Search

480 products
View:
  • Selected: 1
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • Applying
    Loading...
  • 90
    Names
    Loading...
  • 33
    Manufacturer
    Loading...
  • 26
    Made in
    Loading...
  • 35
    Additional
    Loading...
View:
480 products
Vacuum tube MiniMed with K2-EDTA, 4 ml, 13×75mm, purple, PET, pack.100 pcs
Vacuum tube MiniMed with K2-EDTA, 4 ml, 13×75mm, purple, PET, pack.100 pcs
from 690 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Material for research............... stabilized EDTA whole blood /EDTA plasma. Scope of application............................ hematological examination of whole blood
MiniMed
Suponevo
Produced in: Bryansk region
Red Laser Module KLM-M650-40-5 650nm 40mw with Modulation
Red Laser Module KLM-M650-40-5 650nm 40mw with Modulation
from 17 259 ₽
KLM-M650-40-5 laser modules are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Vacuum tube MiniMed with coagulation activator, 10ml, 16×100mm, orange, PET, pack.100 pcs.
Vacuum tube MiniMed with coagulation activator, 10ml, 16×100mm, orange, PET, pack.100 pcs.
from 1 021 ₽
The walls of the tubes are coated with a dry clot formation activator (silicon dioxide) to accelerate blood clotting. Mixing blood with it does not affect the result of tests. The acceleration of the blood clotting process significantly reduces the preparation time of the biological sample. Material for research............... blood serum Scope of application............................ blood serum research in biochemistry, immunology Centrifugation................................ 1000 - 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with K3-EDTA and separation gel, 3 ml, 13×75mm, purple, PET, pack.100 pcs,
Vacuum tube MiniMed with K3-EDTA and separation gel, 3 ml, 13×75mm, purple, PET, pack.100 pcs,
from 858 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Gel is a special material designed to form a stable barrier between the cellular components of blood and serum during centrifugation. Material for research............... EDTA-blood, plasma Scope of application............................ hematological examination of whole blood
MiniMed
Suponevo
Produced in: Bryansk region
Genetic analyzer NANOPHORE 05 (DNA sequencer)
Genetic analyzer NANOPHORE 05 (DNA sequencer)
from 10 684 200 ₽
1 supp.
DNA sequencing and fragment analysis technologies are the most informative methods of DNA analysis, therefore NANOPHOR 05 devices are used to solve a wide range of tasks in personalized medicine and sanitary and epidemiological control, in criminology, animal husbandry, crop production, veterinary medicine, fisheries, quarantine and metrological services, as well as in basic scientific research. The genetic analyzer was developed and mass-produced in Russia by the consortium "Russian Genetic Technologies" as part of the Institute of Analytical Instrumentation of the Russian Academy of Sciences (St. Petersburg), the FGUP EZAN plant (Chernogolovka) and NPF Syntol LLC (Moscow). NANOPHORE 05 has registration certificate No. RNZ 2015/3474 dated March 11, 2022. Warranty service of the device: 24 months from the date of commissioning. Free training for the user on working with the device, commissioning, joint productions, as well as training in working with software. Technical and user characteristics Number of capillaries: 8 Tablet size: 96 x 0.2 ml Number of fluorescence detection channels: 7 Laser: solid-state Laser power: 110 MW Laser wavelength: 488 nm Voltage range: 0.1 - 15 kV Temperature maintenance range and accuracy: 30 - 70 °C (+/- 0.03 °C) Reading length with an accuracy of at least 99%: up to 950 nucleotides Standard fragment analysis time of up to 460 nucleotides: 34 minutes The maximum analyzed length of a DNA fragment (fragment analysis): at least 1200 nucleotides Weight: not more than 50 kg Applications: DNA sequencing by Sanger DNA fragment analysis (STR, QF-PCR, MSI, OLA, MLPA, SNaPshot, ISSR, AFLP, tRFLP) Identification of the person The genetic analyzer NANOPHORE 05 is distinguished by: - Wide dynamic range: the device demonstrates high sensitivity with a small amount of incoming material and high overload resistance with a large amount of incoming DNA. - Wide installation base: currently there are more than 250 devices installed in the most advanced laboratories in Russia, near and far abroad. Several million studies are performed annually on NANOPHORE 05 devices. - The low weight and reliability of the NANOPHORE 05 assembly make it possible to use the device for field work as part of mobile laboratories. - Prompt service and methodological support: directly from the manufacturer at all stages of interaction with the customer. A quick solution to any technical issue due to the fact that specialists from the chief designer to the assembly shop employee are located in Russia. - Regular schools on modern methods of DNA sequencing and fragment analysis. - High quality and availability of reagents: Our own production of reagents enables our customers to receive all the solutions necessary for their work from one source. Stable delivery times of NANOPHOR 05 devices, related equipment, reagents and consumables and long shelf life of reagents due to the production base in Russia. - Openness of the system: the ability to use reagents and kits from third-party manufacturers, the ability to create your own protocols.
