Search

477 products
View:
  • Selected: 1
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • Applying
    Loading...
  • 89
    Names
    Loading...
  • 34
    Manufacturer
    Loading...
  • 26
    Made in
    Loading...
  • 39
    Additional
    Loading...
View:
477 products
High-sensitivity HICMOS digital Camera
High-sensitivity HICMOS digital Camera
The highly sensitive HICMOS digital camera manufactured by Abisens LLC is used to register weak light signals, including bioluminescence, in real time, with a photon counting function and visualization of the signal accumulation process in real time (you do not need to wait for the end of the exposure time to see the light signal accumulated by this moment). It is used as a component of high-tech laboratory equipment for scientific research, including installation in the fluorescence and bioluminescence imaging System in LumoTrace® biological samples manufactured by Abisens LLC.
Abisens
Sirius
Produced in: Krasnodar region
RNA Vaccine production System
RNA Vaccine production System
1 supp.
It allows the generation of lipid particles for their subsequent use in the creation of RNA vaccines. The Russian equivalent of Nanoassembler systems.
Abisens
Sirius
Produced in: Krasnodar region
Optical imaging system for fluorescence and luminescence in LumoTrace® biological samples: LumoTrace® Lite model (bioluminescence)
Optical imaging system for fluorescence and luminescence in LumoTrace® biological samples: LumoTrace® Lite model (bioluminescence)
The lowest cost and most compact version of the LumoTrace® Optical Imaging System manufactured by Abisens LLC for sensitive bioluminescence detection. The compactness and low price of the LumoTrace®Lite imaging system are due to the fact that it allows only bioluminescence to be recorded (older models, in addition to bioluminescence, allow fluorescence to be recorded, and are also modular, which provides them with the opportunity to upgrade). Despite its compactness and relatively low price, this model is equipped with a new highly sensitive digital camera HICMOS manufactured by Abisens LLC, which allows recording ultra-small amounts of phosphor both in laboratory animals in vivo and in vitro experiments. The device is an indispensable tool for conducting preclinical studies on the way to the introduction of advanced drugs, in the implementation of non-invasive monitoring of the development of socially significant diseases, monitoring the effectiveness of immuno- and gene therapy,
Abisens
Sirius
Produced in: Krasnodar region
Magnetic stirrer without heating PL-R-basic, working volume 10 liters Primelab
Magnetic stirrer without heating PL-R-basic, working volume 10 liters Primelab
from 21 600 ₽
The mixer operates in a speed range from 50 to 1500 rpm, the maximum heating temperature of the working surface is 500 °C. The heating plate includes a base made of stainless steel and a working surface made of fire-resistant glass (glass ceramics). At temperatures above +550 °C, automatic overheating protection is triggered and turns off the heating. The device is equipped with an LCD screen to display set and actual temperatures, rotation speeds and additional animated icons. There is a timer for the specified operating time of the mixer; its maximum value is 990 minutes. There is a function for automatic detection of armature rotation failure. When the device detects an armature failure, the rotation stops. Then rotation resumes, but the speed is reduced by 10%, followed by restoration of the rotation speed to the user-specified parameters. A stall occurs if the armature becomes disengaged with the stirrer magnet and stops rotating. Disruption can occur for various reasons: the rotation speed is too high, the viscosity of the medium has changed during the mixing process, etc. When the power of the device is turned off, the set values of temperature, speed, timer time and the mode of detection (determination) of failure of armature rotation are stored in non-volatile memory. The armature rotation speed and heating temperature are set using two rotating knobs. Characteristics Motor power 16 W Range of operating speeds of the motor shaft, 200-1500 rpm Discreteness of setting the specified speed of rotation of the motor shaft, 10 rpm Resolution of displayed motor shaft rotation speed, 10 rpm Connection – external temperature sensor PT1000 (sold separately) Power consumption, 20 W Dimensions, weight Overall dimensions LxWxH, 380x220x120mm Working surface size, LxW, 200x200mm Maximum anchor length, 80mm Device weight 4.4 kg Contents of delivery Stirrer without heating PL-R-basic Operating manual combined with passport Anchor for stirrer in fluoroplastic sheath 8*50 mm Power cable with Euro plug
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Overhead mixer Primelab TM-50
Overhead mixer Primelab TM-50
from 35 000 ₽
Main features and benefits: - The compact and ergonomic design of the mixer body allows it to be used not only in stationary laboratories, but also in mobile mobile stations. - The submersible type device is ideal for a wide range of laboratory work. - Intuitive system for smooth power adjustment via the handle. - Start and stop the device using just one button located on the front panel, providing excellent ease of use. - The built-in temperature sensor automatically turns off the mixer if there is a risk of motor overheating, ensuring safety and reliability in operation. Structure and operation of the device: - The device is made in the form of a compact block made of a plastic case, which makes it light and convenient to use. - On the front panel of the device there is a potentiometer knob with a switch and an LED indicator. - On the back of the case there is a hole with a diameter of 7 mm for installing a bracket and a connector for connecting a power supply. - The lower part of the device is equipped with a three-jaw chuck on a hollow shaft. - The top of the device has a hole for the shaft of the mixing nozzle, which allows you to change the height of the nozzle without moving the device up or down if it is installed on a tripod. - The device also has the function of overload protection and complete shaft locking, which ensures its long service life and protects it from unpleasant situations. Primelab is an innovative and user-friendly overhead drive mixer developed in Russia. Thanks to its technological capabilities and ease of operation, it will become an indispensable tool for achieving high quality and efficient mixing of viscous and dense liquids in various fields of industry and scientific research. Characteristics Device overload protection Eat Max. viscosity of the stirred sample, mPa*s 10,000 Maximum torque, Ncm 45 A country Russia Control type analog Mixer shaft diameter max., mm 0.5-10 Motor type Brushless, DC Speed range, rpm 20-2200 Overall dimensions, L×W×H, mm 182x61x200 Protection class acc. to DIN EN60529 IP44 Sample volume (water) 20 liters Display absent Timer absent Engine power, W 53 Power consumption, W 24 Device weight, kg net/gross, kg 2.0/3.2 Supply voltage, V 200–240 Current frequency, Hz 50 Overheat protection (shutdown) Eat The device is supplied with: 1) device – 1 piece; 2) power supply – 1 pc.; 3) power cable – 1 pc.; 4) instruction manual combined with passport – 1 pc.; 5) bracket Ø10 mm. for attaching the device to a tripod – 1 PC.; 6) hex key 3 mm. - 1 PC.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Magnetic stirrer with heating for 2 liters PL-HR-atom
Magnetic stirrer with heating for 2 liters PL-HR-atom
from 19 000 ₽
1 supp.
