Measuring antenna P6-62
Measuring antenna P6-62
1 supp.
Technical specifications: Frequency range (300-1000) MHz SWR < 2 The limit of permissible error of the antenna coefficient, not more than ± 2.0 dB Orthogonal polarization signal level -20 dB Ambient air temperature from - 50 to + 60 Relative humidity of 95 % at + 35 ° C Overall dimensions (HxWxD) 400x145x150 mm Weight 1 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Immitance Broadband Analyzer E7-29
Immitance Broadband Analyzer E7-29
Technical specifications: Extended frequency range 50 kHz–15 MHz The basic error is ±0.2 % The level of the measuring signal is 40 mV – 1 V s.c . Offset voltage (0 – 40) V The discreteness of the operating frequency setting is 1 Hz Graphical analysis of measured values in a given frequency range USB 2.0 interface -100 C to 400 C; humidity 90% at 300 C Dimensions, weight: 270x134x320 mm, 5 kg Power supply ~230 V, 20 VA
MNIPI
Minsk
Produced in: Belarus, Minsk
MKS‑AT6101DR SPECTROMETER (STATIONARY VERSION)
MKS‑AT6101DR SPECTROMETER (STATIONARY VERSION)
▪ Measurements without sampling in geometry 4π ▪ Intelligent detection unit in an airtight container ▪ The possibility of further detailed processing of the measured data using specialized software
Produced in: Belarus, Minsk
DOSIMETRIC GAMMA RADIATION DETECTION UNITS
DOSIMETRIC GAMMA RADIATION DETECTION UNITS
Gamma radiation Detection Units (BDKG-04, BDKG-22, BDKG-23, BDKG-23/1, BDKG-24, BDKG-25, BDKG-30, BDKG-32, BDKG-35, BDKG-36, BDKG-38, BDKG-204, BDKG-224, BDKG-230) are designed to use as part of stationary and mobile radiation monitoring posts and robotic devices for ground, aviation and marine applications.
Produced in: Belarus, Minsk
X‑RAY AND GAMMA RADIATION DOSIMETERS DKS‑AT1121, DKS‑AT1123
X‑RAY AND GAMMA RADIATION DOSIMETERS DKS‑AT1121, DKS‑AT1123
Measurements in wide ranges of capacities doses and energies Measurement of dose rate and duration of exposure during short-term radiation from 0.03 s Measurement of the average dose rate of pulsed radiation with a pulse duration of 10 ns (AT1123) The possibility of remote measurements using a remote control The possibility of stationary location with external audible and visual alarms with "dry" contacts for controlling actuators The possibility to connect to a PC for organizing a continuous monitoring system with a documentation function
Produced in: Belarus, Minsk
Generator G3-131
Generator G3-131
Technical specifications: Frequency range, from 2 Hz to 2 MHz Frequency setting error, ± 1 % Signal amplitude: - at a load of 600 ohms , at least 5 V at least 10 V Smooth signal attenuation, at least 20 dB Frequency instability: - in 15 minutes - for 180 minutes, no more than 0.1% no more than 0.5 % Harmonic coefficient: - in the frequency range from 10 Hz to 20 Hz - in the frequency range sv. 20 Hz to 200 kHz - in the frequency range of 200 kHz to 2 MHz, not more than 0.5% not more than 0.2% not more than 1 %
MNIPI
Minsk
Produced in: Belarus, Minsk
Voltmeter V7-77
Voltmeter V7-77
Technical specifications: DC voltage , Measuring range, 10 mv-1000V Measurement error, ± (0.05% +4 E.M.R.) AC voltage , Measuring range, 1 mV - 750 V Measurement error, ± (0.5% +4 E.M.R.) Frequency range, 20 Hz- 100 kHz Direct current , Measuring range, 0.1 µA - 10 A Measurement error, ± ( 0.25% +4 E.M.R.)
MNIPI
Minsk
Produced in: Belarus, Minsk
Connecting device UP-4
Connecting device UP-4
Technical specifications: Residual capacity when working with immitance meters < 1 pF Residual inductance when working with immitance meters < 0.5 µgn Residual resistance when working with immitance meters < 0.05 ohms Maximum input voltage ±60 V Distance between measuring contacts from 0 to 6 mm Length 1050 mm Weight 160 g
MNIPI
Minsk
Produced in: Belarus, Minsk
Voltmeter V7-82
Voltmeter V7-82
Technical specifications: DC voltage , Measuring range, 10 mv-1000V Measurement error, ± 0.01% AC voltage , Measuring range, 1 mV - 700 V Measurement error, ± 0.4% Frequency range, 20 Hz- 1 MHz Direct current , Measuring range, 0.2 µA - 10 A Measurement error, ± 0.15%
MNIPI
Minsk
Produced in: Belarus, Minsk
RADIATION PEDESTRIAN MONITOR MPP‑AT930
RADIATION PEDESTRIAN MONITOR MPP‑AT930
▪ Rapid adaptation to changes in the radiation background ▪ Audible and light alarms when gamma radiation is detected ▪ Mobility and the possibility of forming passages ▪ Self-control of components in the process of work ▪ The possibility of continuous or episodic radiation monitoring ▪ The possibility to work from a 230V, 50Hz network or from a built-in rechargeable battery Compliance with the international standard IEC 62244:2006 Stationary radiation monitors for the detection of radioactive and special nuclear materials at state borders
Produced in: Belarus, Minsk