Search

882 products
View:
  • Selected: 1
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • Applying
    Loading...
  • 263
    Names
    Loading...
  • 74
    Manufacturer
    Loading...
  • 40
    Made in
    Loading...
  • 66
    Additional
    Loading...
View:
882 products
Spectrophotometer UV-VIS PB2201
Spectrophotometer UV-VIS PB2201
from 1 000 000 ₽
Measuring functions Measurement of absorption, transmission, and reflection spectra Measurement of optical density, transmission coefficient and reflection coefficient at fixed wavelengths Determination of concentration at one, two, three wavelengths by factor, standard, schedule Multi-wave kinetic measurements Determination of concentration by programmed methods Calculation of color and chromaticity coordinates UVI spectrophotometers "SOLAR" operate in the ultraviolet, visible and near infrared regions of the spectrum. They are used in scientific laboratories, healthcare institutions, veterinary medicine, pharmaceuticals, ecology, biology, etc., in laboratories for quality control of products and raw materials in various sectors of the economy (industrial enterprises, agriculture, food industry, etc.) Removable cuvette holders and set-top boxes Accurate measurements Cost-effectiveness Touch screen Built-in printer Software support
SOLAR
Minsk
Produced in: Belarus, Minsk
OCTAVE-111 Noise meter, spectrum analyzer
OCTAVE-111 Noise meter, spectrum analyzer
Functionality ■ Sound level measurement: Class 1 according to GOST 17187-2010, IEC 61672-1 ■ Measures sound pressure levels in octave and third octave frequency bands ■ Has a metal body, resistant to external influences ■ Automatic recording of measurement results in memory ■ Non-volatile memory ■ Telemetry channel, remote control and operation of the device Features ■ Easy setup: one measurement mode, all values are measured simultaneously ■ Easy to manage: all results are grouped in two windows ■ Measurement of sound levels below 20 dBA ■ Affordable solution Application areas ■ Noise control in residential and public buildings ■ Noise control on the territory of enterprises and residential buildings ■ Production control ■ Vehicle inspection Complies with standards: - as a noise meter: GOST 53188.1-2019 (17187-2010, IEC 61672-1), Class 1 - as a spectrum analyzer: GOST R 8.714-2010, IEC 61260 (Class 1) Noise meter mode - Measuring range of sound levels, dBA: from 19 to 150* - Frequency characteristics: A, C, Z, AU, FI, G - Time characteristics: S, F, I, Peak, Leq * When equipped with 50 mV/Pa microphones and 12 mV/Pa Spectrum Analyzer mode with constant relative bandwidth - Frequency range of digital octave filters, Hz: 31.5 - 16000 - Frequency range of digital third-octave filters, Hz: 25 - 20000
Produced in: Moscow
UN-5 Magnetizing device
UN-5 Magnetizing device
from 83 000 ₽
The principle of operation of the magnetization device: The device consists of two compact blocks made of non-magnetic material connected by a flexible magnetic circuit. In each block there is a permanent magnet made of neodymium-iron-boron alloy (Ne-Fe-B). When installing the blocks on the surface of the part, a closed magnetic circuit is formed with the direction of the magnetizing field from one pole to the other. Above the defect scattering fields, magnetic powder particles are deposited to form an indicator pattern. Design features and advantages of the device for magnetic particle control UN-5 The delivery package with the device includes a portable case, an inter-pole jumper installed during transportation, and a liner for fixing blocks with permanent magnets. The UN-5 portable device does not require electrical power and therefore can be used where the supply of stationary power is difficult or impossible under regulatory documents: in the field, when working at height, for inspection of capacitive equipment operating under pressure, etc. - The device is easy to use, lightweight and small-sized, working with it does not require special physical and technical training from the operator; - Flexible magnetic core allows you to use the device to control parts of complex shape; - The UN-5 magnetizing device is distinguished by an increased quality of the indicator pattern and an increased control zone due to a reduced uncontrolled zone near the poles and an improved ratio of the normal and tangential components of the magnetic field (Russian patent No. 60732); - The technical characteristics of the device comply with Russian and foreign regulatory documents, this being the reason of its widespread use in more than 40 countries, including Germany, France, Brazil and Norway. When monitoring, the controlled area is the central part of the area located between the magnetic poles of the device. The width of the monitored area is determined by the width of the magnetic poles of the device and is approximately 60 mm. The length of the monitored section depends on the inter-pole distance. the dimensions of the controlled area are given depending on the device's inter-pole distance: Inter-pole distance, mm 95: 75 55 Controlled area between the working poles, mm: 60x60 40x60 25x55 The length of the defect detection zone depends on the distance established between the working poles of the magnet on the controlled product. Defects are not detected in the areas adjacent to the poles of the magnet. The length of these sections is 18 mm with an interpolar distance of 95 and 75 mm. With an interpolar distance of 55 mm these sections are 13 mm long. Scope of application: Magnetizing devices for magnetic powder flaw detection are used in many industries, including railway, water and aviation transport, in the construction and operation of pipelines, in chemical and petrochemical production. The flexible link between the magnetic blocks allows the control of products of complex shape, for example, cylindrical tanks, high-pressure apparatuses, main pipelines, etc. When checking for defects, the device can be used together with other auxiliary equipment for: - preliminary and subsequent demagnetization; - application of a magnetic indicator (which can be dry or in the form of an emulsion); - magnetoluminescent control (with ultraviolet lamps).
