Immitance meter E7-25
Immitance meter E7-25
Technical specifications: Conductivity (Gp) - 10-11 – 10 Cm Resistance (Rs, Rp, Xs, |Z|) 10-5 – 109 Ohms Capacity (Ss, Cp) - 10-15 – 1 F Inductance (Ls, Lp) 10-11 – 104 Gn Dobrotn.(Q), loss angle tangent (tg) 10-4 – 104 Phase shift angle of the resistance set -180° – +180° Leakage current (I) - 10-7 – 10-3 A Measurement error - ± 0.15 % Operating frequencies – 25 Hz – 1 MHz Power consumption - 10 VA Overall dimensions - 225x110x35 mm Weight - 0.8 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
HUMAN RADIATION SPECTROMETER SKG‑AT1316
HUMAN RADIATION SPECTROMETER SKG‑AT1316
Calculation of the expected effective dose of internal radiation per year from incorporated 137Cs and 134Cs Flexible software control of the spectrometer functions, the formation of a database and a report on the results of the survey Express control capacity - 15 people per hour The possibility of sharing AT1316(AT1316A) and AT1322(AT1322/1) The possibility of accommodation in a minibus as part of a mobile radiation control laboratory
Produced in: Belarus, Minsk
HUMAN RADIATION SPECTROMETER SKG‑AT1316A
HUMAN RADIATION SPECTROMETER SKG‑AT1316A
Deliveries in the CIS are carried out by LLC NPP RADIKO 249035, Kaluga region, Obninsk, Marx Avenue, 14 Phone: 8(48439) 4-97-16, 4-97-18 / Fax: 8(48439) 4-97-68 E-mail: main@radico.ru / Web site: http://www.radico.ru Control of exceeding the threshold value of the total activity of radionuclides 51Cr, 54Mn, 58Co, 59Fe, 65Zn, 95Nb, 100mAg, 103Ru, 124Sb, 141Ce, 144Ce in the lungs; Flexible software control of the spectrometer functions, the formation of a database and a report on the results of the survey Express control capacity - 15 people per hour The possibility of sharing AT1316(AT1316A) and AT1322(AT1322/1) The possibility of accommodation in a minibus as part of a mobile radiation control laboratory
Produced in: Belarus, Minsk
DOSIMETERS‑RADIOMETERS ISS‑AT1125, ISS‑AT1125A
DOSIMETERS‑RADIOMETERS ISS‑AT1125, ISS‑AT1125A
- Measurement of the dose and power of the ambient equivalent of the dose of X-ray and gamma radiation; - Control of the content of 137Cs in samples placed in a Marinelli vessel with a volume of 0.5 liters, both with and without the protection unit (BZ); - Measurement of the flux density of alpha and beta particles from contaminated surfaces (external detection unit BDPS-02); - Search and detection of X-ray and gamma radiation sources. High sensitivity Spectrum display mode when connected to a PC
Produced in: Belarus, Minsk
DOSIMETER‑RADIOMETER MKS‑AT1117M
DOSIMETER‑RADIOMETER MKS‑AT1117M
Depending on the set of detection units, the device is designed to measure: - ambient dose equivalent and ambient dose equivalent power of X-ray, gamma and neutron radiation; - kerma and kerma power in the air; - the directional dose equivalent and the power of the directional dose equivalent of continuous X-ray and gamma radiation; - the flux and fluence densities of alpha and beta particles from contaminated surfaces; - the flux and fluence densities of neutron radiation with a known energy distribution; - surface activity and number of decays of 239Pu and 90Sr + 90Y; - operational search for sources of ionizing radiation and radioactive materials.
Produced in: Belarus, Minsk
IPPP-1 Semiconductor Device Parameter Meters
IPPP-1 Semiconductor Device Parameter Meters
Technical specifications: 4-channel automated system for measuring the parameters of semiconductors (including test structures on plates) Study of the VAC of 2, 3, 4-pole Parameters of each channel Source/meter:- U: ±2 V, ±30 V (200 mA), ±120 V (±10 mA), I: ±20, ±200 nA, ±2, ±20, ±200 Ma, ±2, ±10mA, (±120V), ±20, ±200 mA (±30V) Source and meter error U, I ± 0.5% Sensitivity of the U/I meter: 10 mv/ 0.1 pA Graphs, tables, texts, databases RS-232C interface, computer software Dimensions, weight: 450x266x444 mm, 23 kg Power supply: ~220V, 120 VA
MNIPI
Minsk
Produced in: Belarus, Minsk
Immitance meter E7-30
Immitance meter E7-30
Technical specifications: Wide frequency range 25 Hz–3 MHz Capacity (10-15-1) F Inductance (10-11-104) Gn Resistance (10-5-109) Ohms Conductivity (10-11-10) Cm Modulus of complex resistance (10-5-109) ohms Reactance (10-5-109) Om Phase shift angle -90° – +90° Q factor, loss factor 10-4-104 Leakage current (10-8-10-2) A The error is ±0.1% Offset voltage 0 – 40 V (external up to 120 V) Measuring signal level (0.005 – 1) V RS-232C, USB 2.0 interfaces Mathematical processing of measurements Dimensions, weight: 134x270x320 mm, 4 kg Power supply ~230 V, 20 VA
MNIPI
Minsk
Produced in: Belarus, Minsk
SRK‑AT2327 ALARM METER WITH INFORMATION BOARD
SRK‑AT2327 ALARM METER WITH INFORMATION BOARD
Logging data on dose rate levels and exceeding threshold levels The possibility of placing the detection unit and the temperature sensor at a distance of up to 1 km separately from the scoreboard Additional protection from direct exposure to precipitation
Produced in: Belarus, Minsk
SPECTROMETRIC GAMMA RADIATION DETECTION UNITS
SPECTROMETRIC GAMMA RADIATION DETECTION UNITS
Gamma radiation detection units (BDKG-05M, BDKG-11M, BDKG-19M, BDKG-201M, BDKG-203M, BDKG-205M, BDKG-211M, BDKG-219M) for use as part of stationary and mobile radiation monitoring posts and robotic devices for ground, aviation and marine applications
Produced in: Belarus, Minsk
RADIATION PEDESTRIAN MONITORS MPP‑AT920V, MPP‑AT920R (SRK‑AT2327)
RADIATION PEDESTRIAN MONITORS MPP‑AT920V, MPP‑AT920R (SRK‑AT2327)
Rapid adaptation to changes in the radiation background Audible and light alarms The possibility to create a network of MCI (up to 32) under the control of a PC and specialized software Mobility and the possibility to organize the control of passages in a short time High reliability and self-control Backup power supply
Produced in: Belarus, Minsk