Search

2115 products
View:
  • Selected: 1
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • Applying
    Loading...
  • 284
    Names
    Loading...
  • 53
    Manufacturer
    Loading...
  • 38
    Made in
    Loading...
  • 61
    Additional
    Loading...
View:
2115 products
LAB table for microscopes-1500 CM
LAB table for microscopes-1500 CM
Furniture for laboratory work. Microscopy table Length, mm: 1500 Depth, mm: 700 Height, mm: 760(1140) TABLE top – laminate shelf for Petri dishes (8 cells with an internal size of 140*100*90mm, 3 cells with an internal size of 190*100*90mm) – melamine 16mm thick side decorative panels – melamine 16mm thick
LOIP
Saint Petersburg
Produced in: Saint Petersburg
UNM-1000 portable magnetizing device, power unit
UNM-1000 portable magnetizing device, power unit
from 552 000 ₽
The UNM-1000 allows to detect internal, subsurface and surface defects of different types (cracks, flokens, delaminations, defects of welding seams, etc.) in parts, structural elements, units and mechanisms of industrial units, railway, auto, air vehicles, as well as petrochemical, gas and technological equipment during the manufacturing and repair stages or during routine inspections of the products being in operation. The principle of operation of the UNM-1000 AC flaw detector The magnetic powder method of detecting defects in products made of ferromagnetic materials is based on the ability of magnetic powder particles to settle in the defect zone, where inhomogeneities of the magnetic field created by the magnetizing device arise. Unlike devices based on permanent magnets, magnetic particle flaw detectors allow you to set the current and time of magnetization and automatically demagnetize controlled samples. The UNM-1000 AC flaw detectors allow monitoring of products by the applied field method using various magnetization techniques. To do this, the alternating electric current generated by the flaw detector can be passed through a magnetizing cable or directly through a controlled product connected to the flaw detector using electrical contacts. The value of the current used for magnetization and demagnetization of the product is set by the operator of the device. Design features and advantages The UNM-1000 flaw detector is a portable device, which allows you to control the quality of products made of ferromagnetic materials both in production and in laboratory conditions. The basic set of equipment for magnetic particle flaw detection includes a UNM-1000 magnetizing device, a power cable for power supply from a single-phase AC network with a voltage of 220 V, and technical documentation. At the request of the customer, electrical contacts and a magnetizing AC cable can be additionally supplied. The advantages of the UNM-1000 device of the MANUL series include: the possibility of monitoring both in the applied magnetic field with longitudinal magnetization using power cables, and with circular magnetization by passing current through the controlled product; wide range of magnetization current adjustment from 50 to 1000 A; automatic demagnetization of controlled products; high performance; the device is compact and has light weight; the degree of protection from external influences is at least IP40. Scope of application of magnetic particle control means Due to its versatility, simplicity and ease of operation, the UNM-1000 magnetic particle flaw detector can be used in almost all non-destructive testing laboratories of workshops and assembly shops of the automotive and aviation industries, railway transport, for the needs of civil and military shipbuilding. Also, the UNM-1000 magnetic powder control device can be successfully used in the energy sector, in the production of pipelines, metal structures, construction equipment and related industries. Technical characteristics of the portable magnetizing device UNM-1000 fully complies with the requirements of the following standards: GOST R 56512-2015, GOST R 53700-2009 (ISO 9934-3:2002), GOST R 50.05.06-2018, GOST R ISO 10893-5-2016, GOST ISO 17638-2018, RD 34.17.102-88, RD-13-05-2006 , as well as other national and foreign regulations documents on standardization of magnetizing devices and flaw detectors for magnetic powder control. Technical specifications • Magnetization current: up to 1000A (RMS), 4.3V,50 Hz • Demagnetization mode • Weight: no more than 20kg • Overall dimensions (W×H×D): 290×160×450 mm • The device is powered by 220V, 50 Hz
Produced in: Moscow
Liquid thermostat THERMOTEST-05-1
Liquid thermostat THERMOTEST-05-1
Operating temperature range -80...+30 °C. Stability and uniformity of temperature in the working bath is not worse than ± 0.02 °C Bath volume 15 l Overall dimensions 510x800x1230 mm The open part of the bath is 90 mm Bath depth 430 mm Weight 115 kg Power consumption 4.2 kW
Produced in: Tomsk
ND-250 High-vacuum diffusion pump
ND-250 High-vacuum diffusion pump
The working condition of the ND-250(P) diffusion pump depends on the temperature of the working fluid in the pump boiler. During the initial filling, it is recommended to fill the maximum volume of the working fluid. Working fluid is "VACMA OIL 500" vacuum oil (under technical specifications TU 19.20.29-061-00218526-2019). The total amount of working fluid in the ND-250(R) diffusion pump is a maximum of 1.8 liters, a minimum of 1.3 liters. The viewing window for visual inspection of the working fluid has labels of its maximum and minimum amounts. During normal operation of the pump, the level of the working fluid almost does not change. The temperature of the working fluid when the pump is operating at the maximum residual pressure is about 240°C to 255°C. It is recommended to monitor the operation of heaters in the ND-250(R) diffusion pump using the same temperature sensor. The temperature sensor must be installed in a special radiator socket above the heater. If there is a loss of working fluid and an increase in the temperature of the radiators of the pump up to 320˚C, the temperature sensor must give the command to automatically turn off the heaters. The subsequent activation of the pump heaters should not be automatic and should be performed only after cooling the system. Water at the inlet to the cooling systems of the housing and the oil reflector must be supplied with a pressure of 0.3 MPa (3 kgf/cm2) to 0.5 MPa (5 kgf/cm2) and a temperature of plus 4°C to plus 25°C. The recommended cooling water consumption for the housing is 160 l/h, for the oil reflector it is 20 l / h. It is regulated by the outlet water temperature, which should not exceed plus 40°C. The water drain should be free (with a jet break).
