GeneMack Strela Automatic Nucleic Acid Isolation Station
GeneMack Strela Automatic Nucleic Acid Isolation Station
1 supp.
The Strela automatic nucleic Acid isolation station is suitable for laboratories with a small sample flow seeking to optimize workflow and improve reproducibility of results. The station is being developed and assembled in Russia. Station Features: • Separation on magnetic particles – high yield of nucleic acids and excellent purity • The quality and concentration of the resulting DNA is sufficient for all molecular applications, including NGS • Ability to work with different types of samples, including complex samples (whole blood, FFPE, cfDNA, dry blood stains, saliva, hair, nails, etc.) • Simultaneous isolation of 1 to 13 samples • About 30 minutes per allocation, depending on the protocol • No overspending of plastic – load exactly as many cartridges as you are going to allocate samples • A large number of built-in protocols, the ability to program your protocols for different cartridges • User-friendly and intuitive interface • The station is compatible with cartridges from different manufacturers • 24/7 technical support in Russian Technical specifications Device Type: Desktop automatic device Minimum load: 1 sample Maximum load: 13 samples Reagent format: Bottled and sealed in individual cartridges Protocol execution time: From 16 to 60 minutes (depending on the allocation protocol program) Dosage volume: 25-1000 µl Dosing accuracy: No more than 5% CV Control: LCD Touch screen, 7 inches, 1025x600 Software language: Russian Heating unit with temperature control: from 30C to 80C (at room temperature+ 25C) UV lamp: Available Input voltage: 220V Overall dimensions (W x L x H): 54 x 57 x 61 cm Weight: 60 kg The installation location is only indoors Ambient operating temperature 15-40°C
Aivok
Zelenograd
Produced in: Moscow, Zelenograd
SPINNIX Centrifuge/Vortex, 2800 rpm, with a set of rotors
SPINNIX Centrifuge/Vortex, 2800 rpm, with a set of rotors
1 supp.
The Centrifuge/Vortex combines the functions of a vortex and a centrifuge in one device and is small in size, which saves space on the desktop or in the PCR box. Centrifuge characteristics:
  • Maximum rotation speed - 2800 rpm;
  • Maximum capacity - 12×1.5/2 ml (rotor R-1.5M);
  • vortex mode for one tube only;
  • timer - no;
  • covers - no;
  • operating mode - continuous and pulsed;
  • available rotors, pcs. - 3;
  • dimensions, W×D×H, mm – 120×170×120;
  • weight, kg - 1.4.
Aivok
Zelenograd
Produced in: Zelenograd
PCR tablet for 96 wells 0.2 ml stripped
PCR tablet for 96 wells 0.2 ml stripped
from 160 ₽
The 96-hole tablet of the standard profile is made of ultrapure polypropylene for PCR. The wells have thin walls (0.3-0.35 mm.), providing rapid heat exchange, allowing optimal amplification results to be achieved. The wells are easily separated from each other in any direction into any number of tubes (up to a single one). Compatible with SFG adapters for PCR amplifiers. Tablets are convenient both for high-performance laboratories and for single analyses. The presence of a skirt — Without a skirt Material — Ultrapure Polypropylene The wall thickness is 0.3 — 0.35 mm. Color — White Sterility — Heat treatment in an autoclave at 121 °C for 15 minutes. Marking — Alphanumeric with engraving Profile: Standard
VIS MED
Berdsk
Produced in: Berdsk, Novosibirsk region
LB-1K laminar flow microbiological Safety box
LB-1K laminar flow microbiological Safety box
1 supp.
• OKP code 94 4370 • The color of the box is resistant to treatment with desolutions. • Number of filtration degrees: 1 or 2 • Pre-filter class according to GOST R 51251-99: G4 • HEPA filter class according to GOST R 51251-99: N14 • Efficiency of air purification from suspended particles larger than 0.2 microns (MPPS) according to GOST R 51251-99 (EN1812) for a filter of class H14: 99.995% • Air purity class of the working area according to GOST R ISO 14644-1-2002 (in particles of 0.5 microns): 5ISO • Protection class (according to WHO classification): IIA • Total air capacity: 1350 m3/hour • Capacity for air entering the working chamber of the box: adjustable, from 400 to 900 m3/hour • Recycling rate: 80% • The air flow rate in the working area is adjustable: from 0.2 to 0.45 m/s • The internal chamber of high pressure is surrounded on all sides by zones of low pressure relative to atmospheric pressure • UV lamp power of the working chamber: 30 W • Sound power level of the laminar flow box: no more than 57 dBA • Illumination of the working area of the laminar flow box: at least 1000 Lux • Shadowless lighting of the working area of the laminar flow box: combined • Flat removable sectional table top made of AISI304 stainless steel • The front glass is made of polycarbonate resistant to UV radiation • Suspended front window with lifting and stopping at any level • Nameplate panel with a w/c screen indicating the activation of the product systems, a timer for the operation of the UFO working chamber, a counter for the operation of the UFO, a clock, a technological timer, an automatic air flow maintenance system • The control panel is located outside the work area, which provides easy access during repairs and no contact with potentially dangerous agents in the duct and air purification system • Sockets in the work area: 2 pcs. One outlet is controlled by the time set from the controller keyboard • Power consumption: 210W • Weight of the box: no more than 120 kg • Dimensions of the working chamber of the laminar flow box (WxDxH): 1160x570x630 mm • External dimensions of the laminar flow box (WxDxH): 1200x670x1270 mm • Dimensions of the stand (WxDxH): 1200x670x650 mm • Warranty period: 18 months from the date of delivery and acceptance of the product • Package dimensions (WxDxH): 1290x780x1370 mm
Prointekh
Pushchino
Produced in: Moscow region, Pushchino