Search

51 products
View:
  • Selected: 0
    Applying
  • Selected: 1
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 2
    Applying
  • Names
  • 3
    Manufacturer
  • 4
    Made in
  • 2
    Additional
View:
51 products
2NVBM-630(R)/12000 Booster High Vacuum pump
2NVBM-630(R)/12000 Booster High Vacuum pump
The 2NVBM-630(R)/12000 booster pump consists of housings, a steam pipe, a trap and a heater. The required effective speed of action of the pre-vacuum pump (pumps) at a pressure of 200 Pa (1.5 mm Hg) at the outlet of the 2NVBM-630(R)/12000 booster pump is not less than 100 l/s. The maximum residual pressure of the pump measured by the PMI-2 manometric ionization converter with nitrogen filled into its trap, is no more than 6.6x10-4Pa (5x10-6mm Hg). The pressure of the cooling water at the pump inlet 2NVBM-630(P)/12000 should be from 0.2 to 0.5 MPa (from 2 to 5 kgf / cm2) The discharge from the pump should be free with a jet break. Cooling water consumption 1200 l/h. The total amount of working fluid for the 2NVBM-630(R)/12000 pump is 65 liters, the level of the working fluid should be between the upper and lower marks of the level gauge. Replacement or refilling of the working fluid depends on the operating mode of the pump (inlet pressure, pumping duration, etc.) and the composition of the pumped medium, so the time after which the working fluid is replaced or refilled can be 100 hours or more. A large flow rate of the working fluid is observed when the pump is operating in the input pressure range from 1.33 to 13.3 Pa (from 1x10-2 to 1x10-1 mmHg). The operating mode of the pump in the range from 13.3 Pa (0.1 mmHg) to the maximum residual pressure is cyclically irregular.
Produced in: Kazan
ND-500 High-vacuum diffusion pump
ND-500 High-vacuum diffusion pump
The working condition of the ND-500 diffusion pump depends on the temperature of the working fluid in the pump boiler. During the initial filling, it is recommended to fill the maximum volume of the working fluid. Working fluid is "VACMA OIL 500" vacuum oil (under technical specifications TU 19.20.29-061-00218526-2019). The total amount of working fluid in the ND-500 diffusion pump is a maximum of 5.5 liters, a minimum of 4 liters. The viewing window for visual inspection of the working fluid has marks of its maximum and minimum amounts. During normal operation of the pump, the level of the working fluid practically does not change.The temperature of the working fluid when the pump is operating at the maximum residual pressure is about 240°C to 255°C. It is recommended to monitor the operation of the heaters in the ND-500 diffusion pump using one temperature sensor. The temperature sensor must be installed in a special radiator socket above the heater. If there is a loss of working fluid and an increase in the temperature of the radiators of the ND-500 diffusion pump up to 320°C, the temperature sensor should give the command to automatically turn off the heaters. The subsequent activation of the pump heaters should not be automatic and should be carried out only after cooling the system. Water at the inlet to the cooling systems of the housing and the oil reflector must be supplied with a pressure of 0.3 MPa (3 kgf/cm2) to 0.5 MPa (5 kgf/cm2) and a temperature of plus 4 ° C to plus 25 ° C. The recommended cooling water consumption for the housing is 500 l/h, for the oil reflector it is 50 l / h. It is regulated by the outlet water temperature, which should not exceed plus 40°C. The water drain should be free (with a jet break). The required speed of action of pre-vacuum pumps at a pressure of 26 Pa (0.2 mm Hg.st) in the outlet section of the ND-500 diffusion pump should be at least 42 l/s. To reduce the losses of the working fluid of the ND-500 diffusion pump at pressures (1·10-1- 1) Pa [(7,5·10-4- 7,5·10-3) mmHg] it is recommended to install an additional LP-500 flow-through water trap on the outlet flange.
Produced in: Kazan
Vacuum membrane pump PL.HM04.02.01 Primelab
Vacuum membrane pump PL.HM04.02.01 Primelab
from 490 000 ₽
Vacuum membrane pump PL.HM04.02.01 PrimeLab is a compact laboratory device with which you can create a vacuum in the laboratory. It is equipped with innovative membrane technology that ensures high gas pumping speed. Suitable for pumping vapors and gases up to 1 mbar. The PL.HM04.02.01 pump has an excellent safety system. Protection against overheating and overload is provided. All contacting media are made of PTFE, which has rare chemical and physical properties. All control is carried out through vacuum control, which also ensures maximum accuracy and control of all operating parameters. It has a low noise level (75 dB), which does not cause discomfort to the working class.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Vacuum membrane pump PL.HM01.02.10 Primelab
Vacuum membrane pump PL.HM01.02.10 Primelab
from 150 000 ₽
The vacuum membrane pump PL.HM01.02.10 Primelab is designed for pumping steam-gas-air media, creating a vacuum, vacuum filtration and drying. The valves are made of FFKM, the chambers are made of fluoroplastic, all connecting elements and parts are coated with fluoroplastic. The pump has good performance despite its compact dimensions (321.5x160x200 mm). At a maximum pressure of 10 mbar it is capable of pumping up to 38 l/min. Does not require constant maintenance. Complies with IP20 protection class. It has a low noise level (up to 75 dB), which does not create discomfort for laboratory staff. Supplied complete with equipment sufficient for assembly and start-up.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
3VVN1-6M(N) Water ring vacuum pump
3VVN1-6M(N) Water ring vacuum pump
The working fluid of the pump is water. The use of the 3VVN1-6M(H) pump for pumping out water-gas mixtures is allowed only if the bulk of the water is separated and discharged at the pump entrance. Failure to comply with this requirement may lead to unacceptable overload of the engine and destruction of the pump's working organs. The 3VVN1-6M(H) water ring vacuum pump is not intended for use in fire and explosion hazardous industries. The 3VVN1-6M(H) vacuum water ring pump is manufactured in the climatic version of UHL 4 and O4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, meets the requirements of technical specifications TU 3648-053-00218526-2013, designed and manufactured taking into account the requirements of GOST R 52615-2006.
