EVRAZCOMB – 2 in 1
EVRAZCOMB – 2 in 1
Purpose: Temperature measurement and sampling of molten steel. Scope of application: Oxygen converters, electric arc furnaces, induction furnaces, casting buckets Measuring range: from 1400 to 1800 °C - metal temperature Accuracy: 0 + 3°C at 1554°C The shape of the selected metal shape: Circle: thickness 12 mm Oval: thickness 12 mm Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium Measurement time: 8 sec Tube Length: from 100 to 2500 mm (other length is possible on request) Slag Cap: Steel, Aluminum, Cardboard Type of NSH: B, S, R
Produced in: Lipetsk
Laboratory electronic thermometer LTA-NF
Laboratory electronic thermometer LTA-NF
LTA-NF provides an error of ±0.05 °C in the range of measured temperatures from -50 to +200 ° C The minimum immersion depth of the sensor is 75 mm Overall dimensions of the electronic unit 80x75x100 mm Weight 0.25 kg
Produced in: Tomsk
Microphone condenser capsule MK-265
Microphone condenser capsule MK-265
It is designed to measure sound pressure in the air and is used in noise measuring equipment as a measuring transducer of infrasound, sound and ultrasonic pressure.
VIBROPRIBOR
Yaroslavl
Produced in: Yaroslavl
Electronic explosion-proof thermometer ExT-01/2-15
Electronic explosion-proof thermometer ExT-01/2-15
The thermometer sensor ExT-01/2-15 is made in the form of a fully submersible probe with a cable length of 15 meters. The thermometer has an explosion protection marking 0Ex ia IIB T4 Ga X and can be used in explosive zones 0, 1 and 2 of any classes of premises and outdoor installations in which the formation of explosive mixtures of categories IIA, IIB is possible. • Measurement range -50...+130 °C Minimum sensor immersion depth full immersion Overall dimensions of the electronic unit 135x65x40 mm Electronic unit weight 0.3 kg
Produced in: Tomsk
EVRAZCARB For measuring the carbon content in steel
EVRAZCARB For measuring the carbon content in steel
Purpose: Measurement of the percentage of carbon in steel Scope of application: Furnaces, buckets, cupola furnace Measuring range: from 0.01 to 2.00% carbon Accuracy: 0.01 %
Produced in: Lipetsk
EVRAZCOMB – 3 in 1
EVRAZCOMB – 3 in 1
Purpose: Measurement of temperature, oxygen activity and sampling of molten metal Scope of application: Oxygen converters, electric arc furnaces, induction furnaces, casting buckets Measuring range: from 1 to 2000 ppm O - metal oxidation from 1400 to 1800 °C - metal temperature from 0.010 to 0.200% - carbon content Accuracy: 0 + 3 °C at 1554 °C; (from 5 to 10) mV (depending on the oxygen activity level) The shape of the selected metal shape: Circle: thickness 12 mm Oval: thickness 12 mm Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium Measurement time: 8 sec Tube Length: from 100 to 2500 mm (other length is possible on request) Slag Cap: Steel, Aluminum, Copper, cardboard Type of NSH: B, S, R
Produced in: Lipetsk
Laboratory electronic thermometer LT-300-T
Laboratory electronic thermometer LT-300-T
The measurement range is -50...+300 °C. Up to +200 °C resolution 0.01 °C, error ±0.05 °C (Class C according to ASTM E2877). The minimum immersion depth of the sensor is 75 mm Overall dimensions of the electronic unit 75x80x35 mm Weight 0.2 kg
Produced in: Tomsk
Laboratory electronic thermometer LTA-K
Laboratory electronic thermometer LTA-K
A compact temperature sensor on an elastic cable allows you to get to the most inaccessible places of the certified equipment. LTA-K can be used as an accurate universal thermometer for contact temperature measurement of non-aggressive liquid, bulk and gaseous media. The error is ± 0.05 °C in the range of -50...+200 °C. Minimum sensor immersion depth full immersion Overall dimensions of the electronic unit 80x75x100 mm Weight 0.25 kg
Produced in: Tomsk
Laboratory electronic thermometer LT-300-N
Laboratory electronic thermometer LT-300-N
The measurement range is -50...+300 °C. Up to +200 °C resolution 0.01 °C, error ±0.05 °C (Class C according to ASTM E2877). The minimum immersion depth of the sensor is 75 mm Overall dimensions of the electronic unit 75x80x35 mm Weight 0.2 kg
Produced in: Tomsk
DIGITAL VACUUM METERS
DIGITAL VACUUM METERS
A digital vacuum gauge is a device for measuring pressure in rarefied gases. The device is used for the study of chemical and physical processes in the steel, chemical industry, for setting up machine units. It is used to evaluate the performance of electronic lamps, when filtering various media. In this article we will consider the principle and features of the device, its purpose and the specifics of the choice. Technical specifications: To measure vacuum in medium and highly discharged environments, it is necessary to select sensitive equipment. The device must have the following characteristics: Wide range of measured pressure (from 10-3 torr); High sensitivity: up to 1 atm; Absence of rubbing mechanical parts; Support for different display units: torrs, pascals, mmHg Support for different display units: torrs, pascals, mmHg; Visual electronic display; Insignificant power consumption.
Produced in: Yoshkar-Ola, Mari El
BOP-1c information processing and transmission units
BOP-1c information processing and transmission units
Purpose: processing of information received from detection units (primary converters); data transmission to the information network; data transfer to a portable computer (remote control tuning PN-PC); storage of threshold settings and parameters of detection units (primary converters); power supply and diagnostics of detection units (primary converters); output of threshold exceeding signals to built-in sound and LED alarms and to remote alarm units (BAS/BAS-1c); output of discrete signals (dry contacts); archiving of data in non-volatile memory.
Doza
Zelenograd
Produced in: Moscow