Flame Photometric(FD)
Flame Photometric(FD)
Selective detector for phosphorus and organosulphide compounds. It is used mainly for the analysis of sulfur-containing substances (hydrogen sulfide, mercaptans, thiophenes, etc.). The sensitivity for sulfur reaches 0.1. ppm. In addition, PFD has sufficient sensitivity and selectivity to compounds containing nitrogen, boron, tin, chromium, selenium, germanium, as well as CO, POPS, MgOx, $02, Ma, NOT C52. The selectivity of 5-containing compounds to hydrocarbons is 105. Technical characteristic: 8,0*10-13 g5/s by sulfur 1.0*10`13 g/s for phosphorus
Produced in: Yoshkar-Ola, Mari El
Flame Ionization (PID) for chromatograph
Flame Ionization (PID) for chromatograph
The most common, universal detector that is suitable for the analysis of a wide range of organic compounds. The sensitivity depends mainly on the number of carbon atoms. In combination with a methanator, it allows the analysis of carbon oxides at the level of 0.1 Rt. The level of fluctuation noise is up to 50 MV, the maximum signal is up to 2500 V. Technical characteristic: 1.2*10712 gs/s for hydrocarbons
Produced in: Yoshkar-Ola, Mari El
HIGH PRESSURE GAS FILTER UNIT
HIGH PRESSURE GAS FILTER UNIT
A block of gas filters for lines with a pressure of up to 15 MPa. The volume, length, connection dimensions, type of connections with supply pipelines are specified when ordering.
Produced in: Yoshkar-Ola, Mari El
META-CHROME AIR COMPRESSORS
META-CHROME AIR COMPRESSORS
The KOV-4 type air compressor is designed to supply flame detectors of gas chromatographs with air. Technical specifications: Capacity, at least, l/min 3 Outlet air pressure, 0.25+5 MPa% Pressure stability at constant flow rate, not more than 0.0007 MPa Engine power consumption, max, VA 100 Receiver volume, l 9 Noise level, no more, 60 dBa Weight, not more than, kg 19 Overall dimensions (width×depth×height), not more than, mm 235×755×440 Single-phase mains voltage 220 V, 50 Hz
Produced in: Yoshkar-Ola, Mari El
Thermionic (TID)
Thermionic (TID)
Selective detector for organophosphorus and nitrogen compounds. It is also sensitive to compounds containing C, Az, but to a lesser extent. The sensitivity depends on the number of heteroatoms in the molecule. Selectivity to hydrocarbons is 104 for nitrogen, and 105 for phosphorus Technical characteristic: 2.0*10-13 m/s nitrogen 1.5*10`14 g/s for phosphorus
Produced in: Yoshkar-Ola, Mari El
DISPENSER "EVEN 4000"
DISPENSER "EVEN 4000"
The dispenser "DAZH 4000" is designed for automatic insertion of liquid samples into the evaporator of the gas chromatograph, provides: control from the software, setting variable parameters of algorithms for washing and sample entry, storing the operating parameters of the dispenser in the method. Technical characteristics: The number of vials in the carousel, pcs up to 30 The volume of installed vials, ml 0.1-2ml Number of injections from one vial 1-99 Replaceable syringes in volume, ml 10, 100, 250, 500 The volume of the injected sample, ml : from 0.01 to 500 The discreteness of setting the sample volume, µl: from 0.01 to 1 Sampling and insertion rate, µl/s: from 0.01 to 5000 The speed of needle insertion into the evaporator, discret 3 Immersion depth in the vial and evaporator, variable up to the length of the syringe needle, mm 1 – 99 The discreteness of the dive depth setting, mm 0,1 The number of pumping during sampling 0-15 Number of solvent washes 0-15 Needle exposure time in the evaporator, sec 0-99 The discreteness of setting the needle shutter speed, sec 1,0 Sample input modes Simple insertion, Sandwich, Solvent sandwich, Sandwich with internal standard Flushing mode From the vial Supply voltage, V (frequency, Hz) 220 (50) Power consumption, W 154 Weight, kg, no more 2,9 Overall dimensions, mm 175x270x420 Communication with the computer Ethernet
Produced in: Yoshkar-Ola, Mari El
GAS FLOW REGULATOR
GAS FLOW REGULATOR