Produced in: Kazan
Cabinet with table top LAB-500/800 TST
Cabinet with table top LAB-500/800 TST
Furniture for laboratory work. Cabinet with countertop Working surface: TRESPA TopLab Length, mm: 500 Depth, mm: 800 Height, mm: 900 EQUIPMENT cabinet - melamine 16mm thick 1 door 1 built-in shelf lock all-welded frame made of rectangular metal profile painted with white powder paint adjustable supports
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Exhaust cabinet for working with acids LAB-PRO SHVK 150.84.230 VI
Exhaust cabinet for working with acids LAB-PRO SHVK 150.84.230 VI
BASIC EQUIPMENT: Working box front guide posts – aluminum profile painted with powder paint (RAL 7035/RAL 5023), in the right rack there are a light switch and 2 splash–proof sockets with a 3.2kW cover (IP54) the front anti-spill side is acid-resistant polished stainless steel. AISI 316 steel rear, upper, side panels – metal painted with powder paint (RAL 7035) with the texture of shagreen leather inner capsule made of polypropylene lined with ceramic plates of the rear and side panels to a height of 380mm 2 dependent lifting screens – tempered glass in aluminum frames, lifting 0-780mm, do not change the dimensions of the cabinet when lifting the upper fixed screen – polypropylene on the top panel: LED dust– and moisture-proof lamp 2x22 W (IP65) is separated from the workspace by tempered glass with a thickness of 4mm flange d=250mm (distance from the back panel to the center of the flange - 170mm) switching box with automatic emergency power off 16A 3 exhaust levels easily removable exhaust visors counterweights are placed in the front pylon racks and are easily serviced Frame base collapsible frame made of rectangular metal profile painted with powder paint (RAL 7035) with the texture of shagreen leather service panel - aluminum profile painted with powder paint (RAL 5023) with the texture of shagreen leather adjustable supports
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Exhaust cabinet LAB-1200 SHVF-N
Exhaust cabinet LAB-1200 SHVF-N
Table top: FRIDURIT 20mm Length, mm: 1238 Depth, mm: 726 Height, mm: 2100 equipment Working box front anti–spill side - TRESPA TopLab sink-drain (ceramics, internal size 250*95*112mm), pipe for water the package includes a siphon corrugated 2 flexible eyeliners with a length of 1200mm housing – melamine with a thickness of 16mm lifting screen with the possibility of fixing at any height – tempered glass with a thickness of 5mm, lifting 0-700mm, increase the height of the cabinet at full lifting by 450mm
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Spring THERMOTEST holder-DP1-9/16
Spring THERMOTEST holder-DP1-9/16
Allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 9 to 16 mm. The design of the holder eliminates damage to glass thermometers. It is designed for calibration thermostats THERMOTEST-100 and THERMOTEST-300.
Produced in: Tomsk
Exhaust cabinet LAB-M SHV 90.74.210 VI
Exhaust cabinet LAB-M SHV 90.74.210 VI
Furniture for laboratory work. Exhaust cabinet made of chipboard Working surface: VITE 16mm Overall dimensions: Length, mm: 900 Depth, mm: 740 Height, mm: 2100 equipment Working box front anti–spill side - acid–resistant polished stainless steel AISI 316 housing - white chipboard with a thickness of 16mm guide posts – aluminum profile painted with powder paint dark gray (RAL 7011) 2 dependent lifting screens – tempered glass in aluminum frames, lifting 0-710mm, do not change the dimensions of the cabinet when lifting.
LOIP
Saint Petersburg
Produced in: Saint Petersburg