Search

396 products
View:
  • Selected: 1
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • Applying
    Loading...
  • 142
    Names
    Loading...
  • 37
    Manufacturer
    Loading...
  • 25
    Made in
    Loading...
  • 37
    Additional
    Loading...
View:
396 products
Frequency meters Ch3-81, Ch3-81/1
Frequency meters Ch3-81, Ch3-81/1
Designed to measure the frequency or single and averaged period of sinusoidal and pulse signals, as well as to measure the pulse duration and frequency ratio, with a guaranteed measurement error of up to 10-7za year. Description: Ch3-81 (inputs A, B, C) – range 0.1 Hz–2.5 GHz Ch3-81/1 (inputs A, B) – range 0.1 Hz–200 MHz Frequency measurement, frequency ratios Measurement of the period, duration of 1 microsecond–10000 s Signal level 30 mV–10 V (eff.), pulse up to 30 V Thermostated quartz 5 MHz: ±10-7 (year) ±7.5X10-9(day) Frequency temperature departure: ±2.5X10-8 (+5...+40 °C) Number of averaged periods: 1-104 Timestamps 10-7-10-3 s RS-232 interface 8-bit SD indicator Dimensions, weight 80X220X300 mm, 3 kg Power supply: ~ 220V, 20V
MNIPI
Minsk
Produced in: Belarus, Minsk
High-voltage test unit UPU-22
High-voltage test unit UPU-22
Technical specifications: Output voltage (DC and AC), 0 - 2 kV; 0 - 5 kV Built-in AC power supply, 10 - 25 A The amplitude value of the DC voltage ripple relative to the set output voltage of 5 kV at idle is not more than ± 5% Error in setting the output voltage, ± 3% Protection tripping current, 101 -- 140 mA Load current of DC and AC output voltage, not less than 1 mA The limit of measuring the resistance of the integrity of the circuit connection, 0, 01 – 0.10 ohms
MNIPI
Minsk
Produced in: Belarus, Minsk
Dosimeter SUR-1TS
Dosimeter SUR-1TS
The possibility of a qualitative assessment of the current radiation situation - continuously and under any conditions. You can put the device in your pocket, purse, etc. and forget about it. If you get into the zone of radioactive exposure, the alarm will immediately remind you of yourself and let you know about the danger with light and sound signals; The presence of light and sound alarms about the emergency level of radiation hazard; Durable body is made of cast duralumin; Protected by the copyright certificate, the original power supply circuit, which provides low current consumption, allows you to keep the device constantly on and instantly determine whether it enters the zone of radioactive danger; The possibility to operate the device without replacing the battery for a year or more.
NPP "ELEKTRONNYE PRIBORY"
Naberezhnye Chelny
Produced in: Tatarstan, Naberezhnye Chelny
Installation for verification of individual beta radiation dosimeters UPB-ID
Installation for verification of individual beta radiation dosimeters UPB-ID
Installation for verification and calibration of individual beta radiation dosimeters. Properties The unit transmits units of absorbed dose (PD) and absorbed dose rate (MPD) of beta radiation in a tissue equivalent substance at a depth corresponding to a surface density of 7 mg•cm-2; the transition to units of the individual equivalent of the Hp dose (0.07) in sieverts from units of beta radiation absorbed in the tissue in gray is carried out using conversion coefficients recommended by the international standard ISO 6980-3:2006; the installation can be used in metrological bodies for verification of individual beta radiation dosimeters such as DMC 2000 XB, EPD Mk2 and others.
