Search

287 products
View:
  • Selected: 0
    Applying
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 1
    Additional
All filters
  • 8
    Applying
  • 26
    Names
    Loading...
  • 7
    Manufacturer
  • 8
    Made in
  • Additional
View:
287 products
3KN-2,5NZ Vacuum Inlet valve
3KN-2,5NZ Vacuum Inlet valve
The 3KN-2,5 intake valve includes a nut, the filter is installed in the housing between the two rings. The opening of the inlet valve 3KN-2,5 is carried out when the electromagnet coil is de-energized and the armature returns to its original position under the mechanical pressure of the spring. The closure of the 3KN-2,5 intake valve occurs when an electric voltage of a certain power is applied to the terminals of the coil. The anchor is involved in the shoe, ensuring the closure of the ductal canal.
Produced in: Kazan
Laboratory vacuum drying cabinets SHSV residual pressure in the chamber 0.05 mm Hg SHSV-65V/3.5
Laboratory vacuum drying cabinets SHSV residual pressure in the chamber 0.05 mm Hg SHSV-65V/3.5
The electric vacuum drying cabinet SHSV-65V/3.5 is designed for drying and heating various materials in air and in vacuum at a maximum temperature of 350 ° C. In the model with the index "C", the door is made of heat- resistant glass. Technical specifications The electric cabinet operates at ambient temperature from 10 to 35 ° C and relative humidity up to 80% at 25 ° C Operating temperature- 350 ⁰C Power consumption - 2500 W Dimensions of the working chamber-Ø430x430 mm Dimensions WxDxH- 680x950x670 mm Weight - 115* kg (* - mass with microprocessor unit and pump)
MIUS
Tula
Produced in: Tula
2VVN2-50 Water ring vacuum pump
2VVN2-50 Water ring vacuum pump
The use of a 2VVN2-50(H) water-ring vacuum pump for pumping out water-gas mixtures is allowed only if the bulk of the water is separated and discharged at the pump entrance. Failure to comply with this requirement may lead to unacceptable overload of the electric motor and destruction of the working parts of the 2VVN2-50(H) pump. The 2VVN2-50(H) vacuum water ring pump is manufactured in the climatic version of UHL 4 and O4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, meets the requirements of technical specifications TU 3648-015-00218526-2000, designed and manufactured taking into account the requirements of GOST R 52615-2006. The quality of electricity must meet the requrimemnts of GOST 32144-2013.
Produced in: Kazan
Vacuum drying cabinet SNVS - 215/3,5
Vacuum drying cabinet SNVS - 215/3,5
They are designed for carrying out various technological processes at temperatures from 40 to 500 oC, in vacuum up to 1x10−3 mmHg, or in an inert gas of high purity. They are used for drying, light annealing, aging, low and medium tempering in an oxidizing environment, degassing of ferrous and non-ferrous metals (including copper and copper alloys), or any other materials processed under similar conditions. The program setting of heat treatment modes including vacuuming, high purity inert gas intake with repeated vacuuming allows heating in an oxidizing environment with high purity of the surfaces of the processed parts, without scale formation and oxidation.
Produced in: Tula
CF Rotating Flanges
CF Rotating Flanges
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
Produced in: Kazan
Vacuum drying cabinet with manual control SNVS-50/3.5
Vacuum drying cabinet with manual control SNVS-50/3.5
from 340 671 ₽
The SNVS-50/3.5 vacuum drying cabinet with a volume of 50 liters with manual vacuum adjustment is designed for heat treatment of materials at temperatures up to 350 with air access and in a vacuum controlled by manual valves. Thanks to modern temperature control, it demonstrates excellent performance of heat treatment modes. The measurement system complies with Russian standards and has certificates of entry into the SI State Register. Design for heat treatment in production and clean laboratories. The cabinet can be equipped with a software control device with an automatic timer and a wide selection of additional options.
Produced in: Tula
Flanges for welding
Flanges for welding
Size of DN: 40 to 160.