SYNTOL
Москва
Produced in: Moscow
Vacuum tube MiniMed with separating gel, 5 ml, 13×100 mm, red, PET, pack.100 pcs,
Vacuum tube MiniMed with separating gel, 5 ml, 13×100 mm, red, PET, pack.100 pcs,
from 1 571 ₽
Tubes without fillers are used for the study of blood serum in biochemical, immunological and serological tests. The gel forms a stable barrier between the serum and the shaped elements during centrifugation. Research material............... blood serum Scope of application............................ blood serum research in biochemistry, immunology, serology Centrifugation................................ 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with separation gel, 10 ml, 16×100 mm, red, PET, pack.100 pcs.
Vacuum tube MiniMed with separation gel, 10 ml, 16×100 mm, red, PET, pack.100 pcs.
from 984 ₽
Tubes without fillers are used for the study of blood serum in biochemical, immunological and serological tests. The gel forms a stable barrier between the serum and the shaped elements during centrifugation. Research material............... blood serum Scope of application............................ blood serum research in biochemistry, immunology, serology Centrifugation................................ 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with K2-EDTA and separation gel, 4 ml, 13×100mm, purple, glass, pack.100 pcs,
Vacuum tube MiniMed with K2-EDTA and separation gel, 4 ml, 13×100mm, purple, glass, pack.100 pcs,
from 1 339 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Gel is a special material designed to form a stable barrier between the cellular components of blood and serum during centrifugation. Material for research............... EDTA-blood, plasma Scope of application............................ hematological examination of whole blood
MiniMed
Suponevo
Produced in: Bryansk region
MiniMed sterile tampon probe with a test tube with a Carey-Blair transport medium,TU 32.50.50-031-29508133-2019 , ind. pack./100 pcs./1000
MiniMed sterile tampon probe with a test tube with a Carey-Blair transport medium,TU 32.50.50-031-29508133-2019 , ind. pack./100 pcs./1000
from 2 100 ₽
Keri Blair transport medium is a modification of Stewart's basic transport medium designed specifically for the transportation and storage of fecal and rectal samples containing Salmonella spp., Shigella spp., Vibrio spp., Campylobacter spp., Pseudomonas spp., Escherichia coli and other microorganisms. This medium is standard for the transportation of anaerobes. Bacterial cultures are guaranteed to remain viable for up to 48 hours at a temperature of 15-22 ° C. The tampon probe is packed in a high-impact PP tube (12*150 mm). The test tube is provided with a label indicating: batch number, date of sterilization, expiration date, manufacturer, supplier, registration certificate, and also provides a place for applying information about the patient and the sample. The edge of the label is fastened with a stopper that closes the tube with a tampon - the label serves as the control of the first opening. Store at a temperature not lower than + 5 °C and not higher than + 25 °C.
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with K2-EDTA and separation gel, 9 ml, 16×100mm, purple, PET, pack.100 pcs.
Vacuum tube MiniMed with K2-EDTA and separation gel, 9 ml, 16×100mm, purple, PET, pack.100 pcs.
from 1 710 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Gel is a special material designed to form a stable barrier between the cellular components of blood and serum during centrifugation. Material for research............... EDTA-blood, plasma Scope of application............................ hematological examination of whole blood
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with coagulation activator and separation gel, 5ml,13*100 mm, yellow-orange, PET,pack.100,
Vacuum tube MiniMed with coagulation activator and separation gel, 5ml,13*100 mm, yellow-orange, PET,pack.100,
from 1 210 ₽
Test tubes are used for blood sampling in biochemistry and immunology. During centrifugation, the gel forms a strong barrier for 48 hours between the clot and the serum. The gel tubes must be centrifuged no later than 2 hours after blood collection. Material for research............... blood serum Scope of application............................ serum research in biochemistry, immunology Centrifugation.............................. 1500-2000 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region