Search

49 products
View:
  • Selected: 0
    Applying
  • Selected: 0
    Names
  • Selected: 0
    Manufacturer
  • Selected: 1
    Made in
  • Selected: 0
    Additional
All filters
  • 11
    Applying
  • 9
    Names
  • 2
    Manufacturer
  • Made in
  • 13
    Additional
View:
49 products
STANDARD ST 41 Tablet press
STANDARD ST 41 Tablet press
Productivity, thousand tab./hour 209 Number of stations 41 Max. pressing force, tn 10 Number of threads 2 Diameter of tablets, mm 6-20 Height of tablets, mm 1.5-9 Matrix filling depth, mm 18 Rotor material Rotor die plate: steel 40x13 Filling hopper capacity, l 20(30) Stepless rotor speed change The change in the speed of rotation of the feeder is independent Supply voltage 380V, 50Hz Power consumption, kW/hour 4.18 Weight, kg 2200 Dimensions, mm 900x900x1800
POZIS
Зеленодольск
Produced in: Zelenodolsk, Tatarstan
POZIS PHARMA PH 31 Tablet press
POZIS PHARMA PH 31 Tablet press
Productivity, thousand tab./hour 160 Number of stations 31 Max. pressing force, tn 10 Number of threads 2 Diameter of tablets, mm 6-25,4 Height of tablets, mm 1.5-9 Matrix filling depth, mm 18 Rotor material steel 40x13 Filling hopper capacity, l 20(30) Stepless rotor speed change The change in the speed of rotation of the feeder is independent Supply voltage 380V, 50Hz Power consumption, kW/hour 5.78 Weight, kg 2400 Dimensions, mm 900x900x1800
POZIS
Зеленодольск
Produced in: Zelenodolsk, Tatarstan
HF-250-5 POZIS Pharmaceutical refrigerator
HF-250-5 POZIS Pharmaceutical refrigerator
from 33 050 ₽
Total volume, l. 250 Height, mm 1300 Depth without handle, mm 610 Depth with handle, mm 650 Width, mm 600 Weight, kg., no more 59 Rated power consumption, W 200 Maximum rated power, 220 W Voltage, 220 V Warranty, years 2 Final report on pre-qualification for compliance with the requirements of Good Practice of the EAEU Distribution: yes Cold storage Auto refrigerator defrosting system Temperature in the refrigerator, °C +2... +15 Accuracy of temperature maintenance ±2°C Thermal card: yes Efficiency and energy consumption Electricity consumption, kWh/day, not more than 0.82 Climate class UHL 4.2 (i.e. for moderate and cold climate) Frequency, Hz 50 Approximate dimensions of the product with packaging Net weight of the product, kg 59 Gross weight of the product, kg 63 Volume of packaging, m3 0,557 The length of the package, m 0.65 The width of the package, m 0.63 The height of the package, m 1.36
POZIS
Зеленодольск
Produced in: Zelenodolsk, Tatarstan
HF-140-1 POZIS Pharmaceutical refrigerator
HF-140-1 POZIS Pharmaceutical refrigerator
from 29 037 ₽
Total volume, l. 140 The volume of the refrigerator compartment, l. 140 Number of compressors, pcs. 1 Height, mm 910 Depth, mm without handle 610 mm; with handle 650 mm Width, mm 600 Weight, kg., no more 45 Rated power consumption, W 150 Maximum rated power, W 165 Voltage, 220 V Warranty, years 2 Final report on pre-qualification for compliance with the requirements of Good Practice of the EAEU Distribution: yes Cold storage Auto refrigerator defrosting system Temperature in the refrigerator, °C +2... +15 Accuracy of temperature maintenance ±2 Thermal card: yes Efficiency and energy consumption Electricity consumption, kWh/day, not more than 0.73 Climate class UHL 4.2 (i.e. for moderate and cold climate) Frequency, Hz 50 Approximate dimensions of the product with packaging Product net weight, kg 45 Gross weight of the product, kg 48 Volume of packaging, m3 0,397 The length of the package, m 0.65 The width of the package, m 0,63 The height of the package, m 0.97
POZIS
Зеленодольск
Produced in: Zelenodolsk, Tatarstan
 Portable kit for magnetic particle flaw detection Pole-M1
Portable kit for magnetic particle flaw detection Pole-M1
The Pole-M1 kit is used for monitoring pipelines, cranes, stanchions, beams and other ferromagnetic products, machine-building parts and workpieces for the presence of surface and subsurface defects (cracks, shells, etc.). It is designed to work in workshop, laboratory and field conditions. A permanent magnet allows you to monitor various shaped parts, welds and various products for cracks, discontinuities, shells and similar defects by magnetizing individual controlled areas or the product as a whole. The permanent magnet as part of the Polyus-M1 set of highly stable magnets with high maximum specific magnetic energy is designed to detect surface and subsurface defects in products made of ferromagnetic materials by magnetic powder or magneto-luminescent method and refers to portable specialized means of magnetic control.
