Search

463 products
View:
  • Selected: 1
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • Applying
    Loading...
  • 106
    Names
    Loading...
  • 40
    Manufacturer
    Loading...
  • 30
    Made in
    Loading...
  • 40
    Additional
    Loading...
View:
463 products
Photoionization (PID)
Photoionization (PID)
Partially universal detector. It is used for the analysis of most organic compounds, including aromatic and aliphatic (except methane) hydrocarbons, heterocyclic compounds, phenols, phthalates, pesticides, amines, ketones, aldehydes, esters, mercaptans. It does not register compounds whose ionization threshold is higher than 10.2 eV (for example, acetonitrile, methanol). Technical characteristic: 5.0*10`13 g/s for benzene
Produced in: Yoshkar-Ola, Mari El
Compact magnetic stirrer PL-R-atom USB, 2 liters. Primelab
Compact magnetic stirrer PL-R-atom USB, 2 liters. Primelab
The speed is set in the range from 150 to 2000 rpm, the timer is up to 99 minutes. Country of origin, Russia Orange color Protection class (according to DIN EN60529), IP21 Number of places for mixing, 1 Maximum volume of mixed liquid, 2 l Range of operating speeds of the motor shaft, 150-2000 rpm Connection – external temperature sensor PT1000 (sold separately) Power: USB port. Dimensions, weight Overall dimensions LxWxH, 160x148x48 mm Diameter of the working surface of the plate, 128 mm Device weight, 0.3 kg Contents of delivery Magnetic stirrer without heating PL-R-atom Operating manual combined with passport Anchor for stirrer in fluoroplastic sheath 5x30 mm; DC power supply, output voltage 9V, rated input voltage ~220V, 50Hz. USB cable
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
CRYOCONCENTRATION DEVICES
CRYOCONCENTRATION DEVICES
To determine small concentrations of substances, in some cases it is impossible to do without their concentration in special traps. An example of the need for such concentration is the determination of impurities in permanent gases (Ne, He, H2, Ar, O2, N2, Kr, Xe), the concentration of impurities is less than 1 ppm. Considering that these impurities can be not only hydrocarbons, but also permanent gases themselves, the use of direct detection of impurities by a catarometer is impossible. It is also not always possible to use highly sensitive but expensive detectors (GID, EDD, etc.). TECHNICAL CHARACTERISTICS The volume of the trap is 5 ml. The volume of the Dewar vessel (serial metal thermos) is 1200 ml. The concentration temperature range is from minus 88.6 (ethane) to minus 269 °C (helium). The ability to calibrate the chromatograph from the cylinder without disturbing the gas circuit. The possibility, simultaneously with concentration, to purify the gas intended for purging the trap from impurities (in a similar trap). Overall dimensions, no more than — 290 ×470 × 615 mm. Weight, not more than — 8 kg.
Produced in: Yoshkar-Ola, Mari El
SPINNIX Centrifuge/Vortex, 2800 rpm, with a set of rotors
SPINNIX Centrifuge/Vortex, 2800 rpm, with a set of rotors
1 supp.
The Centrifuge/Vortex combines the functions of a vortex and a centrifuge in one device and is small in size, which saves space on the desktop or in the PCR box. Centrifuge characteristics:
  • Maximum rotation speed - 2800 rpm;
  • Maximum capacity - 12×1.5/2 ml (rotor R-1.5M);
  • vortex mode for one tube only;
  • timer - no;
  • covers - no;
  • operating mode - continuous and pulsed;
  • available rotors, pcs. - 3;
  • dimensions, W×D×H, mm – 120×170×120;
  • weight, kg - 1.4.
Aivok
Zelenograd
Produced in: Zelenograd
LIQUEFIED GAS METERING VALVE
LIQUEFIED GAS METERING VALVE
The metering valve for the analysis of liquefied gas (KDSG) is designed for the introduction of liquefied gas or other liquid under excessive pressure into the evaporator of the chromatograph. KDSG is a 4-way crane, in which a dose of a certain volume is installed. The tap is installed on the evaporator of the chromatograph. A dose of any volume can be installed on the tap. Dose change can be performed by the operator. The amount of the dose volume is indicated on the tag. Technical specifications The dose volume is from 0.25 to 4.0 µl (at the request of the consumer, the dose volume can be increased up to 10 µl). The tap temperature is no more than 150 °C. The pressure in the crane line is not more than 0.48 MPa. The angle of rotation of the crane handle is 90 °C.
