Search

73 products
View:
  • Selected: 1
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
  • Selected: 0
    Additional
    Loading...
All filters
  • Applying
    Loading...
  • 68
    Names
    Loading...
  • 18
    Manufacturer
    Loading...
  • 15
    Made in
  • 35
    Additional
    Loading...
View:
73 products
Apparatus for determining resins by evaporation by air jet TOS-LAB-02
Apparatus for determining resins by evaporation by air jet TOS-LAB-02
Technical specifications: The range of set unit temperatures, °C from +50 to +250 Accuracy of temperature maintenance, °C ± 1 Time to reach a temperature of 162 ° C, no more, min. 40 Air consumption, l/min 180±32 Voltage, 220 V Power, W 2000 Overall dimensions, mm 410x305x250 Weight, kg 20
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Sulfur and Metal Analyzer SPECTROSCAN MSW
Sulfur and Metal Analyzer SPECTROSCAN MSW
Technical Regulation TR CU 013/2011 "On requirements for automotive and aviation gasoline, diesel and marine fuel, jet fuel and fuel oil" imposes requirements for the content of sulfur and metals in automotive fuel. The analyzer allows you to measure, in order to confirm the conformity of the fuel, according to the following indicators: mass fraction of sulfur, concentration of iron, manganese and lead. The analyzer implements an arbitration method for measuring the mass fraction of sulfur in automotive fuel of the third, fourth and fifth classes according to GOST R 52660-2006 / GOST ISO 20884-2016, and also allows you to measure the mass fraction of iron, manganese and lead. The MSW SPECTROSCOPE is designed taking into account the requirements for measuring low sulfur and metal contents in petroleum products. Meets the requirements for equipment and precision standards: GOST R 52660-2006 / GOST ISO 20884-2016, GOST R 53203-2008, GOST 33194-2014, ASTM D6334. The design of the analyzer allows it to be used in mobile laboratories. The operator's actions when performing measurements are minimized: - the number/name of the sample is entered from the built-in keyboard; - the sample is poured into two cuvettes; - the obtained samples are placed in the analyzer and measurements are started. The analyzer performs all subsequent actions automatically without operator involvement: - calculates and displays the content of elements in the sample; - calculates convergence - the difference in determining the content of elements in the first and second samples; - prints measurement results on the built-in printer.
NPO Spektron
Saint Petersburg
Produced in: Saint Petersburg
The FLUORAT®-411 alarm is heated, with a built-in sample preparation system
The FLUORAT®-411 alarm is heated, with a built-in sample preparation system
1 supp.
Technical specifications: The power consumption of the alarm is not more than 150 watts The output electrical signal goes directly from the cable entry (B6), according to the standard scheme (4-20ma and (or) RS 485) Sample temperature is not more than 200 degrees C Sample pressure is not more than 1.5 Atm The pressure of the spent sample is not more than 0.5 Atm Cooling water temperature 5-30 Deg C Dimensions of the alarm (mm) 1200*600*400 The boundaries of the spectral range of optical radiation used for analysis, nm 240 - 380 Analysis time, from 1 Power supply - alternating voltage (220 ± 10%) V, (50± 2.5) Hz operating mode settings, min no more than 30 Display range , mg/l 0.01-30 The limit of the basic error for the trigger threshold (%) 20 The set threshold for triggering the alarm 0.1 – 30.9 in increments of 0.1 mg/l the probability of trouble-free operation during 5000 hours is not less than 0.95 average recovery time, no more than 2 hours average service life, at least 5 years
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Optical recorder of oil films "CRAB-1"
Optical recorder of oil films "CRAB-1"
1 supp.
Technical specifications: Sensitivity (minimum thickness of recorded oil films) from 0.5 microns The root-mean-square slope of the water surface up to 20 ° Distance from the receiving device up to 1000 m Sensor power supply 100-240 V, 50-60 Hz Power consumption up to 3 watts Ambient air temperature from -10 to +50 °C Humidity up to 100% (rain) Distance to the water surface 0.5–20 m Dimensions 120x180x120 mm Weight up to 1.5 kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Apparatus for dispersing petroleum products ARN-LAB-03
Apparatus for dispersing petroleum products ARN-LAB-03
A device for quality control of petroleum products Automatic apparatus for determining the maximum temperature of filterability on a cold filter with an integrated cooling system PTF-LAB-12 The automatic apparatus PTF-LAB-12 is designed to determine the maximum temperature of filterability on a cold filter in accordance with GOST 22254-92, GOST R 54269-2010, GOST EN 116-2013, ASTM D6371, IP309 and other similar standards in the temperature range from -67 ° C to room temperature. Developed taking into account all the requirements of state standards for testing. PTF-LAB-12 is equipped with an integrated cooling system of the bath, which allows you to reach the lower temperature limit of -67 ° C without using external cooling systems. Technical specifications: The volume of the analyzed sample is 45 ml Measurement range of filterability temperature from -67 °C to room temperature Accuracy of maintaining sample temperature ± 0.5 °C (at bath temperature -34 °C) ± 1.0 ° C (at bath temperature -51 °C) ± 2.0 °C (at bath temperature -67 °C) Creating a vacuum built-in diaphragm pump Maintaining the temperature of the cooling bath Integrated cooling system Step-by-step temperature control (-34 °C, -51 °C and -67 °C) Built-in memory of at least 1000 protocols Color LCD display with touch screen The device is controlled by touch Supply voltage 220 V Power consumption 300 W Overall dimensions, WxDxH 315x470x405 mm Weight 15 kg
