Portable Gas chromatograph FGH-1
Portable Gas chromatograph FGH-1
from 573 000 ₽
The compounds to be determined are marginal and unsaturated hydrocarbons, alcohols, esters and esters, aromatic hydrocarbons, ketones, petroleum products, solvents, chlorine derivatives of hydrocarbons, etc. The list of substances is constantly updated, currently includes more than 100 ingredients. Detector one photoionization detector (PID) with Krypton vacuum ultraviolet lamp (VUV) One capillary column 25 m, phase SE, OB-61, FFAP, 624, etc. The threshold for determining benzene in air is 0.01 mg/m3 Average analysis time 15 min Powered by built-in batteries, 220 V mains Dimensions 460×350×120 mm (standard case), 487×370×180 (shockproof case) Autonomy of up to 300 analyses without replacement of carrier gas, up to 5 hours without charging batteries (for chromatograph without heated dispenser tap) Metrology Portable gas chromatographs of the FGH series, in particular the FGH-1 model, are registered in the State Register of Measuring Instruments under No. 16615-07 (certificate RU.C.31.004.A No.30175/1 dated 12/26/2012). All methods of analysis are certified in accordance with GOST R ISO 5725-6 and entered into the Federal Register.
EKAN
Moscow
FT-801 IR Fourier spectrometer
FT-801 IR Fourier spectrometer
It is designed for recording absorption spectra of solid, liquid and gaseous substances in the near and middle IR region (including drugs, lacquers and paints, petroleum products, explosives, pharmacological preparations, polymer films and fibers) with their subsequent identification, as well as for qualitative and quantitative analysis of mixtures containing several components.
SIMEKS
Novosibirsk
Produced in: Novosibirsk
Optical set-top box for working with light-guide IR probes
Optical set-top box for working with light-guide IR probes
FT-801 IR Fourier spectrometers can additionally be equipped with a special optical set-top box that allows efficient use of light-guide systems. 4 types of light-guide probes allow measuring transmission and reflection spectra in solid, liquid and gaseous media Modern IR light guides have high intrinsic transmittance and sufficient mechanical strength, which makes it possible to transfer measurements from the laboratory directly to production - to control the flow of technological processes, check the quality of raw materials and finished products. Application areas: · Chemical and microbiological industry · Pharmaceutical industry · Medicine and Cosmetology · Food industry · Petroleum products, fuels and lubricants · Criminology
SIMEKS
Novosibirsk
Produced in: Novosibirsk
Disposable board for anatomical specimens 30*45 cm
Disposable board for anatomical specimens 30*45 cm
from 8 000 ₽
Disposable board for anatomical specimens 30*45 cm Disposable boards for cutting anatomical specimens. Made of foam cardboard, according to their characteristics, they replace boards for cutting anatomical samples from other materials without loss of quality. They are convenient and easy to use and dispose of. The surface structure (coated coating) prevents the sample from sliding when cutting. It is possible to manufacture in various versions according to the customer's layout. The configuration of the product has a millimeter scale with digital markings: vertically and horizontally, circles of different diameters are applied , and a field for recording information is also provided. Color: White Size: 30*45cm. Packing: 20 pieces
VIS MED
Berdsk
Produced in: Novosibirsk region
Film for PCR dies, adhesive, for RealTime
Film for PCR dies, adhesive, for RealTime
The film is suitable for all types of thermal cycling, including real-time PCR. Pressure-sensitive adhesive film does not stick to gloves. This premium product guarantees tightness during amplification. Similar to imported samples. Temperature range: -70+100 °C Material: Polyolefin Packaging: 100 pcs.
VIS MED
Berdsk
Produced in: Berdsk, Novosibirsk region
Disposable board for anatomical specimens 20x30 cm.
Disposable board for anatomical specimens 20x30 cm.
from 4 800 ₽
The board for anatomical samples is 20x30 cm. Disposable boards for cutting anatomical specimens. Made of foam cardboard, according to their characteristics, they replace boards for cutting anatomical samples from other materials without loss of quality. They are convenient and easy to use and dispose of. The surface structure (coated coating) prevents the sample from sliding when cutting. It is possible to manufacture in various versions according to the customer's layout. The configuration of the product has a millimeter scale with digital markings: vertically and horizontally, circles of different diameters are applied , and a field for recording information is also provided. Color: White Size: 20x30 cm. Packing: 20 pieces.
