Second Mark Shaper Module
Second Mark Shaper Module
Pulse duration: ......10-15 microseconds The duration of the leading edge of the pulse:......no more than 20 ns Pulse amplitude: ...... at least 3V at a load of 50 ohms
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
KRP-UR Mobile radiographic cabinet (Fluorograph)
KRP-UR Mobile radiographic cabinet (Fluorograph)
The cabinet is designed for operation at outdoor air temperatures from minus 40°C to plus 40°C.
Produced in: Podolsk
Frequency comparator CHK7-51
Frequency comparator CHK7-51
Mathematical processing of the measurement makes it possible to determine and display on the indicator board the relative systematic change in frequency, the average relative value of the frequency difference, the RMS relative frequency deviation, the RMS relative two-sample frequency deviation.
NNPO im. M.V.Frunze
Nizhny Novgorod
Produced in: Nizhny Novgorod
Model 130 Profilometer
Model 130 Profilometer
Measurement of roughness parameters Ra; Rz; Rmax; Rp; Rv; Rq; Sm; S; la; lq; tp; Lo; D; da; dq, etc., viewing the profilogram and measuring the size of inhomogeneities Tracing length: 0.5mm – 40 mm Measurement range according to Ra: 0.012 – 50mkm Degree of accuracy 1 (error 2%) Work inside the vestibule > 3mm
Produced in: Moscow, Zelenograd
Scanning probe microscope SMM-2000
Scanning probe microscope SMM-2000
Viewing and measuring grains and defects in the structure of materials, resolution to atoms (Nobel Prize in 1986), replacement of metal-graphic and electron microscopes Increase: from x2 thousand to x10 million. Measuring range: 0.2 nm to 30 microns All basic (STM, contact and vibro-AFM) modes, and more than 25 extras.modes
Produced in: Moscow, Zelenograd
Nitrogen traps
Nitrogen traps
Nitrogen traps are designed for use in various vacuum systems in order to prevent the ingress of vapor gases and various organic compounds from high-vacuum and pre-vacuum pumps into the vacuum chamber (system) following in the reverse flow, as well as to protect vacuum units from organic substances present in the vacuum volume.
NPO "Gelikon"
Saint Petersburg
Produced in: Saint Petersburg
Non-standard vacuum testing equipment
Non-standard vacuum testing equipment
For scientific and industrial applications.
NPO "Gelikon"
Saint Petersburg
Produced in: Saint Petersburg
Helium mass-spectrometric leak detector TI1-50M “HeliTest” from NPO “Helikon”
Helium mass-spectrometric leak detector TI1-50M “HeliTest” from NPO “Helikon”
The helium leak detector TI1-50M is a universal highly sensitive device designed to test the tightness of various systems and objects that allow pumping out the internal cavity, as well as those filled with helium or a mixture containing helium, and detect (localize) places of leakage (leaks). Specifications: Measuring range at the leak detector inlet, Pa•m3/s from 5•10-13 to 1•10-5; Range of indications when working by probe method, Pa•m3/s from 1•10-9 to 1•10-5; Time to enter the readiness mode for measurements, no more than, min 5; AC supply voltage, V, Hz 220±10%, 50±1; Power consumption, VA 1200; Overall dimensions (WxHxD), no more than, mm 480x470x390; Weight, no more than, kg 40; Average time to metrological failure, h 15000;
NPO "Gelikon"
Saint Petersburg
Produced in: Saint Petersburg
Halogen leak detector "GTI-8"
Halogen leak detector "GTI-8"
It is designed to search for leaks of freons and other halogen-containing gases, for example, gas, in working equipment, and when testing systems, including cable ones, for tightness. The GTI-8 halogen leak detector also allows detecting an increase in the concentration of such gases in the room or near the controlled object. Technical characteristics of the leak detector "GTI-8" Parameter Sensitivity of the leak detector GTI-8, m3 Pa/sec., not less 1.0 - 5.3/10e-7 Time constant, sec., no more 3 Compensation of the initial sensor current Availability Automatic background signal compensation Availability Adjustable trigger threshold Availability Food ~220V, 50Hz (14.8V for GTI-8B) For modification of GTI-8B, continuous operation time, hour, at least 8 Operating mode setting time, min, no more 5
NPO "Gelikon"
Saint Petersburg
Produced in: Saint Petersburg
Kepler-10b Vacuum furnace
Kepler-10b Vacuum furnace
Horizontal vacuum resistance furnaces are designed for carrying out various technological processes in high vacuum at temperatures up to 1600 degrees. The furnace can be used in electronic, radio engineering, aviation, rocket and other industries. The main areas of application are the technological processes of annealing, quenching, degassing and sintering.
NPO "Gelikon"
Saint Petersburg
Produced in: Saint Petersburg
Vacuum and crimping chambers
Vacuum and crimping chambers
Vacuum chambers can be used: for drying materials (low vacuum), testing spacecraft, during experiments on plasma retention and antimatter production, as elements of charged particle accelerator systems and systems for applying thin films. Vacuum chambers can be used: for drying materials (low vacuum), testing spacecraft, during experiments on plasma retention and antimatter production, as elements of charged particle accelerator systems and systems for applying thin films.
NPO "Gelikon"
Saint Petersburg
Produced in: Saint Petersburg