Biosafety cabinet BA-Safe 150
Biosafety cabinet BA-Safe 150
Biosafety cabinet Belaquilon BA-safe 150 (for biological protection). The Class II Type A2 biological safety cabinets are designed to reduce the risk of infection to the operator during work with dangerous or potentially dangerous microorganisms and to protect the specimen, is the result of the production of biological safety cabinets based on user feedback. Technical specifications Voltage, frequency, 230V ±10%/Hz Engine 1-phase 230 V, 50 Hz, speed 1150 rpm UV lamp TUV UV lamp, UV lamp timer, 6000 hours of operation Wavelength 254 nm Number of LEDs, pcs at least 380 Lighting power, 55 W Work area illumination at least 1500 lux, brightness adjustable, color of luminous flux 6000 K (cold white light) Internal dimension of the working area, at least 1530×504 mm Working height of front screen elevation, 200 mm Max. height of front screen elevation, 510 mm Frontal screen position alarm Audible position warning. Warning appears on display Outer dimension, mm 1668.5x766.2x1506.6 Height of base, mm 690
Produced in: Belarus, Minsk
Vacuum tube MiniMed with K3-EDTA and separation gel, 1ml, 13×75mm, purple, PET, pack.100 pcs,
Vacuum tube MiniMed with K3-EDTA and separation gel, 1ml, 13×75mm, purple, PET, pack.100 pcs,
from 858 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Gel is a special material designed to form a stable barrier between the cellular components of blood and serum during centrifugation. Material for research............... EDTA-blood, plasma Scope of application............................ hematological examination of whole blood
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with K2-EDTA, 4 ml, 13×100mm, purple, PET, pack.100 pcs,
Vacuum tube MiniMed with K2-EDTA, 4 ml, 13×100mm, purple, PET, pack.100 pcs,
from 696 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Material for research............... stabilized EDTA whole blood /EDTA plasma. Scope of application............................ hematological examination of whole blood
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with K3-EDTA, 1ml, 13×75mm, purple, PET, pack.100 pcs
Vacuum tube MiniMed with K3-EDTA, 1ml, 13×75mm, purple, PET, pack.100 pcs
from 690 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Material for research............... stabilized EDTA whole blood /EDTA plasma.
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with sodium citrate 3.8%, 2.7 ml,13*100 mm, blue, PET,pack.100 pcs,
Vacuum tube MiniMed with sodium citrate 3.8%, 2.7 ml,13*100 mm, blue, PET,pack.100 pcs,
from 330 ₽
The test tubes contain a buffer solution of sodium citrate, which is an anticoagulant. The ratio of citrate to the amount of blood taken is 1:9. Material for research............... citrate plasma, blood Scope of application............................ coagulation study Centrifugation................................ 2000 - 2500 g - 10-15 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with sodium heparin, 4 ml, 13×100 mm, green, PET, pack.100 pcs,
Vacuum tube MiniMed with sodium heparin, 4 ml, 13×100 mm, green, PET, pack.100 pcs,
from 804 ₽
Test tubes are used to count blood cells and study plasma parameters. When mixed with the collected material, heparin blocks the activity of thrombin and inhibits the transition of soluble fibrinogen to insoluble fibrin, inactivating irreversible clotting factors. Material for research............... heparinized blood, plasma Scope of application............................ immunology, hematology Centrifugation................................ 1000 - 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with K3-EDTA, 5 ml, 13×75mm, purple, glass, pack.100 pcs
Vacuum tube MiniMed with K3-EDTA, 5 ml, 13×75mm, purple, glass, pack.100 pcs
from 1 163 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Material for research............... EDTA-blood, plasma Scope of application............................ hematological examination of whole blood
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with K2-EDTA,, 5 ml, 13×75mm, purple, PET, pack.100 pcs
Vacuum tube MiniMed with K2-EDTA,, 5 ml, 13×75mm, purple, PET, pack.100 pcs
from 627 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Material for research............... stabilized EDTA whole blood /EDTA plasma.
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with K2-EDTA, 3 ml, 13×75mm, purple, glass, pack.100 pcs
Vacuum tube MiniMed with K2-EDTA, 3 ml, 13×75mm, purple, glass, pack.100 pcs
from 1 163 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Material for research............... EDTA-blood, plasma Scope of application............................ hematological examination of whole blood
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with coagulation activator, 2ml, 13×75mm, orange, glass, pack.100 pcs
Vacuum tube MiniMed with coagulation activator, 2ml, 13×75mm, orange, glass, pack.100 pcs
from 1 592 ₽
The walls of the tubes are covered with a dry clot formation activator to accelerate blood clotting. Mixing blood with it does not affect the result of tests. The acceleration of the blood clotting process significantly reduces the preparation time of the biological sample. Research material............... blood serum Scope of application............................ blood serum research in biochemistry, immunology Centrifugation................................ 1000 - 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with coagulation activator and separation gel, 4ml,13*100 mm, yellow-orange, PET,pack.100,
Vacuum tube MiniMed with coagulation activator and separation gel, 4ml,13*100 mm, yellow-orange, PET,pack.100,
from 902 ₽
Test tubes are used for blood sampling in biochemistry and immunology. During centrifugation, the gel forms a strong barrier for 48 hours between the clot and the serum. The gel tubes must be centrifuged no later than 2 hours after blood collection. Material for research............... blood serum Scope of application............................ serum research in biochemistry, immunology Centrifugation.............................. 1500-2000 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Mercury Monitor type RA-915AM for Natural Gas Analysis
Mercury Monitor type RA-915AM for Natural Gas Analysis
1 supp.
Technical specifications: Absorption coefficient of mercury vapor by the built-in sorption filter, %, not less than 98 Volume flow rate of the analyzed gas at the monitor inlet, dm3/min, not less than 4 Monitor power supply from AC mains: voltage, V frequency, Hz 220 ± 22 50 ± 1 Power consumption, In × A, not more than 150 Overall dimensions (LXC), mm, no more 665x482x222 Weight, kg, not more than 25 Operating conditions: - ambient temperature, °C from 10 to 35 - relative humidity (at 25 °C), %, not more than 80 - atmospheric pressure, kPa from 84 to 106.7 - relative humidity of the analyzed gas (at 20 °C), %, not more than 99 Average time to failure, h 12000 Average service life, 5 years
Lumeks
Saint Petersburg
Produced in: Saint Petersburg