Produced in: Moscow
AK-1000 Acoustic calibrator
AK-1000 Acoustic calibrator
characteristics The AK-1000 is recommended for use with OCTAVE-101A, OCTAVE-101AM, OCTAVE-110A, OCTAVE-110A-ECO, OCTAVE-121, OCTAPHONE-110, OCTAVE-201, ECOPHYSICS-110A sound meters. The AK-1000 can be used for calibration of acoustic measuring paths with VMK-205, MK-265, MR-201, M-201, MK-233 microphones, and other ½-inch microphones. technical specifications Reproducible ultrasound, dB (rel. 20 µPa): 94 and 114 The limits of the permissible basic error of the reproducible ultrasound, dB: ± 0.25 Limits of the permissible additional error of the ultrasound caused by a change in ambient temperature in the operating temperature range, dB: ± 0.08 Frequency of the reproduced sound pressure, Hz: 1000 Limits of the permissible basic relative error of reproduction of the sound pressure frequency, %: ± 0.7 Limits of the permissible additional relative error of the sound pressure frequency caused by a change in ambient temperature in the operating temperature range, %: ± 0.07 Coefficient of nonlinear distortion, %, not more than: 2.5 Weight (with batteries), kg, no more than: 0.250 Overall dimensions (length×diameter), mm, no more: 158×35 Operating conditions: - ambient temperature, ° C: from minus 10 to 50 - relative humidity (at 40 ° C), %, not more than: 90 - atmospheric pressure, kPa: from 65 to 108
Produced in: Moscow
VE-26NP Eddy current structuroscope
VE-26NP Eddy current structuroscope
from 175 000 ₽
Distinctive features: The built-in thermometer allows you to take into account the influence of ambient temperature and improve the measurement accuracy. The built-in memory stores 4096 electrical conductivity measurement results for subsequent transfer to a PC. Specifications: Measuring range of the absolute value of specific electrical conductivity, MSm/m from 5 to 60
Measuring range of increments of electrical conductivity, MS/m from -9.99 to +9.99 Limit of permissible basic relative measurement error, % no more than 2 Permissible gap between the transducer and the surface of the controlled product, mm, no more than 0.25 Digital display of measurement results Power supply from RRZ type battery, V 9 Power consumption, mW, no more than 40 Operating temperature range, °C 5...40 Dimensions, mm 57*84*30 Weight, g 270±20
Produced in: Moscow
Multichannel digital measuring converter - recorder Ecofizika-500
Multichannel digital measuring converter - recorder Ecofizika-500
from 2 000 000 ₽
Ecofizika-500 is a multifunctional modern platform for building complex measuring systems. The developed software makes it possible to fully use the powerful hardware potential of the system in tasks requiring the use of complex computational algorithms. Ecofizika-500 is not just another multi-channel frontend designed to transfer unprocessed data to a computer; it is an independent measuring device capable of calculating a huge number of quantities in real time, storing them in its own memory and (or) issuing them to a telemetry channel. The device can be used, including in offline mode, as a data logger, which is very important when testing complex equipment that limits the presence of the operator. Ecofizika-500 has an approved type of measuring instrument and methodological support for measuring acoustic and vibrational quantities.
Produced in: Moscow