NVDM-100 High-vacuum Diffusion Pump
NVDM-100 High-vacuum Diffusion Pump
The operation of the NVDM-100 diffusion pump is based on the capture and transfer of the pumped gas by a steam jet flowing from the slit gaps of the steam line nozzles towards the outlet flange. The oil reflector of the NVDM-100 diffusion pump is a cap with a cooling tube soldered onto it with fittings. The open heater of the NVDM-100 diffusion pump is a metal housing with a ceramic base laid in it with a heating element made in the form of a spiral of nichrome wire. During the operation of the pump, it is necessary to monitor the flow rate and temperature of the cooling water, the level of the working fluid and its temperature. Replacement or refilling of the working fluid depends on the operating mode of the pump (inlet pressure, pumping duration, etc.) and the composition of the pumped medium. Therefore, the time after which the working fluid is replaced or refilled can be from 100 to 1000 or more hours. A large flow rate of the working fluid is observed when the pump is operating in the range of inlet pressures from 6.6×10-2 to 13.3 Pa (from 5×10-4 to 1×10-1 mm Hg). Water at the inlet to the cooling systems of the housing and oil reflector should be supplied with a pressure of no more than 0.5 MPa (5 kgf / cm2) and temperature from plus 4˚C to plus 25˚C. The recommended cooling water consumption is 35+5 l/h and is regulated by the outlet water temperature, which should not exceed plus 40˚C. The water drain should be free (with a jet break). Not allowed: operation of the pump without water cooling, exceeding the maximum exhaust pressure of 35 Pa (0.263 mm Hg). The level of the working fluid during operation, at which the parameters of the NVDM-100 diffusion pump are provided, must correspond to min 7mm, max 11mm. The volume of the filled working fluid is 0.07/
Produced in: Kazan
Vacuum membrane pump PL.HM02.01.6 Primelab
Vacuum membrane pump PL.HM02.01.6 Primelab
from 195 000 ₽
Vacuum membrane pump PL.HM02.01.6 Primelab is an effective device for creating a vacuum, as well as pumping gases and vapors. Depending on the tasks, you can achieve different device performance, which depends on the method of connecting the cameras. With a series connection, the capacity will be 38 l/min at a maximum vacuum of 6 mbar. Parallel connection of the chambers will lead to a pumping speed of 76 l/min at a maximum vacuum of 45 mbar, and an independent connection at the same vacuum will allow a performance of 38 l/min per chamber. The chemical-resistant diaphragm pump PL.HM02.01.6, developed and manufactured by the domestic company Primelab, meets IP20 protection class. It has a light weight of 8.6 kg and compact dimensions (321.5x140x200 mm). Helps you increase productivity and achieve flawless results in the laboratory.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
3VVN1-12M Water ring vacuum pump
3VVN1-12M Water ring vacuum pump
The working fluid of the pump is water. The use of the 3VVN1-12M(H) pump for pumping out water-gas mixtures is allowed only if the bulk of the water is separated and discharged at the pump entrance. Failure to comply with this requirement may lead to unacceptable overload of the engine and destruction of the pump's working parts. The 3VVN1-12M(H) water ring vacuum pump is not intended for use in fire and explosion hazardous industries. The 3VVN1-12M(H) vacuum water ring pump is manufactured in the climatic version of UHL 4 and O4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, meets the requirements of technical specifications TU 3648-053-00218526-2013, designed and manufactured taking into account the requirements of GOST R 52615-2006.
Produced in: Kazan
2NVR-250D Vacuum rotary vane pump
2NVR-250D Vacuum rotary vane pump
the 2NVR-250D vacuum pump is manufactured in the climatic version of UM 4 (i.e. for moderate climate) according to GOST standard 15150-69, but to be used at ambient temperature and pumped medium 283 K to 308 K (+10˚C to +35˚C). Electricity grid must meet the requrimemnts of GOST 13109-97. The 2NVR-250D vacuum rotary vane pump meets the requirements of technical specifications TU 3648-006-00218526-2002. The 2NVR-250D pump is refueled with VACMA OIL 100 power fluid. The level of the working fluid is monitored by the oil indicator, replenishment is needed when the level of the power fluid is below the minimum level of the oil indicator.
Produced in: Kazan
VEGA ProVac 1500 high-vacuum turbomolecular pump
VEGA ProVac 1500 high-vacuum turbomolecular pump
The complex includes: VEGA ProVac 1500 turbomolecular high vacuum pump; frequency converter; set of mounting parts; operation manual. For connection to the pre-vacuum pumping system, the pump is equipped with an ISO-KF40 exhaust flange. Pump cooling is combined. Based on the operating conditions, the complex can work both with forced air cooling and with water cooling. The working orientation in space is vertical.
