Search

395 products
View:
  • Selected: 1
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • Applying
    Loading...
  • 142
    Names
    Loading...
  • 36
    Manufacturer
    Loading...
  • 23
    Made in
    Loading...
  • 36
    Additional
    Loading...
View:
395 products
VD-7.2×3.4
VD-7.2×3.4
A flexible waveguide is a piece of high-quality dielectric, which ends with transitions to standard waveguides with flanges. For ease of operation, the waveguide is protected by an elastic shell. Basic properties Manufacturability of the connection; Small losses and VSWR; Economy. Operating conditions Operating temperature range from 5 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 7.2×3.4 Flange type according to GOST RV 51914-2002 Frequency range, GHz 25.95-37.50 VSWR 1.25 Losses, dB 2.0 Length, mm* 500
Produced in: Moscow
Dosimeter SUR-1TS
Dosimeter SUR-1TS
The possibility of a qualitative assessment of the current radiation situation - continuously and under any conditions. You can put the device in your pocket, purse, etc. and forget about it. If you get into the zone of radioactive exposure, the alarm will immediately remind you of yourself and let you know about the danger with light and sound signals; The presence of light and sound alarms about the emergency level of radiation hazard; Durable body is made of cast duralumin; Protected by the copyright certificate, the original power supply circuit, which provides low current consumption, allows you to keep the device constantly on and instantly determine whether it enters the zone of radioactive danger; The possibility to operate the device without replacing the battery for a year or more.
NPP "ELEKTRONNYE PRIBORY"
Naberezhnye Chelny
Produced in: Tatarstan, Naberezhnye Chelny
Verification module PM-9
Verification module PM-9
The composition of the PM-9 calibration module: Universal voltmeter calibrator H4-12 (2 pcs.); Variable voltage calibrator H5-5A; A measure of the stress ratio H4-8; AC voltage voltmeter VK3-78A; Generator-calibrator of harmonic signals SK6-122; The meter-calibrator of the harmonic coefficient SK6-20A; AC power source B2-7 (2 pcs.); The measure of DC electrical resistance is multi-valued MS3070-2; The measure of DC electrical resistance is multi-valued MS3055; Decadal high-resistance resistance magazine M-109R; Single-digit electrical resistance measures MS3080 (0.001; 0.01; 0.1 ohms); Electrical resistance measures unambiguous MS3050M (1, 10, 100, 1000, 10000, 100000 Om); The measure of electrical resistance is unambiguous P4013; The measure of electrical resistance is unambiguous P4023; The measure of electrical resistance is unambiguous P4033; PC, printer; Basic load-bearing structures (BNC). Technical specifications Measuring ranges of electrical quantities: Constant electrical voltage DC from 1 MV to 1000 V AC alternating electric voltage in the frequency range of 10 Hz ... 1 MHz from 10 mV to 1000 V Alternating electric voltage high-frequency VRF in the frequency range of 10 Hz ... 2000 MHz from 10 mV to 100 V Harmonic coefficient in the frequency range of 10 Hz ... 200 kHz from 0.001 to 100 % Ranges of reproduction of electrical quantities: Constant electrical voltage DC from 1 nV to 1000 V AC alternating electric voltage in the frequency range of 10 Hz ... 1 MHz from 3 MV to 1000 V Alternating electric voltage high-frequency VRF in the frequency range of 1 MHz ... 2000 MHz from 3 MV to 3 V DC electric current from 1 µA to 20 A The power of alternating electric current in the frequency range from 0.1 Hz to 10 kHz from 1 µA to 20 A Electrical resistance from 0.001 ohms to 11 ohms Harmonic coefficient in the frequency range from 10 Hz to 200 kHz from 0.001 to 100 % Measurement errors of electrical quantities: Constant electrical voltage DC ± (0.0011 ... 4.0) % AC alternating electric voltage, in the frequency range 10 Hz ... 1 MHz ± (0.0055 ... 1.2) % Alternating electric voltage high-frequency VRF in the frequency range 1 MHz ... 2000 MHz ± (0.2 ... 6.0) % Harmonic coefficient in the frequency range from 10 Hz to 200 kHz ± (0.0008 ... 2.0) % Errors in the reproduction of electrical quantities: Constant electrical voltage DC ± (0.0011 ... 4.0) % AC alternating electric voltage in the frequency range 10 Hz ... 1 MHz ± (0.0055 ... 4.0) % Alternating electric voltage high-frequency VRF in the frequency range 1 MHz ... 2000 MHz ± (0.6 ... 10.0) % DC power ± (0.0033 ... 0.5) % The power of alternating electric current in the frequency range from 10 Hz to 10 kHz ± (0.055 ... 1.0) % Electrical resistance ± (0.001 ... 1.0) % Harmonic coefficient in the frequency range from 10 Hz to 200 kHz ± (0.006 ... 2.0) % General technical characteristics: The area occupied by the module is 6-12 m2 Weight, not more than 430 kg Power supply voltage from 198 to 242 V with a frequency of (50 ± 0.5) Hz Power consumption, no more than 2000 VA
