Desktop Diffractometer HUMMINGBIRD
Desktop Diffractometer HUMMINGBIRD
The device is designed to analyze the phase composition and structural state of polycrystalline objects of various origins.
Burevestnik
Kolomyagi
Produced in: Saint Petersburg
Two-jet arc plasmatron "Torch"
Two-jet arc plasmatron "Torch"
The plasmatron is designed for direct atomic emission spectral analysis of powder samples. The excitation of atoms occurs in a DC argon arc plasma. Weak matrix effects and low detection limits make it possible to use this excitation source for the analysis of various samples, both with mineral and organic matrix.
Produced in: Novosibirsk
Universal spectrometer "Express"
Universal spectrometer "Express"
The spectrometer is designed to perform quantitative and qualitative spectral analysis of various substances and materials (powders, metals, solutions) in factory and research laboratories. The spectrometer is compact due to the vertical arrangement of the Paschen-Runge optical system. It consists of two MAES analyzers with 10 lines of photodiodes installed on a circle with a radius of 520 mm, a non-classical concave diffraction grating, a special table with a built-in computer and a spectrum excitation source.
Produced in: Novosibirsk
Quenching oil tank BZM 10.12.15/06
Quenching oil tank BZM 10.12.15/06
Oil quenching tanks of the tank type are designed for quenching cooling of products heated to the quenching temperature in oil at temperatures up to 90 ° C in stationary conditions. The workspace environment is oil. Quenching oil tanks "BZM-10.12.15/0.6" are designed to remove the steam jacket from the surface of the part in oil with mixing in a laminated flow with maintaining the temperature of the liquid. Water, oil, or polymer liquid can be used as a working fluid in the quenching oil tanks "BZM-10.12.15/0.6". The tank is welded from a metal profile and is a rigid power structure. U–shaped heating elements with a capacity of up to 40 kW are installed on the inner side. Cooling is carried out by means of a heat exchanger (coil) installed in the working space. Cold process water from the mains is used for cooling. Optionally, tanks (or a complex of tanks) can be equipped with a chiller or a cooling tower. The liquid level maintenance system ensures a constant level of liquid in the tank. A level sensor is installed to monitor the level. When the liquid level in the tank decreases, the liquid is refilled automatically. Mixing of the liquid in the tank is provided by means of a stirrer located at the bottom.
Produced in: Tula
Table for working with powder samples
Table for working with powder samples
A table with a stone countertop and a stainless steel sheet located in the center with a perforation through which exhaust ventilation creates a constant flow of air carrying away sample particles
Produced in: Novosibirsk
Spectroanalytical tripod "Globula"
Spectroanalytical tripod "Globula"
The video camera and servos of the electrode holders built into the tripod are designed to automatically maintain the interelectrode gap during the evaporation of the sample by computer analysis in real time of the image of the arc discharge, as well as the initial setting of this gap relative to the optical axis. The electrode holders are cooled with water using a closed-cycle cooling unit.
Produced in: Novosibirsk
Small-sized multichannel spectrometer - "Hummingbird-2"
Small-sized multichannel spectrometer - "Hummingbird-2"
The spectrometer was created according to the Cherni-Turner scheme based on a flat diffraction grating and an MAES analyzer with one line of photodetectors. It has increased photometric accuracy due to cooling and temperature stabilization of the photodetector range, as well as due to its shell-less design, in which there is no re-reflection of radiation on the cover glass and the background level in the recorded spectrum decreases. The optical scheme and design of the spectrometer are optimized to obtain a high-quality spectrum with a low level of background radiation in any of the regions lying in the spectral range of 190-1100 nm. The choice of the working area is carried out by changing and rotating the diffraction gratings. The sealed case of the spectrometer is filled with an inert gas. The radiation is injected into the spectrometer using a quartz capacitor or a fiber-optic cable with an SMA-905 connector. The optical scheme and design of the spectrometer are protected by patents.
Produced in: Novosibirsk
Electric arc installation for the analysis of powder samples by the method of spillage injection "Stream"
Electric arc installation for the analysis of powder samples by the method of spillage injection "Stream"
The installation is designed to excite atomic emission spectra of powder samples in an electric arc by the spillage-injection method. It provides high performance of routine analyses, has a low consumption of graphite electrodes and is used in conjunction with any spectral devices – "Grand", STE-1, DFS-458, MFS-8, PGS-2, etc.
Produced in: Novosibirsk
Water washing tanks
Water washing tanks
The product is designed for cleaning materials in a water environment with the addition of alkali at a temperature of up to 90 ° C by mixing in a laminated stream with maintaining the temperature of the liquid and automatic removal of the oil film. The tank is welded from a metal profile and is a rigid power structure. On the inside, U–shaped heating elements are installed to maintain the set temperature. Temperature control is performed by a digital device. The integrity of the heaters is monitored by a standard ammeter. The liquid level maintenance system ensures a constant level of liquid in the tank. When the liquid level in the tank decreases, the liquid is supplied automatically through the built-in valve (optional). To do this, a level sensor is installed in the tank. If the level drops unacceptably, the heating is turned off. A skimmer is installed to remove the oil film. The tank is equipped with a bubbling device. It can be equipped with a circulation pump.
Produced in: Tula
Atomic emission spectrometer Iskroline 500
Atomic emission spectrometer Iskroline 500
The main advantage of a mobile spectrometer is the ability to measure the composition of alloys not only in the laboratory on specially prepared samples, but also directly in a workshop or warehouse without cutting the product or workpiece.
Iskrolajn
Saint Petersburg
Produced in: Saint Petersburg