Viscometer ZM-1001M-01
Viscometer ZM-1001M-01
The viscometer works under the control of a PC (Laptop). In the dialog mode, the operator sets the parameters necessary for testing liquids. The test results are displayed on a PC display, stored in a database and can be printed on a printer. Technical specifications The range of viscosity determination is from 0 to 1000 MPa ×s. The limits of the permissible relative error in determining the viscosity under normal conditions are 1%. The rotational speed of the measuring nozzle is from 0.1 to 900 rpm. The range of temperature control and determination of the temperature of the tested solutions under normal conditions is from 10 to 50 ° C. The limit of permissible absolute error of temperature control and temperature determination ± 2 °C. Normal operating conditions under which metrological and reliability parameters are normalized: type of current – alternating single-phase; supply voltage – (220 ± 22) V; ambient temperature – from +15 to +25 ° C; AC frequency – (50± 1) Hz; power consumption – no more than 240 VA. Operating conditions under which the additional error in determining the viscosity increases by ½ of the main one: ambient temperature – from +10 to +35 ° C; The electrical insulation resistance between the electrical circuits and the housing at ambient temperature (20 ± 5) ° C and relative humidity (80 ± 3)% is not less than 20 mOhm. The electrical insulation between the electrical circuits and the housing under the conditions of clause 2.8 must withstand an alternating current voltage of 1.5 kV of a sinusoidal shape with a frequency of 50 Hz. Overall dimensions of the viscometer, no more than 160x300x340mm. The average service life is at least 10 years. The mass of the viscometer is no more than 12 kg.
Produced in: Krasnodar
The verification complex ZM3003
The verification complex ZM3003
It has: a wide range of calibrated currents and voltages reproduction; wide frequency range at alternating current 20Hz – 20kHz; adjustment of the phase shift angle between current and voltage in the range 0 – 360 °; high accuracy of reproduction of current, voltage, phase shift angle. Normal operating conditions: ambient temperature (23 ± 5) ° C; the relative humidity of the surrounding air is 30-80 %; atmospheric pressure 84 — 106 kPa (630-795 mmHg); supply network voltage (220 ± 4.4) V; supply network frequency 48 — 62 Hz. Operating conditions: ambient temperature from 5 to 40 ° C; relative humidity up to 80 % at temperatures up to 30 ° C; atmospheric pressure 84 — 106 kPa (630 — 795 mmHg) supply voltage (220 ± 22) At a frequency of 48 — 62 Hz; The additional error in reproducing the voltage and strength of direct and alternating current, as well as the power from a change in the mains voltage by ± 10% of the nominal value of 220 V does not exceed half of the corresponding basic error. The additional error from the change in ambient temperature for every 10 ° C does not exceed half of the basic error. The electrical insulation resistance between the power supply circuits of the device and the housing is not less than: under normal conditions of use – 20 Mohm; at elevated ambient temperature — 5 Mom. The device can be used as part of automated measuring systems for various purposes with serial interfaces: RS-232C (EIA-2320) or USB. Overall dimensions: control unit 270 x448.8x496 mm, power unit 270 x448.8x496 mm. Weight: control unit 25 kg, amplifier unit 25 kg.
Produced in: Krasnodar
Areometer ADB-1M
Areometer ADB-1M
Device parameters: density measurement range, g/cm3 — with calibrated load — ( 0.8 to 1.7 ) — without calibrated load — ( 1.7 to 2.6 ) the price of dividing the hydrometer scale (main and correction), g/cm3— ( 0.01 ) working medium — water density from 0.96 to 1.039 g/cm3 at temperature, 0C — (from 5 to 50 ) the capacity of the hydrometer cup, cm3 — (78.5 +0.3) the limit of permissible absolute error at the temperature of the test solution, the environment and water 20 +2, g /cm3— (0.01) the mass of the calibrated load, g — (81.58 +0.1 ) overall dimensions of the hydrometer, mm — ( 66x454 ) weight of hydrometer with case, kg — ( 1,450 )
Produced in: Krasnodar
IMK-30 Torsion testing machine
IMK-30 Torsion testing machine
Technical specifications: Maximum load (torque): 30 N·m Maximum twisting angle: 50000° The discreteness of the twisting angle: 0.01° Twisting angle error: ±0.1° Torque discreteness: 0.001 N·m Relative error of torque measurement: no more than 1% in the measurement range from 0.6 to 30 Nm Torque measurement error: no more than 0.01 N·m in the measurement range from 0 to 0.6 N · m Maximum rotation speed: 10 rpm Weight: 150 kg Overall dimensions (length x width x height): 1000 x 500 x 500 mm Diameter of the universal testing device: 80 mm Maximum spring length: 300 mm or more
Produced in: Ivanovo