VIS MED
Berdsk
Produced in: Novosibirsk region
Tripod "workplace" for single and stripped 0.2 ml tubes, 96 seats (plexiglass)
Tripod "workplace" for single and stripped 0.2 ml tubes, 96 seats (plexiglass)
Material of manufacture: Plexiglass Product Color: Transparent Tripod legs: rubber (to prevent sliding) For test tubes: 0.2 ml.
VIS MED
Berdsk
Produced in: Bryansk, Novosibirsk region
MAESTRO-αMS gas chromatograph by Interlab
MAESTRO-αMS gas chromatograph by Interlab
We offer expert laboratories of physicochemical methods of analysis a gas chromatograph with a quadrupole mass spectrometric detector «MAESTRO-αMS». Quadrupole GC-MS «MAESTRO-αMS» is in demand for targeted research (screening) and non-targeted search. In targeted studies, it is necessary to detect given target compounds in samples of various nature and origin at the level of residual amounts, for example, several picograms of the target compound in the injected 1 μl of liquid sample. Most often, targeted research is carried out in the following areas of laboratory screening: ecology, food safety, clinical monitoring, narcology, doping control, production control of various raw materials. In targeted studies, it is often required not only to confirm the presence of a compound in a sample, but also to determine the level of its content quantitatively, since both the list of target compounds and the permissible level of their presence in the sample are specified by regulatory documents. Quantitative analysis requires standards for the substances you are looking for. When conducting a non-target search, as a rule, it is required to analyze a sample of unknown composition, in other words, to find as many compounds as possible in the sample and identify (identify) each of them. Since the identification of a detected compound is carried out by comparing its experimental mass spectrum with the spectrum of a pure substance obtained under standard conditions, this task requires reference libraries of mass spectra of pure substances, as well as tools for working with mass spectra, for example: algorithms for cleaning experimental mass spectra from background and spectral noise (mass spectrum deconvolution algorithms), library search and comparison algorithms. An off-target search is called a qualitative analysis, since the researcher is primarily interested in the list of detected substances, and not in the quantitative assessment of their content in the sample. When creating MAESTRO-αMS, we took into account our own many years of experience in operating imported analogues. We have made the device inexpensive. We have made the device compact: The modern design of the device made it possible to make the MAESTRO-αMS really compact, so that the device occupies the smallest possible area on the laboratory table. The layout of the device allows you to remove the ion source on the front flange for cleaning and replacing the cathodes, if necessary. We have reduced the cost of operation: When developing the MAESTRO-αMS, we sought to increase the resistance of the device to sample matrices and use a minimum of consumable materials in order to eliminate downtime for maintenance and replacement. As a result, we have created an extremely stable ion source and a perpetual photomultiplier detector. We have created special software: Even at the first acquaintance with the software, it becomes obvious that being in the window of each button and each parameter to be changed is expedient and logical. Our software product was created for the convenience of the operator, so we implemented the necessary and eliminated the unnecessary. We used the principle of one active window, in which the operator moves sequentially step by step, performing hardware settings, setting the data collection method, subsequent processing algorithms, templates for presenting the results. MAESTRO-αMS offers a wide range of scanning modes, built-in algorithms for working with mass spectral data, convenient unloading of initial data arrays for their processing in specialized software packages, graphics export for presentations and scientific publications. You can use several libraries of mass spectra at the same time, or create your own for your typical tasks. Finally, we provide a 5-day training course for professionals who want to understand the theoretical foundations of the method and their implementation in the hardware of modern quadrupole GC/MS. The volume and depth of presentation of the material from the developers of the device is intended to lay the foundation for the effective use of «MAESTRO-αMS» in the future. Some technical characteristics of MAESTRO-αMS: • Instrumental detection limit (SIM, OFN @272 m/z ) < 10 fg; • Scan modes: scan for selected ions, full scan in a given mass range, combined scan mode; • The number of simultaneously connected libraries of mass spectra is at least 10.