NPP "ELEKTRONNYE PRIBORY"
Naberezhnye Chelny
Produced in: Tatarstan, Naberezhnye Chelny
HL-340-1 POZIS Refrigerator combined laboratory
HL-340-1 POZIS Refrigerator combined laboratory
from 56 603 ₽
Total volume, l. 400 The volume of the refrigerating chamber, l. 270 The volume of the freezer / NTO, l. 130 Number of compressors, pcs. 2 Height, mm 2080 Depth without handle, mm 607 Depth with handle, mm 650 Width, mm 600 Weight, kg., no more than 98 The weight of the refrigerator with metal doors of the upper and lower chambers, kg 91 The maximum rated power of the refrigerating chamber, W 165 The maximum rated power of the freezer, W 140 Voltage, 220 V Warranty, 1 year Final report on pre-qualification for compliance with the requirements of Good Practice of the EAEU Distribution: yes Additional transparent doors that prevent unwanted air exchange between compartments. Warranty, 1 year Low-temperature separation Rated power consumption of the freezer, W 130 Cold storage Temperature in the refrigerator, °C +2... +15 There is a height adjustment of the shelves Thermal card: yes The nominal power consumption of the refrigerator, W 150 Freezer compartment The temperature in the freezer, °C -25...-10 Efficiency and energy consumption Electricity consumption, kWh/day, no more 1.84 Climate class UHL 4.2 (i.e. for moderate and cold climate) Frequency, Hz 50 Approximate dimensions of the product with packaging Net weight of the product, kg 91-98 Gross weight of the product, kg 97-104 Volume of packaging, m3 0,876 The length of the package, m 0.65 The width of the package, m 0.63 The height of the package, m 2.14
POZIS
Зеленодольск
Produced in: Zelenodolsk, Tatarstan
HF-400-5 POZIS Pharmaceutical refrigerator
HF-400-5 POZIS Pharmaceutical refrigerator
from 47 172 ₽
Total volume, l.. 400 Number of compressors, pcs. 1 Height, mm 1950 Depth without handle, mm 610 Depth with handle, mm 650 Width, mm 600 Weight, kg., no more 86 Rated power consumption, W 250 Maximum rated power, 250 W Voltage, 220 V Warranty, years 2 Final report on pre-qualification for compliance with the requirements of Good Practice of the EAEU Distribution: yes Additional transparent doors that prevent unwanted air exchange between compartments. Cold storage Auto refrigerator defrosting system Temperature in the refrigerator, °C +2... +15 Accuracy of temperature maintenance ±2 Thermal card: yes Efficiency and energy consumption Electricity consumption, kWh/day, no more than 1.76 Climate class UHL 4.2 (i.e. for moderate and cold climate) Frequency, Hz 50 Approximate dimensions of the product with packaging Net weight of the product, kg 86 Gross weight of the product, kg 91 Volume of commodity packaging, m3 0.827 The length of the package, m 0.65 The width of the package, m 0.63 Height of the package, m 2.02
POZIS
Зеленодольск
Produced in: Zelenodolsk, Tatarstan
RBC-1 POZIS recirculator
RBC-1 POZIS recirculator
from 11 577 ₽
Capacity, m3/h 70 Bactericidal efficiency, % 95 Total power of UV radiation of bactericidal lamps, W, not less 11 Service life of UV lamps, hours 9000 Power consumption, W, 45±5 Adjusted sound power level, no more than 40 dBA Germicidal UV light lamps of the LUV35/2G11 type, with a power of 35 W 1 pc Dimensions (H*W*D), mm 406*291*211mm (with stand); 406x291x153 mm (without stand) Weight, kg, no more than 3.6 Warranty, years 2 Approximate dimensions of the product with packaging Net weight of the product, kg 3.6 Gross weight of the product, kg 4.25 Volume of packaging, m3 0.033 Length of the package, m 0,47 Width of the package, m 0,35 Height of the package, m 0,20