Produced in: Moscow
EVRAZOXY For high oxidation
EVRAZOXY For high oxidation
Purpose: Measurement of oxygen activity in molten steel Scope of application: Oxygen converters, electric arc furnaces, induction furnaces, blast furnaces, casting buckets Measurement range: from 50 to 2000 ppm O2 - metal oxidation from 1000 to 1800 °C - metal temperature from 0.010 to 0.200% - carbon content Accuracy: 0 + 3°C at 1554°C; (from 5 to 10) mV (depending on the level of oxygen activity) Measurement time: 8 sec Tube Length: from 100 to 1500 mm (other lengths are available on request) Slag Cap: Steel, cardboard Type of NSH: B, S, R
Produced in: Lipetsk
IR Laser Module KLM-D980-x-5 980nm
IR Laser Module KLM-D980-x-5 980nm
from 4 314 ₽
Laser modules of the KLM-D980-x-5 series are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Copper Transceiver SFP 10/100/1000Base-T
Copper Transceiver SFP 10/100/1000Base-T
from 2 175 ₽
Receiving and transmitting modules for electrical communication lines in SFP metal cases with separate optical input/output for an RJ-45 type electrical connector to transmit the signal over two optical fibres.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Rubidium frequency and time standards H1-1011
Rubidium frequency and time standards H1-1011
The modular construction principle makes it easy to adapt the devices to the specific requirements of the consumer. The standards are available in four versions – H1-1011, H1-1011/1, H1-1011/2 and H1-1011/3, which differ in metrological characteristics and a set of installed devices (modules). The built-in diagnostic system allows you to quickly determine the operability and condition of the main devices of the standards. On the front panel of the devices H1-1011 and H1-1011/2 there is an LCD display and a control panel, with which you can quickly receive information about the current parameters of the devices included in the devices and adjust the frequency of the output signals. The H1-1011 and H1-1011/2 standards can receive chronometric information from GLONASS and GPS satellite radio navigation systems and use it to synchronize the local time scale and automatically adjust the actual frequency value of the built-in highly stable rubidium frequency standard. The composition of the standards H1-1011 and H1-1011/2 includes: rubidium frequency standard H1-1014; MPR-01 satellite radio navigation systems receiver module; amplifier module for highly stable sinusoidal signals (at the customer's choice): MUS-01 (3 independent outputs 10 MHz, connector type SR-50-73FV); MUS-02 (3 independent outputs of 5 MHz, connector type SR-50-73FV); MUS-03 (3 independent outputs of 1, 5 and 10 MHz, connector type SR-50-73FV); MUS-04 (6 independent outputs of 1, 5 and 10 MHz in any combination at the customer's choice, SMA connector type); MS synthesizer module with software (SMA connector type) instead of an amplifier module (at the customer's request). The scope of delivery (at the request of the customer) includes an antenna for the SRNS receiver as part of: antenna unit; mounting device; antenna cable (maximum length 60 m). The H1-1011/1 and H1-1011/3 standards include: the rubidium frequency standard H1-1013; two modules of amplifiers of highly stable sinusoidal signals (at the customer's choice): MUS-01 (3 independent outputs 10 MHz, connector type SR-50-73FV); MUS-02 (3 independent outputs of 5 MHz, connector type SR-50-73FV); MUS-03 (3 independent outputs of 1, 5 and 10 MHz, connector type SR-50-73FV); MUS-04 (6 independent outputs of 1, 5 and 10 MHz in any combination at the customer's choice, SMA connector type); MS synthesizer module with software (SMA connector type) instead of an amplifier module (at the customer's request).
