Search

178 products
View:
  • Selected: 1
    Applying
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • Applying
  • 60
    Names
    Loading...
  • 12
    Manufacturer
  • 13
    Made in
  • 10
    Additional
View:
178 products
Generator G6-46
Generator G6-46
Technical specifications: Frequency range, from 0.1 Hz to 1 Frequency range, from 0.1 Hz to 1 MHz Frequency setting error, ± 1 % Signal amplitude: - at a load of 600 ohms - without load, not less than 5 V (10 V span) not less than 10 V (20 V span)Smooth signal attenuation, at least 20 dB Frequency stability in 15 minutes, no more than 0.5% Hz Frequency setting error, ± 1 % Signal amplitude: - at a load of 600 ohms - without load, not less than 5 V (10 V span) not less than 10 V (20 V span) Smooth signal attenuation, at least 20 dB Frequency instability in 15 minutes, no more than 0.5 %
MNIPI
Minsk
Produced in: Belarus, Minsk
Power supply C35-80
Power supply C35-80
Operating Mode: Continuous Output stabilized current, A: 1-80 Output voltage, V: 0-35 Power supply: Three-phase 220/380 V 50 Hz Operating temperature range, °C: +10...+35 Storage temperature, °C: -20...+45 Relative humidity (without condensation), %: 90 Weight, kg: 5.3 Overall dimensions (W x H x D), mm: 390 x 75 x 200
INZHEKT
Saratov
Produced in: Saratov
Voltage converter V9-26
Voltage converter V9-26
Together with the conversion unit, a network AC-DC adapter module is supplied, as well as an intermediate power supply module.
NNPO im. M.V.Frunze
Nizhny Novgorod
Produced in: Nizhny Novgorod
Mobile Substation Laboratory TECHNOAS
Mobile Substation Laboratory TECHNOAS
The TECHNOAS substation laboratory consists of: Test facility • – Maximum rectified voltage up to 70 kV to 90 mA. • – Maximum AC voltage of the industrial frequency of 50 Hz to 100 kV to 175 mA. The IDP-10 dielectric loss meter unit is based on the Tangent-2000 meter and includes: • – Power transformer parameter meter. • – Measurement of losses and current XX. • – Measurement of short circuit losses and voltage. • – Determination of the transformation coefficient and the winding connection group. • – Measurement of the resistance of the windings to direct current. • – Formation of the test report. A milliohmmeter Measures DC resistance in inductive and non–inductive circuits in the range of 1 µΩ ÷ 10 kΩ at a current of 10A, as well as makes oscillograms of switching the contactor of a high-speed RPN device.
Produced in: Kolomna, Moscow region