POZIS
Зеленодольск
Produced in: Zelenodolsk, Tatarstan
POZIS STANDARD STAMPS Tablet press
POZIS STANDARD STAMPS Tablet press
Productivity, thousand tab./hour 140 Number of stations 31 Max. pressing force, tn 10 Number of threads 1 Diameter of tablets, mm 6-25,4 Height of tablets, mm 10-16 Matrix filling depth, mm 26 Rotor material steel 40x13 Filling hopper capacity, l 50 Changing the rotation speed of the rotor with a variator The change in the rotation speed of the feeder: forced Supply voltage 380V, 50Hz Power consumption, kW/hour 4.18 Weight, kg 2200 Dimensions, mm 900x900x1800
POZIS
Зеленодольск
Produced in: Zelenodolsk, Tatarstan
HF-250-3 POZIS Pharmaceutical refrigerator
HF-250-3 POZIS Pharmaceutical refrigerator
from 31 384 ₽
Total volume, l. 250 Height, mm 1300 Depth without handle, mm 610 Depth with handle, mm 650 Width, mm 600 Weight, kg., no more 59 Rated power consumption, W 200 Maximum rated power, 220 W Voltage, 220 V Warranty, years 2 Final report on pre-qualification for compliance with the requirements of Good Practice of the EAEU Distribution: yes Cold storage Auto refrigerator defrosting system Temperature in the refrigerator, °C +2... +15 Accuracy of temperature maintenance ±2°C Thermal card: yes Efficiency and energy consumption Electricity consumption, kWh/day, not more than 0.82 Climate class UHL 4.2 (i.e. for moderate and cold climate) Frequency, Hz 50 Approximate dimensions of the product with packaging Net weight of the product, kg 59 Gross weight of the product, kg 63 Volume of packaging, m3 0,557 Length of the package, m 0.65 Width of the package, m 0,63 Height of the package, m 1.36
POZIS
Зеленодольск
Produced in: Zelenodolsk, Tatarstan
Radiation Monitoring Station Zastava-1
Radiation Monitoring Station Zastava-1
Devices of a new generation, automated stations of continuous radiation monitoring Zastava-1 are designed to organize continuous effective monitoring of the radiation situation and notification of radiation hazards. The stations have up to three independent measurement channels, which allows monitoring simultaneously in several zones. The stations support remote monitoring - they have a connection to a local computer network, Internet access.
NPP "ELEKTRONNYE PRIBORY"
Naberezhnye Chelny
Produced in: Tatarstan, Naberezhnye Chelny
HC-400-1 POZIS blood storage refrigerator
HC-400-1 POZIS blood storage refrigerator
from 56 802 ₽
Total volume, l. 400 Number of compressors, pcs. 1 Height, mm 1950 Depth, mm 610 Width, mm 600 Weight, kg., no more 72 Rated power consumption, W 300 Maximum rated power, W 315 Voltage, 220 V Warranty, 1 year Final report on pre-qualification for compliance with the requirements of Good Practice of the EAEU Distribution: yes Additional transparent doors that prevent unwanted air exchange between compartments. Cold storage Auto refrigerator defrosting system Temperature in the refrigerator, °C +2...+6 Accuracy of temperature maintenance ±2°C Thermal card: yes Efficiency and energy consumption Electricity consumption, kWh/day, no more than 1.42 Climate class UHL 4.2 (i.e. for moderate and cold climate) Frequency, Hz 50 Approximate dimensions of the product with packaging Net weight of the product, kg 72 Gross weight of the product, kg 76.5 Volume of packaging, m3 0.827 The length of the package, m 0.65 The width of the package, m 0.63 The height of the package, m 2.02
POZIS
Зеленодольск
Produced in: Zelenodolsk, Tatarstan