The flow regulator consists of the following parts: Body. It includes a connector for connection to the control controller and fittings for connecting the input and output gas lines. Calorimetric converter. Due to the heating of the gas along the flow section, the temperature difference is determined. The actuator (solenoid valve). The control board. A system of elements responsible for converting the signals that the user submits. TECHNICAL CHARACTERISTICS OF RD The gas pressure at the inlet is (0.4 + 0.04) MPa. Ranges of working gas flow rates — from 5 to 800 ml/min. The ability to specify the type of gas (nitrogen, helium, hydrogen, argon, air). Pressure ranges — from 0.001 to 0.40 MPa with a discreteness of 0.0001 MPa. The deviation of the carrier gas flow rate from the average value is + 1.5% in the flow range from 50 to 100 ml/min and + 0.5 ml/min in the flow range from 3 to 50 ml/min. Relative deviation of the average steady-state gas flow rate from the set value in the range from 3 to 100 ml/min: + 2.5%, but not less than 0.5 ml/min; from 100 to 200 ml/min.: + 5%; from 200 to 800 ml/min.: + 10%. The gas pressure at the inlet is (0.4 + 0.04) MPa. The deviation of the regulated output pressure of the regulator from the set value is not more than 1%.
Produced in: Yoshkar-Ola, Mari El
PYROLYZER
PYROLYZER
The pyrolytic gas chromatography method is widely used in the study of polymer materials, plastics, rubbers, rubbers, paints and other high-molecular compounds of natural and artificial origin. The method is based on thermal decomposition of sample samples in an inert medium (without oxygen access), followed by chromatographic separation and analysis of the formed volatile compounds. Thus, the resulting pyrogram allows us to judge the composition of the original sample. Pyrolysis is also used in geochemical studies. Technical specifications The volume of the capsule is 56 ml. Pyrolysis temperature — from 200 to 1000 °C. The error of maintaining the temperature is not more than 1.0 ° C. The heating time of the sample to the pyrolysis temperature is no more than 2 seconds. The cooling time of the capsule when moving from the hot zone to the cold zone after pyrolysis is no more than 10 seconds. The time of continuous operation in the pyrolysis mode is no more than 60 seconds. Electric power supply from the AC network with voltage (220index) V, frequency (50 ± 1) Hz. Power consumption — no more than 100 VA. Overall dimensions of the control unit (width ×depth×height) — 210×190×100 mm. Overall dimensions of the input node (width× depth×height) — 90×135×160 mm. The weight of the control unit is not more than 2.5 kg. The weight of the input node is not more than 0.9 kg.
Produced in: Yoshkar-Ola, Mari El
Gas chromatograph Crystallux-4000m
Gas chromatograph Crystallux-4000m
The gas chromatograph "Kristallux-4000M" is fully automated, starting from sample input and ending with chromatographic information processing, including the functions of automatic temperature control of thermostats, flow rates and pressure of the carrier gas (EUPG system), auxiliary gases, automatic ignition of detectors, flame burning control during operation, measurement of detector signals using Gorenje 24-bit ADC. Technical specifications: The detection limit of PID is 1,1x10-12 gS/s for h-hydrocarbons 1,1x10-12 gS/s for propane. The detection limit of DTP1.7x10-14 g/s for lindane 3.9x10`15 g/s for lindane (micro-ED) The detection limit of EZD1x10`13 grus for phosphorus in metaphos 8x10`13 g5/s for sulfur in metaphos or hydrogen sulfide PFD detection limit 1.5x10`14 g/s for phosphorus in metaphos 3x10`13 GM/s for nitrogen in azobenzene Detection limit of TID2x10`10 g/ml by hydrogen The detection limit of TcD is 5x10`13 g/s for benzene The detection limit of the FEED is 3x10`13 g/s for carbon in methane 3x10`13 g/s for carbon in methane Detection limit GID500:1 (M7-801) with the introduction of 1x10`12 g / ml of octafluoroaphthalene The signal-to-noise ratio