Produced in: Moscow
GeneMack Strela Automatic Nucleic Acid Isolation Station
GeneMack Strela Automatic Nucleic Acid Isolation Station
1 supp.
The Strela automatic nucleic Acid isolation station is suitable for laboratories with a small sample flow seeking to optimize workflow and improve reproducibility of results. The station is being developed and assembled in Russia. Station Features: • Separation on magnetic particles – high yield of nucleic acids and excellent purity • The quality and concentration of the resulting DNA is sufficient for all molecular applications, including NGS • Ability to work with different types of samples, including complex samples (whole blood, FFPE, cfDNA, dry blood stains, saliva, hair, nails, etc.) • Simultaneous isolation of 1 to 13 samples • About 30 minutes per allocation, depending on the protocol • No overspending of plastic – load exactly as many cartridges as you are going to allocate samples • A large number of built-in protocols, the ability to program your protocols for different cartridges • User-friendly and intuitive interface • The station is compatible with cartridges from different manufacturers • 24/7 technical support in Russian Technical specifications Device Type: Desktop automatic device Minimum load: 1 sample Maximum load: 13 samples Reagent format: Bottled and sealed in individual cartridges Protocol execution time: From 16 to 60 minutes (depending on the allocation protocol program) Dosage volume: 25-1000 µl Dosing accuracy: No more than 5% CV Control: LCD Touch screen, 7 inches, 1025x600 Software language: Russian Heating unit with temperature control: from 30C to 80C (at room temperature+ 25C) UV lamp: Available Input voltage: 220V Overall dimensions (W x L x H): 54 x 57 x 61 cm Weight: 60 kg The installation location is only indoors Ambient operating temperature 15-40°C
Aivok
Zelenograd
Produced in: Moscow, Zelenograd
SPINNIX Centrifuge/Vortex, 2800 rpm, with a set of rotors
SPINNIX Centrifuge/Vortex, 2800 rpm, with a set of rotors
1 supp.
The Centrifuge/Vortex combines the functions of a vortex and a centrifuge in one device and is small in size, which saves space on the desktop or in the PCR box. Centrifuge characteristics:
  • Maximum rotation speed - 2800 rpm;
  • Maximum capacity - 12×1.5/2 ml (rotor R-1.5M);
  • vortex mode for one tube only;
  • timer - no;
  • covers - no;
  • operating mode - continuous and pulsed;
  • available rotors, pcs. - 3;
  • dimensions, W×D×H, mm – 120×170×120;
  • weight, kg - 1.4.
Aivok
Zelenograd
Produced in: Zelenograd
Chromatograph Milichrome A-02
Chromatograph Milichrome A-02
Overall dimensions: 550x230x350 mm Weight (without computer): ~17 kg Power consumption: up to 200 watts Warranty service : 1 year   Detector Two-beam spectrophotometer Spectral range – 190-360 nm Simultaneous detection at 1-8 wavelengths Cell volume – 1.2 µl Noise <0.0001 E.O.P. at 250 nm Drift <0.00005 E.O.P./hour at 250 nm Column Ø2x75 mm stainless steel The efficiency of the column is up to 6000 theoretical plates Thermostat Solid-state electric Set temperature from 35 to 90°C The discreteness of the temperature setting is 1 °C Temperature control error ±0.3°C      Pump Two-pronged, gradient The feed rate is from 5 to 1000 µl/min, the maximum pressure is 70 atm . The gradient is formed from 1 to 20 linear sections Automatic doser Automatic, programmable Number of test tubes – 46 The number of analyses in the series is from 1 to 200 The dosed volume is from 1 to 99 µl Test tubes made of glass with a volume of 200 µl Polyethylene tube stoppers Software OS: Windows® XP/7/10 Milichrome A-02™, Multichrome™, Alphachrome, Alphaspectrum
EkoNova
Novosibirsk
Produced in: Novosibirsk