Produced in: Kazan
2VVN1-12M(N) Water ring vacuum pump
2VVN1-12M(N) Water ring vacuum pump
The use of a 2VVN1-12M(H) water-ring vacuum pump for pumping out water-gas mixtures is allowed only if the bulk of the water is separated and discharged at the pump entrance. Failure to comply with this requirement may lead to unacceptable overload of the electric motor and destruction of the working parts of the 2VVN1-12M(N) pump. The 2VVN1-12M(N) vacuum water ring pump is manufactured in the climatic version of UHL 4 and O4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, meets the requirements of technical specifications TU 3648-015-00218526-2000, designed and manufactured taking into account the requirements of GOST R 52615-2006. The quality of electricity must meet the requrimemnts of GOST 32144-2013.
Produced in: Kazan
Vacuum membrane pump PL.HM02.01.4 Primelab
Vacuum membrane pump PL.HM02.01.4 Primelab
from 250 000 ₽
The vacuum membrane pump PL.HM02.01.4 is a universal device made in Russia from the Primelab company. Made from high-quality materials, including fluoroplastic, used to create sealed chambers, and a protective coating for safe operation of the device. The technical characteristics of the pump depend on the method of connecting the chambers. With a series connection, the performance will be 38 l/min at a maximum vacuum of 4 mbar. Parallel and independent connections will allow you to achieve completely different performance indicators of the device. The vacuum diaphragm pump PL.HM02.01.4 Primelab is convenient to use. It has a light weight of 9 kg, compact dimensions (321.5x160x200 mm) and creates a minimum of noise (up to 75 dB).
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Vacuum membrane pump PL.HM01.01.8 Primelab
Vacuum membrane pump PL.HM01.01.8 Primelab
from 150 000 ₽
The Primelab vacuum diaphragm pump PL.HM01.01.8 has excellent performance - up to 38 l/min at a maximum vacuum of 8 mbar. Suitable for a wide range of industrial and laboratory applications. It is used for working with chemically active substances due to the use of high-quality materials in its design that do not react with toxic reagents. The chambers are made of fluoroplastic, all parts have a fluoroplastic coating. Complies with IP20 protection class. Supplied complete with equipment sufficient for quick assembly and operation of the device. Namely this: vacuum pump, cable, instructions, passport, packaging (vacuum regulator and spare parts are not included in the kit and must be ordered separately).
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Vacuum membrane pump PL.HM01.01.6 Primelab
Vacuum membrane pump PL.HM01.01.6 Primelab
from 180 000 ₽
Vacuum membrane pump PL.HM01.01.6 Primelab is a compact, chemical-resistant and efficient laboratory device made in Russia. Designed to create a vacuum, drying and filtration under vacuum conditions, as well as pumping steam-gas-air media. The Primelab company has developed a pump in accordance with IP20 protection class. Absolutely safe: its chambers are made of fluoroplastic, the connections are covered with a fluoroplastic coating. Productivity is 38 l/min at a maximum vacuum of 6 mbar. In operating mode, the noise level does not exceed 75 dB. In Russia, the Primelab vacuum diaphragm pump PL.HM01.01.6 is subject to warranty and post-warranty service. Supplied complete with everything you need to get started.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
High-vacuum turbomolecular pump VEGA ProVac 2000
High-vacuum turbomolecular pump VEGA ProVac 2000
The complex includes: VEGA ProVac 2000 turbomolecular high vacuum pump; frequency converter; a set of mounting parts. For connection to the pre-vacuum pumping system, the pump is equipped with an ISO-KF40 exhaust flange. Pump cooling is combined. Based on the operating conditions, the complex can work both with forced air cooling and with water cooling. The working orientation in space is vertical.
Produced in: Vladimir
NVR-0,1D Plate-rotary vacuum pump
NVR-0,1D Plate-rotary vacuum pump
Pumping out steam-gas mixtures is allowed only when the gas-ballast device is open. The NVR-0,1D vacuum plate-rotary pump is manufactured in the climatic version of UHL 4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, but to be used at ambient temperature and pumped medium 283 K to 308 K (+10˚C to +35˚C). It meets the requirements of technical specifications TU 3648-021-00218526-2001, designed and manufactured taking into account the requirements of GOST R 52615-2006. The quality of electricity must meet the requrimemnts of GOST 53390-2009.
Produced in: Kazan