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
Low-frequency signal generator G3-131A
Low-frequency signal generator G3-131A
Technical specifications: The waveform is sinusoidal, rectangular (TTL) Frequency range from 2 Hz to 2 MHz Frequency setting error ±0.05% Frequency instability ±0.02% in 15 min Signal amplitude ±5 V at 600 ohm load ±10 V without load Limits for adjusting the output signal level from 1 mV to 3.75 V (scr) at a load of 600 ohms from 2 mV to 7.5 V (scz) without load Signal level unevenness ± 2% at frequencies from 20 Hz to 200 kHz relative to 1 kHz ± 5% at frequencies from 200 kHz to 2 MHz Harmonic coefficient ± 0.3% at frequencies from 2 to 20 Hz ± 0.2% at frequencies from 20 Hz to 100 kHz ±1% at frequencies from 100 kHz to 2 MHz Parameters of the rectangular (TTL) signal form log. "1" 3 2.4 V; log. "0" ≤ 0.4 V the duration of the front, the cutoff is not more than 100 ns Operating temperature range from minus 10 °C to + 40 °C Power supply ~230 V, 50 Hz; 10 V×A Dimensions; weight 210×71×255 mm; 2
MNIPI
Minsk
Produced in: Belarus, Minsk
AK-1000 Acoustic calibrator
AK-1000 Acoustic calibrator
characteristics The AK-1000 is recommended for use with OCTAVE-101A, OCTAVE-101AM, OCTAVE-110A, OCTAVE-110A-ECO, OCTAVE-121, OCTAPHONE-110, OCTAVE-201, ECOPHYSICS-110A sound meters. The AK-1000 can be used for calibration of acoustic measuring paths with VMK-205, MK-265, MR-201, M-201, MK-233 microphones, and other ½-inch microphones. technical specifications Reproducible ultrasound, dB (rel. 20 µPa): 94 and 114 The limits of the permissible basic error of the reproducible ultrasound, dB: ± 0.25 Limits of the permissible additional error of the ultrasound caused by a change in ambient temperature in the operating temperature range, dB: ± 0.08 Frequency of the reproduced sound pressure, Hz: 1000 Limits of the permissible basic relative error of reproduction of the sound pressure frequency, %: ± 0.7 Limits of the permissible additional relative error of the sound pressure frequency caused by a change in ambient temperature in the operating temperature range, %: ± 0.07 Coefficient of nonlinear distortion, %, not more than: 2.5 Weight (with batteries), kg, no more than: 0.250 Overall dimensions (length×diameter), mm, no more: 158×35 Operating conditions: - ambient temperature, ° C: from minus 10 to 50 - relative humidity (at 40 ° C), %, not more than: 90 - atmospheric pressure, kPa: from 65 to 108
Produced in: Moscow
Continuous measurement of temperature in the industrial area
Continuous measurement of temperature in the industrial area
Appointment: the continuous measurement system allows for continuous measurement of the heating temperature of the industrial bucket, to improve the stability and reliability of measuring the temperature of liquid metal. Due to the fixed measurement position, the system eliminates errors due to the human factor. This method of measuring temperature was researched and invented on the theory of an absolutely black body. The principle of the temperature measurement system is the immersion of a temperature probe into molten steel to determine the temperature. The temperature probe made of an absolutely black body is designed in a special way to receive an infrared radiation signal corresponding to the temperature of molten steel. Scope of application: Intermediate bucket Measuring range: Warming up the promkovsh: from 800°C to 1400°C; Molten steel: from 1400°C to 1600°C Accuracy: Preheating of the promkovsh 7 ° C; Molten steel: 3 ° C Response time: Hot response time 75 sec; Cold response time 4 min Measuring probe length: 964mm, 1100mm Durability of measuring probes: 12 hours, 24 hours, 48 hours Number of thermal shocks: up to 5 times
Produced in: Lipetsk
NTEGRA NANO IR
NTEGRA NANO IR
NT-MDT Spectrum Instruments is an INTEGRA Nano IR–scattering scanning near‑field optical microscope (s-NSOM) designed for the infrared spectral range. The AFM probe is located in the focus of an optical system that directs the IR laser radiation to the sample and collects the optical response. The collected radiation is sent to the Michelson interferometer for optical analysis. The far-field component of the collected signal is suppressed by synchronous detection. The INTEGRA Nano IR system allows detecting the amplitude and phase of the near-field signal. The spatial resolution of the resulting reflection and absorption contrasts is approximately 10 nm and is determined only by the size of the tip of the probe.
Produced in: Moscow, Zelenograd
Blue DPSS Laser 465 nm KLM-465-x
Blue DPSS Laser 465 nm KLM-465-x
DPSS lasers of the KLM-465/x series are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes. Technical specifications Radiation output power: up to 15 W Radiation wavelength: 465 nm Output beam diameter: 1.5mm Divergence of the radiation beam: 1.3 mrad Instability of radiation power: 5% Type of modulation: TTL or analog Time to enter the mode: 15min Spectral line width: 0.1nm
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg