Oscilloscope S1-176
Oscilloscope S1-176
It is intended for the study of periodic electrical signals by visual observation and measurement of their amplitude and time parameters on the scale of the CRT screen in the frequency band 0-50 MHz, as well as for monitoring the parameters of two- and three-pole devices using a component tester. Technical specifications: Number of channels 2 Bandwidth 0 - 50 MHz Deviation coefficients of 2 mV/div - 20 V/div (step1-2-5) Installation error ± 3%, ± 4% with a 1:10 divider Rise time of PH <= 7 nsec Input impedance is 1 mOhm/25 pF, with a divider of 1:10 - 10 mOhm/23 pF Harsh operating conditions (-10°C to +40°C) Bandwidth 0 - 50 MHz Two channels Indication of deviation and sweep coefficients on LED matrices Tenfold stretching of the sweep Calibrator 0.6 V, 1 kHz (± 1%) X-Y mode Built-in Component Tester Screen 80x100 mm Weight 6,8 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Picoammeter A2-4
Picoammeter A2-4
System meter of small currents. The device allows to make measurements in almost the entire range of currents. The picoammeter is characterized by high performance, which is important for its use as part of automated measuring systems. Technical specifications: Current measuring range 1x10-14 - 1x10-2 A Error for the range 10-11, 10-10 ±[0.5+0.025(lk/lx-1)]% for the range 10-9, 10-8 ±[0.25+0.01(lk/lx-1)]% for the range 10-7, 10-6,10-5, 10-4,10-3, 10-2 ±[0,1+0,01( lk/lx-1)]% The time of setting the readings is 2x10-2 - 2x10-5 s Supply voltage 230 (±20) V, frequency 50 (± 0.5) Hz Power consumption 10 VA Overall dimensions (HxWxD) 105x284x366 mm Weight 3.5 kg Operating temperature 5 - 40 °C Humidity 80% at 25 °C
MNIPI
Minsk
Produced in: Belarus, Minsk
Immitance Broadband Analyzer E7-28
Immitance Broadband Analyzer E7-28
Technical specifications: Extended frequency range 25 Hz–10 MHz The basic error is ±0.1 % The level of the measuring signal is 5 mV – 1 V S.K.z. Offset voltage (0 – 40) V The discreteness of the operating frequency setting is 1 Hz Graphical analysis of measured values in a given frequency range USB 2.0 interface
MNIPI
Minsk
Produced in: Belarus, Minsk
Measuring antenna P6-62
Measuring antenna P6-62
1 supp.
Technical specifications: Frequency range (300-1000) MHz SWR < 2 The limit of permissible error of the antenna coefficient, not more than ± 2.0 dB Orthogonal polarization signal level -20 dB Ambient air temperature from - 50 to + 60 Relative humidity of 95 % at + 35 ° C Overall dimensions (HxWxD) 400x145x150 mm Weight 1 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
FAC286 lenses
FAC286 lenses
Technical specifications Material: S-TIH53 (Ohara) Length, mm: 12 Height, mm: 1.0±0.02 Thickness, mm: 0.36±0.01 Refractive index, mm: 1.823 Effective focal length, mm: 0.29 Rear focal length, mm: 0.09 Transmission, %: >99.5 Power within the angle ± 2.3 mrad, %: >85 Antireflection coating, nm at one of the wavelengths from the range: 400-1500 Numerical aperture: 0.5 Surface quality λ = 633, nm: λ/4
INZHEKT
Saratov
Produced in: Saratov
Caesium cell D=5mm, L=13mm
Caesium cell D=5mm, L=13mm
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
Green DPSS Laser 532 nm KLM-532/SLN-x
Green DPSS Laser 532 nm KLM-532/SLN-x
DPSS lasers of the KLM-532/SLN-x series are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
BTS 200/400 Lenses
BTS 200/400 Lenses
Technical specifications Material: S-TIH53 (Ohara) Length, mm: 12 Height, mm: 1.0±0.01 Thickness, mm: 1.9±0.1 Refractive index, mm: 1.823 Optical aperture, mm2: 10.5*0.45 Back focal length, mm: 0.09 Transmission, %: >99.5 Pitch, mm: 0.4 Antireflection coating, nm at one of the wavelengths from the range: 400-1500 Numerical aperture: FA: 0.6, SA:0.09 Surface quality at λ = 633 nm: λ/4 Residual deviation at full angle FW1/e2 mrad: <7, <10, <13
INZHEKT
Saratov
Produced in: Saratov
XFP Transceiver
XFP Transceiver
XFP (10-Gigabit Small Form Factor Pluggable) is a protocol—independent hot-swappable optical transceiver, usually operating at 850nm, 1310nm or 1550nm wavelengths or wavelengths from the CWDM band at a speed of 10 gigabits per second in SONET/SDH, Fiber Channel, Gigabit Ethernet, 10 Gigabit Ethernet and other applications, including WDM channels.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Red Laser Module KLM-M635-4-5 635nm 4MW with Modulation
Red Laser Module KLM-M635-4-5 635nm 4MW with Modulation
from 3 596 ₽
Laser modules of the KLM-M635-4-5 series are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
A set of devices for studying the properties of electromagnetic waves
A set of devices for studying the properties of electromagnetic waves
The set of devices includes a microwave transmitter module, a microwave receiver module, a set of devices (metal reflecting screens, a refractive prism, an absorbing screen, etc.) to demonstrate the properties of electromagnetic waves (radiation, absorption, reflection, refraction, interference, diffraction). Technical specifications: The wavelength of the microwave transmitter is 3 – 4 cm; The average value of the energy flux density emitted by the microwave transmitter meets the requirements of the SanPiN 2.4/2.1.8.9-36-2002 (no more than 10 MW/ sq. m.). Receiver (transmitter) weight, not more than 0.3 kg Overall dimensions of the receiver (transmitter) 172x25x77 mm The microwave receiver module has a built-in interface for connecting to a personal computer and provides the ability to display the measured information on the PC screen. The kit includes an electronic media with software (CD-ROM) to demonstrate the operation of the equipment on the monitor screen of a personal computer.
MNIPI
Minsk
Produced in: Belarus, Minsk
Low-frequency signal generator G3-132
Low-frequency signal generator G3-132
Technical specifications: The waveform is sinusoidal, rectangular (TTL) Frequency range from 0.1 Hz to 10 MHz Frequency setting error ±0.02% Frequency instability ±0.01% in 15 min Signal amplitude ± 2.5 V at 50 ohm load ±5 V without load Limits of adjustment of the output signal level from 2 mV to 1.85 V (skz) at a load of 50 ohms from 4 mV to 3.75 V (scz) without load Signal level unevenness ± 5% at frequencies from 0.1 to 10 Hz relative to 1 kHz ± 2% at frequencies from 10 Hz to 1 MHz ±10% at frequencies from 1 to 10 MHz Harmonic coefficient ± 0.2% at frequencies from 10 to 100 Hz ±0.07% at frequencies from 100 Hz to 20 kHz ± 0.2% at frequencies from 20 to 120 kHz ±1% at frequencies from 120 kHz to 1 MHz ±4% at frequencies from 1 to 10 MHz Parameters of the rectangular (TTL) signal form log. "1" 3 2.4 V; log. "0" ≤ 0.4 V In the frequency range from 0.1 Hz to 2 MHz, the duration of the front, the cutoff is not more than 100 ns Operating temperature range from minus 10 °C to + 40 °C Power supply ~230 V, 50 Hz; 10 V×A Dimensions; weight 210×71×255 mm; 2 kg
MNIPI
Minsk
Produced in: Belarus, Minsk