Search

372 products
View:
  • Selected: 1
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • Areas of use
    Loading...
  • 146
    Item names
    Loading...
  • 35
    Manufacturer
    Loading...
  • 24
    Made in
    Loading...
  • 34
    Additional
    Loading...
View:
372 products
Central Heating Unit N (CHU-N) Kit
Central Heating Unit N (CHU-N) Kit
It is designed to control the excess pressure during the crimping of pipelines before putting them into operation, as well as during scheduled system health checks. The devices are registered in the State Register of Measuring Instruments for No. 30414-11, No. 43646-10 and are approved for use in the Russian Federation. Features of the CHU-N kit Carrying out pressure testing before the start of commissioning allows you to identify possible defects in seams and pipes, ensuring their tightness and reliability of insulation. The kit is designed to work in the field in order to record and archive the measured results to identify possible defects. The CHU-M kit is a portable complex with autonomous power supply.
Produced in: Kolomna, Moscow region
Filter holder FD-05D
Filter holder FD-05D
The filter holder FD-05D is designed to install aerosol and iodine filters in it, in an amount of up to 8 pieces. The filters are arranged sequentially. It is used in sampling systems of gas-aerosol media at radiation-hazardous and other production facilities.
Doza
Zelenograd
Produced in: Moscow
Installation for measuring the parameters of the air flow multichannel USPVM
Installation for measuring the parameters of the air flow multichannel USPVM
The installation is intended for use in gas-aerosol emission control systems in order to determine the volumetric air flow in ventilation systems by measuring the linear air flow velocity at local points of the dimensional section, as well as for measuring air temperature and humidity at local points. The measuring system of the installation complies with GOST 12.3.018-79 (SSBT. Ventilation systems. Methods of aerodynamic tests).
Doza
Zelenograd
Produced in: Moscow
Oilman's Kit
Oilman's Kit
from 58 491 ₽
It measures temperature when checking the quality of fuel in samplers. •
Produced in: Moscow
Individual gamma and neutron radiation dosimeter DVS-02D
Individual gamma and neutron radiation dosimeter DVS-02D
Purpose: measurement of individual dose equivalent (IED) of mixed gamma-neutron radiation; measurement of individual dose equivalent (IED) of neutron radiation;
Doza
Zelenograd
Produced in: Moscow
Non-pressure hybrid flow meter-counter Volga Triton
Non-pressure hybrid flow meter-counter Volga Triton
from 300 000 ₽
The Volga Triton pressure-free hybrid flow meter is designed to measure the volumetric flow of liquid in water ducts with a pressure-free and combined pressure-free flow mode. The submerged primary speed converter operates on the basis of the Doppler effect, emitting an ultrasonic signal towards the flow and receiving an echo reflected from particles in the flow with a frequency different from the frequency of the emitted signal. This frequency shift is called the "Doppler Shift" and it is proportional to the flow rate. A non-contact ultrasonic primary converter VBN-DG-01 or any other third-party liquid level converter with a unified current output of 4-20 mA can be used as a depth meter: radar, hydrostatic or ultrasonic. The volumetric flow rate is determined both by the "area-speed" method and by MI2220-2013, depending on hydraulic conditions. In non-contact (radar) mode, the Volga Triton flowmeter is designed to measure the volumetric flow rate of a liquid in a non-pressurized flow mode. The flow meter can be used as part of waste water metering units in non-pressure (gravity) sewage systems, open irrigation and reclamation channels, open or underground derivational non-pressure water pipelines of hydropower facilities, diverting supply and recirculation water pipelines of thermal power and other hydraulic structures with a non-pressure flow regime. The measurement technology is based on a non-contact radar method for measuring surface flow velocity and a non-contact ultrasonic/radar method for measuring water level. As a water level meter, both the proprietary ultrasonic level sensor BP-G-01 and third-party sensors connected via unified digital or analog interfaces, for example, VEGAPLUS, can be used. The pressure-free hybrid flow meter "Volga Triton" became the winner of the International Environmental Award EWA Award 2021 in the nomination Best technology. Secondary converter It is available in both stationary (~220 V) and portable versions with autonomous power supply. Primary converters VBN-DS-01 Primary speed converter for medium and large water pipelines VBN-DS-02 Combined primary speed and depth converter for medium and small aqueducts VBN-DS-03 is a combined low-profile primary speed and depth converter for small aqueducts. VBN-DG-01 - contactless ultrasonic primary transducer - depth meter Pipe sizes Du, mm: 350, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, up to 6000 mm
Produced in: Moscow
Surface smart probe L=150 mm SZPV.150
Surface smart probe L=150 mm SZPV.150
from 10 920 ₽
The surfaCE SMART probe L=150 mm SZPV.150 is designed to measure the temperature of various materials by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor based on the Android program. Operating conditions of the SZPV.150 smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the SZPV.150 smart probe Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor based on the Android program. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor based on the Android program. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
Submersible smart probe L=150 mm SZPG.150
Submersible smart probe L=150 mm SZPG.150
from 10 626 ₽
The submersible smart probe L=150 mm SZPG.150 is designed to measure the temperature of various materials by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor, Android program installed. Operating conditions of the SZPG.150 smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the SZPG.150 smart probe Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
Power injector IP-2
Power injector IP-2
Purpose: provision of connected equipment with constant voltage; conversion of the RS-485 interface to USB (version 01 only) data transmission via the RS-485 interface (version 02 only).
Doza
Zelenograd
Produced in: Moscow
Smart probe of relative humidity and temperature L=500 mm SSVL.500P with built-in flash memory
Smart probe of relative humidity and temperature L=500 mm SSVL.500P with built-in flash memory
from 14 400 ₽
The smart probe of relative humidity and temperature L=500 mm with a built-in flash memory is designed to measure the temperature of gaseous materials without mechanical impurities and aggressive vapors, relative humidity by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the installed ThermoMonitor based on the Android program. Operating conditions of the SZVL.500P smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the smart probe SSVL.500P Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitorbased on the Android program. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor based on the Android program. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region