Produced in: Yoshkar-Ola, Mari El
METERING VALVE FOR GAS SAMPLES
METERING VALVE FOR GAS SAMPLES
The metering valve for the introduction of gas samples is designed for the introduction of gas under excessive pressure into the chromatograph. Cranes differ in the number of moves (4, 6, 8, 10, 12) and have two provisions "Selection" — "Analysis". In addition to dosing, cranes can be used to switch chromatographic columns, elements of gas circuits, etc. The tap can be installed either on the side panel of the chromatograph, or directly into the analytical module instead of, or together with the evaporator of the chromatograph, while it is used as a back-purge tap or for hot sample entry. Additionally, the tap for hot entry can be equipped with heated pipelines. technical specifications The dose volume is from 0.25 to 5.0 ml (at the request of the consumer, the dose volume can be increased to 10 ml and reduced to 0.1 ml). The maximum temperature of the tap is no more than 160 °C. The pressure in the crane line is not more than 0.48 MPa. The angle of rotation of the crane handle — depending on the number of strokes.
Produced in: Yoshkar-Ola, Mari El
EQUILIBRIUM STEAM DISPENSER DRP-10(DRP-13)
EQUILIBRIUM STEAM DISPENSER DRP-10(DRP-13)
The equilibrium steam dispenser "DRP-10 (DRP-13)" is designed for the introduction of volatile components from matrices into the chromatograph, the introduction of which into the chromatograph is impossible or undesirable. Examples of such matrices are natural, drinking and waste water, soil, biological fluids, food and beverages, various polymers, building materials, pharmaceutical products, etc. The use of DRP-10 (DRP-13) makes it possible to avoid contamination of the evaporator, column and chromatograph detector with non-volatile or non-volatile substances, to avoid the consumption of solvent required for extraction, to increase the reproducibility of analyses. Technical specifications The temperature of the thermostat of containers with a breakdown is from ambient temperature to 150 °C. The error of maintaining the temperature is not more than 0.1 ° C. The volume of the container with the sample is 20 ml, it is possible to use vials from 6 to 40 ml. The number of simultaneously thermostatically controlled containers is 4. The dosed volume of the equilibrium vapor is up to 2 ml. The temperature of the syringe is from ambient temperature to 150 °C. The gas consumption for purging is from 5 to 300 ml/min. Electric power supply from the AC network with voltage (220index) V, frequency (50 ± 1) Hz. Overall dimensions (width × depth × height) — 350×270×170 mm. Power consumption — no more than 360 VA. Weight — no more than 6.5 kg.
Produced in: Yoshkar-Ola, Mari El
DISPENSER "EVEN 4000"
DISPENSER "EVEN 4000"
The dispenser "DAZH 4000" is designed for automatic insertion of liquid samples into the evaporator of the gas chromatograph, provides: control from the software, setting variable parameters of algorithms for washing and sample entry, storing the operating parameters of the dispenser in the method. Technical characteristics: The number of vials in the carousel, pcs up to 30 The volume of installed vials, ml 0.1-2ml Number of injections from one vial 1-99 Replaceable syringes in volume, ml 10, 100, 250, 500 The volume of the injected sample, ml : from 0.01 to 500 The discreteness of setting the sample volume, µl: from 0.01 to 1 Sampling and insertion rate, µl/s: from 0.01 to 5000 The speed of needle insertion into the evaporator, discret 3 Immersion depth in the vial and evaporator, variable up to the length of the syringe needle, mm 1 – 99 The discreteness of the dive depth setting, mm 0,1 The number of pumping during sampling 0-15 Number of solvent washes 0-15 Needle exposure time in the evaporator, sec 0-99 The discreteness of setting the needle shutter speed, sec 1,0 Sample input modes Simple insertion, Sandwich, Solvent sandwich, Sandwich with internal standard Flushing mode From the vial Supply voltage, V (frequency, Hz) 220 (50) Power consumption, W 154 Weight, kg, no more 2,9 Overall dimensions, mm 175x270x420 Communication with the computer Ethernet
Produced in: Yoshkar-Ola, Mari El
Sigmed MC-02 Microcentrifuge
Sigmed MC-02 Microcentrifuge
The centrifuge is designed in two versions: - Version 1: maximum rotor speed at 8000 rpm (6000 x G) - Version 2: maximum rotor speed at 12000 rpm (9000 x G) RPM and casting g-load are displayed on the readout
Produced in: Kaluga region, Obninsk
Radiation Monitoring Station Zastava-1
Radiation Monitoring Station Zastava-1
Devices of a new generation, automated stations of continuous radiation monitoring Zastava-1 are designed to organize continuous effective monitoring of the radiation situation and notification of radiation hazards. The stations have up to three independent measurement channels, which allows monitoring simultaneously in several zones. The stations support remote monitoring - they have a connection to a local computer network, Internet access.
NPP "ELEKTRONNYE PRIBORY"
Naberezhnye Chelny
Produced in: Tatarstan, Naberezhnye Chelny