The 2-liter heated magnetic stirrer PL-HR-atom is an indispensable device in any laboratory. The compact and powerful mixer allows high-quality mixing of small volumes of media that require additional heating. The device is easy to use: it is equipped with a knob-button for setting speed and temperature, which allows you to clearly set the desired characteristics; all values are clearly displayed on the display. Basic Range of operating speeds of the engine shaft, rpm 150-2000 Number of heating places - 1 Maximum volume of heated liquid, l - 2 The working surface of the stove is fire-resistant glass (glass ceramics) Size of the working surface of the plate, LxW, mm - 128 Maximum stove heating temperature, °C - +150 Protection class acc. to DIN EN60529 IP21 Characteristics Heating element power, W - 300 Discreteness of setting the set plate temperature, °C - 1 Accuracy of maintaining the plate temperature, % - 1 Resolution of displayed temperature, °C - 0.1 Connection – external temperature sensor PT1000 (sold separately) Power consumption, W - 300 Features of the model: 1. 7-segment display showing: - speed; - set and actual temperatures; - timer 99 min. Overall dimensions, LxWxH, mm 160x148x64 Device weight, kg 0.9
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Universal biochemical analyzer "FLUORAT®-02-ABLF-T"
Universal biochemical analyzer "FLUORAT®-02-ABLF-T"
1 supp.
Technical characteristics: Consumption of working reagents 1.0–2.0 ml – for standard filling cuvette K10 from 400 ml – for photometric techniques Filters for photometer mode, nm built-in interference filters 340, 405, 505 ,545, 575, 630 spectral half-width of 10 nm Filters for fluorimeter and chemiluminometer modes on request, in the spectral range of 270-850 nm Chemiluminescence channel sensitivity 10000 photons per second Optical density measurement range, E.O.P. 0-2.20 Photometric channel accuracy, %2 Memory of 100 measurement programs Temperature control of the measuring cell (for photometer and chemiluminometer modes) built-in thermostat on the Peltier element: 25, 30, 37 OC; accuracy ± 0.2 oC Volume of the flow cuvette, mkl 80 Pump type (only for photometer mode) peristaltic pump with programmable liquid supply volume Productivity, analyses/hour up to 100 (by the endpoint method) Information output liquid crystal display and personal computer Power supply, 220 ± 22 Dimensions, mm 430x350x160 Weight, kg 10
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Biochemical analyzer (photometer) "BIALAB-100"
Biochemical analyzer (photometer) "BIALAB-100"
1 supp.
Technical specifications: Methods of analysis optical density, endpoint, kinetics, fixed time, nonlinear, two-wave, turbidimetry Light source halogen lamp (12 V, 20 W) with a slow start system to increase the service life Built-in interference light filters 340, 405, 505, 546, 578, 630nm; spectral half-width 12 nm The optical density measurement range is 0-2.5 E.O.P. The measurement error of optical transmission is not more than 1 % Memory of 100 measurement programs Temperature control of the measuring cell built-in thermostat with Peltier element: 25, 30, 37 ° C; accuracy ± 0.2 ° C Sample incubation thermostat external, for 16 vials The volume of the flow cell is 32 µl Consumption of the working reagent from 250 µl Built-in matrix printer, printing on plain paper with a tape width of 56 mm Liquid crystal display: 4 lines of 20 characters each Productivity of up to 100 analyses/hour by the endpoint method Dimensions and weight no more than 355x355x185 mm; 8.5 kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Device for automatic isolation of nucleic acids COLIBRI
Device for automatic isolation of nucleic acids COLIBRI
from 2 840 000 ₽
1 supp.
The open system allows you to work with reagents and laboratory plastics from various manufacturers Russian-language software Modifications: - COLIBRI 24 - the ability to select from 1 to 24 samples - COLIBRI 48 - the ability to select from 1 to 48 samples - COLIBRI 96 - the ability to select from 1 to 96 samples Range of working volumes: - COLIBRI 24 - 200 – 5000 mkl - COLIBRI 48 - 30 – 1000 mkl - COLIBRI 96 - 20 – 1000 mkl A unique format of consumable plastic - 8-hole strips and combs Two built-in thermostats The accuracy of temperature maintenance is ± 1 °C Heating/cooling - up to 100 °C / up to 35 °C Universal Thermostat Tube Unit Built-in computer Ready-made allocation protocols The time of one extraction cycle is from 11 minutes Built-in bactericidal UV lamp for interior treatment
SYNTOL
Москва
Produced in: Moscow