Rubidium frequency standard H1-1012
Rubidium frequency standard H1-1012
The Ch1-1012 frequency standard is designed for mobile applications with high requirements for dimensions, weight and power consumption as an embedded signal source of high stability in frequency measuring devices and complexes, telecommunication systems, navigation and communication systems. This device can serve as a promising substitute for quartz generators in the development of high-resolution equipment, where the accuracy characteristics of a quartz generator are no longer sufficient.
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
conductometer MARK® 602
conductometer MARK® 602
Measurement of electrical conductivity (UEP, UEP25) and salinity of aqueous media, including "ultrapure". Control of water-chemical regimes at thermal and nuclear power facilities. Specialized water treatment.Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points. Convenience and accuracy of measurement, minimum maintenance | Double automatic thermal compensation. The possibility of placing the converter unit at a remote distance from the sampling point | Up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. Programmable setpoints with a "dry contact" type output. Durable aluminum housing IP65 | The device is reliably protected from dust and moisture. Graphic indicator with backlight | Convenient data presentation format and ease of settings
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
MARK-409 Dissolved Oxygen Analyzer
MARK-409 Dissolved Oxygen Analyzer
Measurement of dissolved oxygen concentration and temperature of aqueous media, including deaerated ones. Continuous monitoring of water-chemical regimes at thermal and nuclear power facilities. Two channels Freely programmable measurement ranges. The possibility of independent measurements at two points. Convenience and accuracy of measurement, minimum maintenance Automatic temperature and barocompensation. Automatic air oxygen calibration. Long-lasting sensor The service life of the sensor is at least 10 years. The possibility of placing the converter unit at a remote distance from the sampling point Up to 100 meters. Communication with external devices Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port, MODBUS RTU exchange protocol. Programmable setpoints with a "dry contact" type output. Durable IP65 aluminum housing The device is reliably protected from dust and moisture. Graphic indicator with backlight Convenient data presentation format and ease of settings
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Na-meter MARK® 1002
Na-meter MARK® 1002
Measurement of the activity of sodium ions (CNa) and the temperature of aqueous media. Control of parameters of water-chemical regimes at thermal and nuclear power facilities.Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points of CNa or pNa, temperature. Convenience and accuracy of measurement, minimum maintenance | Measurements from 0.01 CNa. The typical error is 6%. Long intergrading interval (up to 6 months). Automatic thermal compensation. Automatic dosing device of the alkalizing reagent. No capacity with KCl. Calibration by one solution | If necessary, three-point calibration is possible. "Active" sensor unit | The digital communication channel of the sensor with the converter unit is up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Programmable settings of the "dry" contact type.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
pH meter MARK® 903
pH meter MARK® 903
Measurement of the activity of hydrogen ions (pH, pH25), ORP, EMF and temperature of aqueous media. Operational control of parameters of water-chemical regimes at thermal and nuclear power facilities, in accordance with CO 153-34.37.303. Convenience and accuracy of measurement | Automatic temperature compensation. Automatic recognition of buffer solutions. Measurement modes | pH or pH25 and temperature. EMF and temperature. pH measurement in flow and immersion modes | The flow-filling module MPN 901/903 is included. Self-diagnosis | Non-volatile electronic notebook | The ability to record up to 500 measurement groups in User-named folders. USB port, software included | The ability to create and manage a data archive on a PC. Graphic indicator with backlight | Indication of readings in a user-friendly format. Ease of settings. IP65 | Compact sealed device is reliably protected from dust and moisture. Low power consumption | Up to 600 hours of continuous operation from a set of AA elements.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Frequency comparator CHK7-1011
Frequency comparator CHK7-1011
Frequency comparators CHK7-1011 and CHK7-1011/1 can also be used as frequency and time standards with frequency correction based on GLONASS/GPS signals as sources of highly stable signals in various frequency measuring systems. Comparators have a built-in device for processing measurement data based on a microcomputer, which provides statistical processing of the results of frequency and time measurements, and a device for displaying information based on a color TFT display. The built-in diagnostic system allows you to quickly determine the operability and condition of the main comparator devices with information output to the built-in display screen. Comparators are available in three versions and differ in composition and functions performed. Comparators have a basic set of devices (modules), including a frequency comparator, a power supply module and a device for processing and displaying information based on a microcomputer and a color TFT display. The frequency comparator CHK7-1011 has a built-in SRNS receiver and a highly stable rubidium frequency standard Ch1-1014 with the function of correcting the actual frequency value by signals from satellite radio navigation systems GLONASS or GPS. The comparator forms its own time scale with the ability to synchronize on any external time scale received by the SRNS receiver built into the device. The device has two modes for measuring the deviation of the generated time scale: from the time scale of the built-in SRNS receiver and from the external time scale. Information about the current time received from the SRNS receiver is displayed on the comparator display screen, and is also transmitted to the consumer via the RS-485 interface. All the above-mentioned features make the frequency comparator CHK7-1011 a unique measuring device in the field of frequency and time measurements. The frequency comparator CHK7-1011/1 has a highly stable rubidium frequency standard Ch1-1013 and can be used as a frequency and time standard as a source of highly stable signals in various frequency measuring systems. The frequency comparator CHK7-1011/2 does not include any additional devices. To carry out measurements with it, it is necessary to use a highly stable signal of the reference frequency from an external RF or hydrogen frequency standard. For the convenience of users, apart from the keypad, they can also exercise control of the functions of the devices with a mouse-type manipulator included in the delivery package. Comparators provide access to measurement data over an Ethernet network.
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
Rubidium Ch1-1014 Frequency Standard with GPS/GLONASS Signal Receiver Module
Rubidium Ch1-1014 Frequency Standard with GPS/GLONASS Signal Receiver Module
The signals of the navigation receiver's second mark and the RF available for the customer`s use are generated simultaneously on two high-frequency outputs of the receiver board. In the presence of stable reception of signals from satellites of the GLONASS and GPS radio navigation systems, the board ensures the operation of the RF in the frequency binding mode according to the signals of the second timestamp (the so-called “disciplined” rubidium frequency standard mode) with a relative error of the actual value of the RF frequency of no more than ± 5.0.10-12.
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
MARK-409T Dissolved Oxygen Analyzer
MARK-409T Dissolved Oxygen Analyzer
Measurement of dissolved oxygen concentration and temperature of aqueous media, including deaerated ones.Convenience and accuracy of measurement | The measurement error is ±(0.001 + 0.035 *A) mg/dm3, (A is the measured value). The ability to work on small flows (from 25 ml / min). Routine maintenance 1 time per year. Highly stable sensor | High reaction speed. Sealed heavy-duty hydrophobic membrane. Increased mechanical strength of the structure. Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points. The possibility of placing the converter unit at a remote distance from the sampling point | Up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Hydropanel GP 409 T | The possibility of placing the measuring complex on a single panel. The supply lines are stainless steel. Routine maintenance and calibration of the sensor – without interrupting the flow. Continuous monitoring of water-chemical regimes at thermal and nuclear power facilities.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod