Search

456 products
View:
  • Selected: 1
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • Applying
    Loading...
  • 105
    Names
    Loading...
  • 42
    Manufacturer
    Loading...
  • 30
    Made in
    Loading...
  • 47
    Additional
    Loading...
View:
456 products
Smear painting device automatic portable "Pros-Ap"-01 MiniMed
Smear painting device automatic portable "Pros-Ap"-01 MiniMed
from 120 000 ₽
It is intended for painting blood smears or other biological preparations on slides - slides by the group method (slides are placed in holders) according to a given technological program in diagnostic and research laboratories. Cassettes with fixed slides successively go through 5 working stages: 1) Pre-drying of freshly prepared preparations; 2) Fixation with pre-painting; 3) Basic coloring; 4) Flushing; 5) Drying. The cassettes are moved to the next position by the forward-return movement of the trays. The time of each stage is the same. It can be set when ordering the device. Factory setting – 5 minutes. The total duration of all stages is 20 minutes. The coloring process is carried out along a linear trajectory. Slides with a smear should be placed in special cassettes and fixed by turning the eccentric lever. Fill the baths with reagents and install them in the device at the specified places. Place the slide cassette on the pre-drying starting position. If the preparations are dry, the cassette with slides should be immediately placed in a bath with a retainer. The time of each stage is 5 minutes. The whole procedure of painting and drying takes no more than 20 minutes. With sequential installation, the device can process up to 12 cassettes, i.e. up to 120 slides per hour.
MiniMed
Suponevo
Produced in: Bryansk region
Adhesive film for EIA microplate 135*82 mm
Adhesive film for EIA microplate 135*82 mm
from 900 ₽
Adhesive Film for EIA tablets. Non-sterile. Optically transparent. The film securely seals the tablet. Moisture-proof, non-toxic, prevents excessive evaporation of water from the wells of the microplate, sedimentation of reagents on their walls, and as a result, the edge effect. Prevents false positive results during EIA. There is 1 notch in width. Thickness: 80 microns. Size:135*82mm Composition: PVC Application temperature: -40°C to +80°C Color: Transparent Packaging: 100 pcs.
VIS MED
Berdsk
Produced in: Berdsk, Novosibirsk region
Tampon-probe MiniMed non-sterile, probe polypropylene, tampon viscose, TU 32.50.50-035-29508133-2020 , pack.100/20tys.pcs
Tampon-probe MiniMed non-sterile, probe polypropylene, tampon viscose, TU 32.50.50-035-29508133-2020 , pack.100/20tys.pcs
from 95 ₽
It is intended for taking and storing samples of biological material for the purpose of safe transportation to the laboratory for analysis. It is convenient for taking flushes, including sanitary ones. Non-sterile.
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with K2-EDTA and separation gel, 8 ml, 16×100mm, purple, PET, pack.100 pcs.
Vacuum tube MiniMed with K2-EDTA and separation gel, 8 ml, 16×100mm, purple, PET, pack.100 pcs.
from 1 710 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Gel is a special material designed to form a stable barrier between the cellular components of blood and serum during centrifugation. Material for research............... EDTA-blood, plasma Scope of application............................ hematological examination of whole blood
MiniMed
Suponevo
Produced in: Bryansk region
Tampon-probe MiniMed non-sterile, probe wood, tampon cotton, TU 32.50.50-035-29508133-2020 , pack.100/20tys.pcs
Tampon-probe MiniMed non-sterile, probe wood, tampon cotton, TU 32.50.50-035-29508133-2020 , pack.100/20tys.pcs
from 113 ₽
It is intended for taking samples of biological material, with the possibility of their subsequent safe transportation to the laboratory for analysis. Non - sterile
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with coagulation activator, 8ml, 16×100mm, orange, PET, pack.100 pcs.
Vacuum tube MiniMed with coagulation activator, 8ml, 16×100mm, orange, PET, pack.100 pcs.
from 1 021 ₽
The walls of the tubes are coated with a dry clot formation activator (silicon dioxide) to accelerate blood clotting. Mixing blood with it does not affect the result of tests. The acceleration of the blood clotting process significantly reduces the preparation time of the biological sample. Material for research............... blood serum Scope of application............................ blood serum research in biochemistry, immunology Centrifugation................................ 1000 - 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Exposure device UER-03 (TU 26.51.70-003-63790925-2021 )
Exposure device UER-03 (TU 26.51.70-003-63790925-2021 )
1 supp.
The principle of operation of the device UER-03: The principle of operation of the device is based on the creation of equal conditions for all exposed samples during biotesting. It is achieved by rotating the cassette with the test culture samples of crustaceans installed in it around the central axis. Since the sample cassette is oriented obliquely, when it rotates, there is an active gas exchange between the surrounding air and water samples. As the result, test organisms in test tubes are provided with sufficient oxygen concentration in the medium during the entire exposure period. The rotation speed of the cassette is chosen so as not to have a stress effect on the crustaceans. The device operates in continuous mode and does not require additional intervention in the process of exposing the crustacean culture. The required conditions for temperature and light irradiation can be provided only when the device is installed in the climatostat. Used in techniques: - Methodology for determining the toxicity of water extracts from soils, sewage sludge and waste, drinking, sewage and natural water by the mortality of the test object (Daphnia magna Straus). MON F 14.1:2:4.12-06 / 16.1:2.3.3.9-06 FR.1.31.2009.06641. - Methodology for determining the toxicity index of nanopowders, products made of nanomaterials, nanopoints, waste and sewage sludge containing nanoparticles, according to the mortality of the test organism Daphnia magna Straus. FR.1.39.2010.09102 And it can also be used in other suitable techniques.
Evropolitest
Ivanteevka
Produced in: Moscow region
Vacuum tube MiniMed with K2-EDTA, 9 ml, 16×100mm, purple, PET, pack.100 pcs.
Vacuum tube MiniMed with K2-EDTA, 9 ml, 16×100mm, purple, PET, pack.100 pcs.
from 1 021 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Material for research............... stabilized EDTA whole blood /EDTA plasma.
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with coagulation activator and separation gel, 5ml,13*100 mm, yellow-orange, glass,pack of 100 pcs.
Vacuum tube MiniMed with coagulation activator and separation gel, 5ml,13*100 mm, yellow-orange, glass,pack of 100 pcs.
from 1 339 ₽
Test tubes are used for blood sampling in biochemistry and immunology. During centrifugation, the gel forms a strong barrier for 48 hours between the clot and the serum. The gel tubes must be centrifuged no later than 2 hours after blood collection. Research material............... blood serum Scope of application............................ serum research in biochemistry, immunology Centrifugation.............................. 1500-2000 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
rhAlbumin
rhAlbumin
from 5 000 ₽
Human Serum Albumin (HSA) is the main human plasma protein and has many physiological properties due to its unique structure.
Produced in: Moscow
LAMPIX8 Portable instrument for real-time isothermal DNA amplification,  1 channel, 8×0,2 ml
LAMPIX8 Portable instrument for real-time isothermal DNA amplification, 1 channel, 8×0,2 ml
1 supp.
LAMPIX 8 uses the method of Loop-Mediated Isothermal Amplification of DNA and RNA (LAMP and RT-LAMP) for genetic analysis of any kind.
Key features.
  • Compact: supports 8 standard 200μL tubes in a single test run.
  • Portable:provides genetic testing in an on-site or mobile laboratory.
  • Fast: Result within 15 minutes after the start of the analysis.
  • Real-time: Detection of the results with our built-in software.
  • Open system: can work with any test kits with FAM / SYBR dyes for isothermal amplification.
  • Flexible: possibility to adjust settings for your research purposes.
LAMP TEST KITS: LAMP LYME KIT (Detection of the B.burgdorferi in ixodid ticks) *sensitivity from 50 copies of DNA. SARS-CoV-2 test (COVID-19).
Technical Specifications.
  • Excitation source 8 LEDs,
  • Excitation detection 8 photodiodes,
  • Number of Fluorophores 1 FAM/SYBR/EvaGreen,
  • Excitation wavelength 470 nm,
  • Detection range 510-530 nm,
  • Sample capacity 8 х 200 μl tubes,
  • Tube type separate tubes / strips with flat lid,
  • Operating temperature range 37˚C to 75˚C with 0.5˚C resolution,
  • Lid type heated lid,
  • Heated lid temperature range 37.0 ˚C to 75.0 ˚C with 0.5˚C resolution,
  • PC connection USB type С port,
  • Dimensions W × D × H 115 х 80 х 65 mm,
  • Weight 250 g,
  • Power 12 V / 18 W external power supply / power bank,
  • Software Operating system Win 7-10.
    Aivok
    Zelenograd
    Produced in: Moscow, Zelenograd
    Cultivator KVM-08 (TU 26.51.70-003-63790925-2021 )
    Cultivator KVM-08 (TU 26.51.70-003-63790925-2021 )
    from 240 000 ₽
    1 supp.
    This cultivator is an improved model of cultivators of the KVM type of earlier execution. Previously, KVM cultivators had a narrowly focused orientation to the Grigoriev Yu.S. methodology. 14.1:2:3:4.10-04 / 16.1:2:2.3:3.7-04; FR.1.31.2009.06642 (biotest on the reaction of a thermophilic strain of chlorella algae, test function - cell growth in relation to control. the duration of the test is 22 hours, toxicity criteria: 20% suppression of growth. 30% - stimulation of growth in relation to control). The Europolitest company strives to provide Russian laboratories with the best equipment with extensive functionality. Today. we have released a new cultivator KVM-08 with touch control. It can still be used according to the above method (in the same mode - power from the 220V household network via the power supply) At the same time, this cultivator can be connected to the on-board network of climatostats (P2, B3 and B4). In this case, it can maintain the temperature control at the level of 20 gr. With (despite the fact that the climatostat will be configured to maintain 18 gr. S). That is, when connecting this cultivator with the on-board network of the climatostat, the cultivator allows you to work in a wider temperature range (20 - 32 gr. S) And when working from 220V - in the range (27 - 40 gr. S.) In such a way thus, this cultivator allows you to consistently carry out two techniques: 1). 14.1:2:3:4.10-04 / 16.1:2:2.3:3.7-04; FR.1.31.2009.06642 (when operating from 220 V without using a climatostat) 2). RD 52.24.905-2020 (when the cultivator is connected to the on-board network of climatostats (P2, B3 and B4) In addition, with new characteristics and functionality, this cultivator is a convenient research tool. In addition to the preset modes for biotests according to the two above methods, the cultivator has 3 three user modes for free programming by the operator Allows you to configure and "flash" individual parameters: - temperature control : any value from the range of 20 - 40 gr. C (take into account the restrictions for work from 220 or from the board. climatostat networks) - lumostating : the maximum value is 16,000 Lux, the cultivator allows you to adjust from 0 to 100 % - rotation speed of the drum with penicillin vials (24 pcs.) : 0 - 60 rpm - duration of exposure: 0 - 240 h (discreteness of 1 min) - sound notification of the end of the specified exposure time
    Evropolitest
    Ivanteevka
    Produced in: Moscow region