850 can use a cylindrical crystal with a diameter of 10 mm and a height of 40 mm without prior notice. The energy range of the recorded photon radiation (keV) is not less than 60 - 3000 keV Working size of the scintillation detector (mm) 8*8*50 The scope of delivery USB cable for charging the built-in lithium-ion battery 1 pc. Dosimeter set—top box Atom Fast - 1 pc. Packing box 1 pc. Carrying case — 1 pc.
Produced in: Moscow, Troitsk
Individual gamma and neutron radiation dosimeter DVS-02D
Individual gamma and neutron radiation dosimeter DVS-02D
Purpose: measurement of individual dose equivalent (IED) of mixed gamma-neutron radiation; measurement of individual dose equivalent (IED) of neutron radiation;
Doza
Zelenograd
Produced in: Moscow
DOSIMETER‑RADIOMETER MKS‑AT1117M (WITH HERMETIC CONTAINERS FOR DETECTION UNITS)
DOSIMETER‑RADIOMETER MKS‑AT1117M (WITH HERMETIC CONTAINERS FOR DETECTION UNITS)
Measurement of the ambient dose equivalent or absorbed dose rate of gamma radiation in liquid media, wells, underground storage facilities and other hard-to-reach places Compatible with detection units: BDKG-01, BDKG-03, BDKG-04, BDKG-05, BDKG-17, BDKG-24, BDKG-30 Measurement at depths up to 30 meters Marking on the cable to determine the depth of immersion A Cable Winding Coil
Produced in: Belarus, Minsk
X-ray Radiation Dosimeters Clinical DRC
X-ray Radiation Dosimeters Clinical DRC
X–ray radiation dosimeters clinical DRC, depending on the modification, are designed for: measuring the product of the kerma (absorbed dose) in the air by the cross-sectional area of the X-ray beam (hereinafter referred to as the product of the kerma in the air by the area) when using the DRC-1, DRC-1E, DRC-1M Outline, DRC-1M dosimeters with the DRC measuring console-1M-E03, DRC-1M-E04, DRC-1M-E05, DRC-1M-E06; measurements of the product of the kerma power (absorbed dose) in the air per area (hereinafter referred to as the product of the kerma power in the air per area) using the DRK–1E and DRK-1M dosimeters equipped with the DRK-1M-E06 measuring console; measurements of the product of the kerma (absorbed dose) in the air along the length (hereinafter referred to as the product of the kerma in the air along the length) using DRK-1M-CT dosimeters; measurements of kerma (absorbed dose) in the air; measurements of the kerma power (absorbed dose) in the air when using DRK-1M dosimeters.
Doza
Zelenograd
Produced in: Moscow
Gamma and X-ray radiation dosimeter DKG-09D "Chizh"
Gamma and X-ray radiation dosimeter DKG-09D "Chizh"
Purpose: measurement of the ambient dose equivalent of gamma and continuous X-ray (photon) radiation N *(10); measurement of the ambient dose equivalent of gamma and continuous X-ray (photon) radiation N *(10).
Doza
Zelenograd
Produced in: Moscow
Individual thermoluminescent dosimeters
Individual thermoluminescent dosimeters
The principle of operation of dosimeters is based on the accumulation of ionizing radiation energy by detectors proportional to the radiation dose. In DVG-02TM installations, DOZA-TLD complexes, etc., when the detector is heated, the accumulated energy is released in the form of light radiation, which is recorded by an electronic device.
Doza
Zelenograd
Produced in: Moscow
Dosimeter SUR-1TS
Dosimeter SUR-1TS
The possibility of a qualitative assessment of the current radiation situation - continuously and under any conditions. You can put the device in your pocket, purse, etc. and forget about it. If you get into the zone of radioactive exposure, the alarm will immediately remind you of yourself and let you know about the danger with light and sound signals; The presence of light and sound alarms about the emergency level of radiation hazard; Durable body is made of cast duralumin; Protected by the copyright certificate, the original power supply circuit, which provides low current consumption, allows you to keep the device constantly on and instantly determine whether it enters the zone of radioactive danger; The possibility to operate the device without replacing the battery for a year or more.
NPP "ELEKTRONNYE PRIBORY"
Naberezhnye Chelny
Produced in: Tatarstan, Naberezhnye Chelny
DOSIMETERS‑RADIOMETERS ISS‑AT6130, ISS‑AT6130A, ISS‑AT6130D
DOSIMETERS‑RADIOMETERS ISS‑AT6130, ISS‑AT6130A, ISS‑AT6130D
Small-sized devices for measuring the power of the ambient dose equivalent and the ambient dose equivalent of X-ray and gamma radiation, as well as measuring the flux density of beta particles (AT6130). Durable metal case Convenient menu Selective measurement of beta and gamma radiation in mixed fields (AT6130) Measurement of dose rate up to 100 mSv/h (AT6130D) Search mode Headphones for working in noisy environments (on request)