Doza
Zelenograd
Produced in: Moscow
Measuring antenna P6-23M
Measuring antenna P6-23M
Technical specifications: Frequency range (0.85 - 17.44 GHz) Standing Wave Coefficient (SWR) < 1.7 Effective area at least in the frequency range - from 0.85 to 15 GHz > 150 cm2 - from 15 to 17.44 GHz > 110 cm2 The margin of error of the effective area in the frequency range, no more - from 0.85 to 8.5 GHz ± 20% - from 8.5 to 17.44 GHz ± 15% Orthogonal polarization signal level -25 dB The level of the side lobes, no more than -10 dB Ambient temperature -50°C - 50°C Gabbar dimensions (HxWxD) 887x351x265 mm Weight 6,8 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
VD-7.2×3.4
VD-7.2×3.4
A flexible waveguide is a piece of high-quality dielectric, which ends with transitions to standard waveguides with flanges. For ease of operation, the waveguide is protected by an elastic shell. Basic properties Manufacturability of the connection; Small losses and VSWR; Economy. Operating conditions Operating temperature range from 5 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 7.2×3.4 Flange type according to GOST RV 51914-2002 Frequency range, GHz 25.95-37.50 VSWR 1.25 Losses, dB 2.0 Length, mm* 500
Produced in: Moscow
Spectrum Analyzer S4-101
Spectrum Analyzer S4-101
Technical specifications: The operating frequency range of the monitored signals is from 9·103 to 3·109 Hz The analyzer has a zero band and a viewing band in the range from 100 Hz to 3 GHz Limits of permissible error of setting the viewing band ± 1 % The scan range is set from 10 ms to 3000 s in all modes except the zero band of view, and from 20 microseconds to 3000 s in the zero band of view mode The bandwidth of the RFP at the level of minus 3 dB is selected in the range from 100 Hz to 1 MHz in increments of 1, 3, 10 The squareness coefficient of the FPC at the level of minus 60 dB / minus 3 dB is not more than 5:1 The reference level setting range is from plus 30 dBm to minus 100 dBm. Installation step 1 dB Limits of the permissible basic error of setting the reference level ± 1 dB The limits of the unevenness of the amplitude-frequency response (frequency response) of the analyzer in the frequency range from 100 kHz to 3 GHz ± 1 dB Maximum allowable input power is 30 dBm (1 W) Limits of the permissible basic error of measuring the signal level due to the nonlinearity of the logarithmic scale ± 1 dB Limits of the permissible basic error of measuring the signal level due to switching of the input attenuator ± 1 dB Limits of error in measuring the signal level due to switching filters, ± 0.2 dB relative to the 1 kHz filter The average level of intrinsic noise at the FPC bandwidth of 100 Hz, the video filter band of 10 Hz and the input attenuator of 0 dB: - in the range from 100 kHz to 20 MHz minus 75 dBm - in the range from 20 MHz to 1.5 GHz minus 110 dBm - in the range from 1.5 to 3 GHz minus 105 dBm The input impedance of the analyzer is 50 ohms The voltage standing wave coefficient (VSWR) of the input with an input attenuator greater than 10 dB, no more: - 1.5 in the frequency range from 10 MHz to 2.5 GHz - 1.8 in the frequency range from 2.5 GHz to 3 GHz Diagonal screen size 21.5 cm Screen resolution 800x480 USB interface Overall dimensions – 398x220x150 mm Weight not more than 6.5 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
High-sensitivity HICMOS digital Camera
High-sensitivity HICMOS digital Camera
The highly sensitive HICMOS digital camera manufactured by Abisens LLC is used to register weak light signals, including bioluminescence, in real time, with a photon counting function and visualization of the signal accumulation process in real time (you do not need to wait for the end of the exposure time to see the light signal accumulated by this moment). It is used as a component of high-tech laboratory equipment for scientific research, including installation in the fluorescence and bioluminescence imaging System in LumoTrace® biological samples manufactured by Abisens LLC.
Abisens
Sirius
Produced in: Krasnodar region
Continuous measurement of temperature in the industrial area
Continuous measurement of temperature in the industrial area
Appointment: the continuous measurement system allows for continuous measurement of the heating temperature of the industrial bucket, to improve the stability and reliability of measuring the temperature of liquid metal. Due to the fixed measurement position, the system eliminates errors due to the human factor. This method of measuring temperature was researched and invented on the theory of an absolutely black body. The principle of the temperature measurement system is the immersion of a temperature probe into molten steel to determine the temperature. The temperature probe made of an absolutely black body is designed in a special way to receive an infrared radiation signal corresponding to the temperature of molten steel. Scope of application: Intermediate bucket Measuring range: Warming up the promkovsh: from 800°C to 1400°C; Molten steel: from 1400°C to 1600°C Accuracy: Preheating of the promkovsh 7 ° C; Molten steel: 3 ° C Response time: Hot response time 75 sec; Cold response time 4 min Measuring probe length: 964mm, 1100mm Durability of measuring probes: 12 hours, 24 hours, 48 hours Number of thermal shocks: up to 5 times
Produced in: Lipetsk
Vibrometer VVM-311
Vibrometer VVM-311
A portable vibrometer with a digital indicator is designed to measure the main vibration parameters (vibration acceleration, vibration velocity, vibration displacement) of operating equipment, machines and other objects in laboratory and industrial conditions.
VIBROPRIBOR
Yaroslavl
Produced in: Yaroslavl
Vibration automatic monitoring and tracking equipment "Basis-001"
Vibration automatic monitoring and tracking equipment "Basis-001"
The equipment "Basis-001" is designed to measure vibration parameters, set and automatically maintain vibration parameters, control the vibration spectrum and determine resonant frequencies as part of vibration electrodynamic test units of the VEDS series (VEDS-100M; 200M; 400M; 1500M) and similar
VIBROPRIBOR
Yaroslavl
Produced in: Yaroslavl
Filter holder FD-1D
Filter holder FD-1D
The filter holder is designed to install an aerosol filter of the AFA type in it. It is used in sampling systems of gas-aerosol media at radiation-hazardous and other production facilities.
Doza
Zelenograd
Produced in: Moscow