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Automatic apparatus for analysis of turbidity/fluidity/solidification temperature of petroleum products TPZ-LAB-22
Automatic apparatus for analysis of turbidity/fluidity/solidification temperature of petroleum products TPZ-LAB-22
The parameters of accuracy, convergence and reproducibility are equivalent and correspond to the results obtained in accordance with the methods of ASTM D2500, ASTM D 97, GOST 20287 (methods A and B), GOST 5066 (for the determination of turbidity), GOST 5950, EN 23015, ISO 3015, ISO 3016, IP 15 TPZ-LAB-22 belongs to the latest generation of equipment of JSC "LOIP". The device is designed taking into account all the requirements of the standards for testing. A unique feature of TPZ-LAB-22 is a built–in cooling unit capable of cooling the test cell to -95 °C without the use of external cooling systems. The device automatically sets and maintains the temperature of the cooling bath, conducts tests, creates and stores test reports in memory. Technical specifications: The volume of the analyzed sample is 45 ml The operating temperature range of the test cell is -95...48°C Accuracy of temperature maintenance ± 0.5 °C Maintaining the temperature of the cooling bath Integrated cooling system Built-in memory of at least 1000 protocols Color LCD display with touch screen Supply voltage 220 V Power consumption 500 W Overall dimensions 300x560x550 mm Weight 25 kg
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Automatic apparatus for determining the flash point in an open crucible TVO-LAB-12
Automatic apparatus for determining the flash point in an open crucible TVO-LAB-12
Technical specifications: Flash temperature measurement range 0...400°C Heating speed 0.5...20°C/min The ignition period is 0.5...10°C Igniting a gas flame Flash/ignition ionization sensor Power consumption from AC 220V, no more than 700 watts Overall dimensions 405x340x265 mm The weight of the device is 12 kg
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Automatic Rapid Analysis device for turbidity/solidification temperature of petroleum products TPZ-LAB-12
Automatic Rapid Analysis device for turbidity/solidification temperature of petroleum products TPZ-LAB-12
TPZ-LAB-12 belongs to the latest generation of equipment of JSC "LOIP". The device is designed taking into account all the requirements of the standards for testing. A unique feature of TPZ-LAB-12 is a built–in cooling unit capable of cooling the test cell to -85 °C without the use of external cooling systems. The device automatically sets and maintains the temperature of the cooling bath, conducts tests to determine the temperature of turbidity and solidification, creates and stores test reports in memory. Technical specifications: The volume of the analyzed sample is 4.5 ml Temperature range of the test cell -85...+51°C Accuracy of temperature maintenance ± 0.5 °C Maintaining the temperature of the cooling bath Integrated cooling system Built-in memory of at least 1000 protocols Color LCD display with touch screen Supply voltage 220 V Power consumption 250 W Overall dimensions 315x470x405 mm Weight 15 kg
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Apparatus for determining the flash point in a closed crucible TVZ-LAB-01
Apparatus for determining the flash point in a closed crucible TVZ-LAB-01
The analyzer automatically heats the sample crucible and moves the test flame. The flash moment is set visually and recorded by pressing the "STOP" button, while the flash temperature is displayed on the display. Technical specifications: Flash temperature measurement range (with crucible cooling), °C from +40 to +400* The heating rate of the crucible with the sample, °C/min 0..20 Igniting a gas flame The speed of the stirrer, rpm 30...240 Power consumption from AC 220 V, no more, 600 W Overall dimensions of the device, not more than 350x250x280 mm Weight of the device, not more than, kg 8
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Apparatus for determining the flash point in an open crucible TVO-LAB-01
Apparatus for determining the flash point in an open crucible TVO-LAB-01
The analyzer automatically heats the sample crucible and moves the test flame. The flash moment is set visually and recorded by pressing the "STOP" button, while the flash temperature is displayed on the display. Technical specifications: Flash temperature measurement range, °C from +79 to +400 Heating speed, °C/min 2.0...20.0 Power consumption from AC 220 V, no more, 800 W Overall dimensions of the device, not more than, mm 400x360x470 Weight of the device, not more than, kg 14 Igniting a gas flame
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Low-temperature thermostat for determining viscosity LT-912
Low-temperature thermostat for determining viscosity LT-912
The LT-912 low-temperature thermostat (cryostat) is designed for thermostating glass viscometers when determining the kinematic viscosity of various samples, in particular, petroleum products according to GOST 33, ISO 3104, ASTM D 445, in the temperature range from -40 ° C to +100 °C. Technical specifications: Number of seats for viscometers 2 Operating temperature range, -40 °C ... +100 Accuracy of temperature maintenance, °C ± 0.01 Accuracy of the set setpoint temperature, °C ± 0.02 Working depth, mm 300 Volume of working fluid, l 9.5 Power consumption, W 2900 Overall dimensions (WxDxH), mm 470x480x650 Weight, kg 45
LOIP
Saint Petersburg
Produced in: Saint Petersburg