of MSD 1500:1 (Maestro-oMS) when entering 1x10`12 g / ml of octafluoroaphthalene Linear dynamic range of PID x1*107 Linear dynamic range DTP1*108 The volume of the column thermostat is 14 (19)l The temperature of the column Current.Wednesday +3 °C to +400 °C (by special order up to 450 °C) (by special order from -10°C with use. cold. ust-ki)(by special order from -100 °C. with use. liquid, no.) The discreteness of the temperature setting is 0, ° C Temperature stability 0.01 °C Temperature programming speed 0t 0.1 to 125 °C/min (by special order up to 150 °C/min) The number of isotherms is not less than 30 The cooling rate of the column thermostat is from 400 to 50 °C3.3 min. The maximum temperature of the detector and evaporator is 450 °C Carrier gas consumption from 0 to 100 ml/min.(by special order up to 500 ml/min.) Carrier gas pressure (for capillary column) from 0 to 0.40 Mpa (by special order up to 1 MPa) The maximum inlet gas pressure on a special order is 0.5 MPA 1.25 MPA Hydrogen consumption 0-500 Air consumption 0-1000 Overall dimensions (width x depth x height) 550%500*500 mm Weight 39 kg Electric power supply from AC mains voltage (220.2) V, frequency (50 +1) Hz The maximum power consumption (in steady-state mode) is 900 VA.
Produced in: Yoshkar-Ola, Mari El
METERING VALVE FOR GAS SAMPLES
METERING VALVE FOR GAS SAMPLES
The metering valve for the introduction of gas samples is designed for the introduction of gas under excessive pressure into the chromatograph. Cranes differ in the number of moves (4, 6, 8, 10, 12) and have two provisions "Selection" — "Analysis". In addition to dosing, cranes can be used to switch chromatographic columns, elements of gas circuits, etc. The tap can be installed either on the side panel of the chromatograph, or directly into the analytical module instead of, or together with the evaporator of the chromatograph, while it is used as a back-purge tap or for hot sample entry. Additionally, the tap for hot entry can be equipped with heated pipelines. technical specifications The dose volume is from 0.25 to 5.0 ml (at the request of the consumer, the dose volume can be increased to 10 ml and reduced to 0.1 ml). The maximum temperature of the tap is no more than 160 °C. The pressure in the crane line is not more than 0.48 MPa. The angle of rotation of the crane handle — depending on the number of strokes.
Produced in: Yoshkar-Ola, Mari El
Thermal Conductivity Detector(accident)
Thermal Conductivity Detector(accident)
It is used to determine hydrogen, oxygen, CO and combustible hydrocarbon gases, and its sensitivity to these compounds is higher than the sensitivity of an accident. The most widespread TCD was obtained for the analysis of hydrogen and oxygen, tk. its sensitivity to them is almost an order of magnitude higher than that of an accident. The principle of operation is based on fixing the thermal effect of catalytic combustion of the sample on the surface of the platinum filament. Technical characteristic: 1.8*10`10 g/ml of hydrogen
Produced in: Yoshkar-Ola, Mari El
SYRINGE FILLING DEVICE
SYRINGE FILLING DEVICE
When analyzing gases dissolved in transformer oil using the ARP method (equilibrium vapor analysis), it is necessary to first fill a syringe with transformer oil with a carrier gas, and then, after achieving an equilibrium distribution of gases dissolved in oil between the liquid and gas phases, introduce the gas phase into the chromatograph (blow out the doses of the chromatograph dispenser tap). Moreover, the operations of filling the syringe and entering the sample are performed without air access. When filling the syringe, it is possible to fix the syringe stem at a certain volume. technical specifications The volume of syringes is 20 or 50 ml. The pressure at the outlet of the syringe filling line with argon is 0.5 atm. The range of ratios of volumes of the gas phase and oil (Vg/Vm) is from 0 to 1.5.
Produced in: Yoshkar-Ola, Mari El