Produced in: Vladimir
Vacuum membrane pump PL.HM02.02.8 Primelab
Vacuum membrane pump PL.HM02.02.8 Primelab
from 185 000 ₽
1 supp.
The vacuum membrane pump PL.HM02.02.8 helps speed up the laboratory process by quickly pumping vapors and gases and creating a vacuum. Suitable for working with flammable, toxic and chemically active substances. A special feature of the PL.HM02.02.8 Primelab pump is the ability to customize it for different production tasks: • With a parallel connection, the pumping speed is 76 l/min with a maximum residual pressure of 45 mbar. • With independent connection, 38 l/min at a maximum residual pressure of 45 mbar. • When chambers are connected in series, the flow rate is 38 l/min with a maximum residual pressure of 8 mbar.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
2NVR-5DG Vacuum pump
2NVR-5DG Vacuum pump
The 2NVR-5DG UM4 pump is manufactured in the climatic version of UM 4 (i.e. for moderate climate) according to GOST standard 15150-69, but to be used at ambient temperature and pumped medium 283 K to 308 K (+10˚C to +35˚C). Electricity grid must meet the requrimemnts of GOST 13109-97. The 2NVR-5DG vacuum rotary vane pump meets the requirements of technical specifications TU 3648-006-00218526-2002. The 2NVR-5DG pump is refueled with VACMA OIL 100 working fluid. Monitoring of the level of the working fluid is ensured by the oil indicator, replenishment is neede when the level of the working fluid is below the minimum level of the oil indicator.
Produced in: Kazan
3VVN2-50 Water ring vacuum pump
3VVN2-50 Water ring vacuum pump
The 3VVN2-50(H) water ring vacuum pump is not intended for use in fire and explosion hazardous industries. The 3VVN2-50(H) vacuum water ring pump is manufactured in the climatic version of UHL 4 and O4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, meets the requirements of technical specifications TU 3648-053-00218526-2013, designed and manufactured taking into account the requirements of GOST R 52615-2006.
Produced in: Kazan
NVR-0,1D Plate-rotary vacuum pump
NVR-0,1D Plate-rotary vacuum pump
Pumping out steam-gas mixtures is allowed only when the gas-ballast device is open. The NVR-0,1D vacuum plate-rotary pump is manufactured in the climatic version of UHL 4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, but to be used at ambient temperature and pumped medium 283 K to 308 K (+10˚C to +35˚C). It meets the requirements of technical specifications TU 3648-021-00218526-2001, designed and manufactured taking into account the requirements of GOST R 52615-2006. The quality of electricity must meet the requrimemnts of GOST 53390-2009.
Produced in: Kazan
Vacuum membrane pump PL.HM04.02.01 Primelab
Vacuum membrane pump PL.HM04.02.01 Primelab
from 490 000 ₽
Vacuum membrane pump PL.HM04.02.01 PrimeLab is a compact laboratory device with which you can create a vacuum in the laboratory. It is equipped with innovative membrane technology that ensures high gas pumping speed. Suitable for pumping vapors and gases up to 1 mbar. The PL.HM04.02.01 pump has an excellent safety system. Protection against overheating and overload is provided. All contacting media are made of PTFE, which has rare chemical and physical properties. All control is carried out through vacuum control, which also ensures maximum accuracy and control of all operating parameters. It has a low noise level (75 dB), which does not cause discomfort to the working class.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Vacuum membrane pump PL.HM01.02.6 Primelab
Vacuum membrane pump PL.HM01.02.6 Primelab
from 200 000 ₽
Vacuum membrane pump PL.HM01.02.6 Primelab is a compact, efficient and durable device for creating a vacuum or pumping gases and vapors in laboratory conditions. It has a low noise level (up to 75 dB) and does not require regular maintenance. Warranty and post-warranty service is available in Russia. The equipment is suitable for working with chemically active and toxic substances and does not react with them. The cameras are made of fluoroplastic, and all its parts have a fluoroplastic coating. The pump capacity is 38 l/min at a maximum vacuum of 6 mbar.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
2NVR-5DM1 Rotary vane vacuum pump
2NVR-5DM1 Rotary vane vacuum pump
The 2NVR-5DM1 rotary vane vacuum pump is manufactured in the climatic version of UHL 4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, but to be used at ambient temperature and pumped medium 283 K to 308 K (+10˚C to +35˚C). It meets the requirements of technical specifications TU 3648-006-00218526-2002. It is designed and manufactured taking into account the requirements of GOST R 52615-2006. Electricity grid must meet the requrimemnts of GOST 32144-2013
Produced in: Kazan