Produced in: Kazan
Vacuum diaphragm pump PL.HM02.02.6 - Primelab
Vacuum diaphragm pump PL.HM02.02.6 - Primelab
from 215 000 ₽
Has a number of advantages: High chemical resistance; Excellent quality. The chambers are made of fluoroplastic, all elements are coated with fluoroplastic, and the valves are made of FFKM; Low noise level (up to 75 dBA); Different ways to connect cameras with the ability to change technical characteristics; Compact dimensions; Ease of use. Characteristics Valve(s) material FFKM (Perfluoro rubber) Working medium Gas Country Russia Chemical resistance Yes Overall dimensions, L×W×H, mm 321.5x140x200 Protection class acc. to DIN EN60529 IP20 Noise level, dB 75 dB Power supply 230 V, 50 Hz Ultimate vacuum, mbar abs. 6/ 45/ 45 (serial/parallel/independent connection) Excess pressure, bar. Max. permissible 0.5 bar Capacity, l/min 38/ 76/ 38x2 (series/parallel/independent connection) Drive rotation speed, rpm 1350 Maximum current, A 1.2 Device weight, kg 9 Working chamber material PTFE (polytetrafluoroethylene) Equipment: Vacuum pump, cable, instructions, passport, packaging (vacuum regulator and spare parts are not included in the kit and must be ordered separately).
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
ZVpP-100 Pneumatic Vacuum Shutter
ZVpP-100 Pneumatic Vacuum Shutter
The ZVpP-100 vacuum valve with pneumatic actuator equipped with 100mm conditional passages is designed to overlap vacuum systems in the pressure range from 1x10-6 to 1,07x105 Pa (from 0,75x10-8 to 800 mm Hg). The ZVpP-100 vacuum pneumatic shutter is manufactured in the climatic version of the UHL placement category 4 (i.e. for moderate and cold climate) according to GOST standard 15150-69. The working environment is air and non–aggressive gases. The temperature of the working environment is from plus 1°C to plus 40°C. The vacuum valve with a pneumatic actuator is not intended for use in fire and explosive hazardous industries. The ZVpP-100 vacuum pneumatic shutter consists of a mechanism, a housing and a pneumatic actuator. The pneumatic actuator includes a pneumatic cylinder, on the piston of which a permanent magnet is installed to determine its position by means of magnetic position sensors "Closed" and "Open" fixed on the cylinder body and a distributor into which compressed air is supplied through a fitting. The speed of the pneumatic cylinder in particular and the operation of the shutter as a whole are regulated by rotating the pneumatic throttle head, if the pneumatic throttle heads are fully tightened, then the speed of opening and closing the shutter will be maximum. The solenoid, powered by a connector, serves as a distributor control device and is applicable in standard production conditions where the relative humidity of the air is not higher than 75%.
Produced in: Kazan
2ZVE-250R Electromechanical vacuum shutter with gearbox
2ZVE-250R Electromechanical vacuum shutter with gearbox
The 2ZVE-250R vacuum shutter with electromechanical drive equipped with 250mm conditional passages is designed to overlap vacuum systems in the range of operating pressures from 1x10-6 to 1.07x105 Pa (0.75x10–8 to 800 mm Hg). The 2ZVE-250R shutter is pendulum-type. The 23VE-250R shutter is manufactured in the climatic version UHL (i.e. for moderate and cold climate) and O (i.e. general) 4 according to GOST standard 15150-69. The working environment is air and non–aggressive gases. It is not intended for use in fire and explosive hazardous industries. The 23VE-250R shutter meets the requirements of technical specifications TU 3648-040-00218526-2003. According to the method of protecting a person from electric shock, the gate belongs to Class I electrical equipment according to GOST 12.2.007.0-75.
Produced in: Kazan
ND-1000 High vacuum diffusion pump
ND-1000 High vacuum diffusion pump
The working condition of the ND-1000 diffusion pump depends on the temperature of the working fluid in the pump boiler. During the initial filling, it is recommended to fill the maximum volume of the working fluid. The working fluid is "VACMA OIL 500" vacuum oil (under technical specifications TU 19.20.29-061-00218526-2019). The total amount of working fluid in the ND-1000 diffusion pump is a maximum of 23 liters, a minimum of 16 liters. The viewing window for visual inspection of the working fluid has marks of its maximum and minimum amounts. During normal operation of the pump, the level of the working fluid practically does not change. The temperature of the working fluid when the pump is operating at the maximum residual pressure is about 240°C to 255°C. It is recommended to monitor the operation of heaters in the ND-1000 diffusion pump using two temperature sensors. The temperature sensor must be installed in a special radiator socket above the heater. In the event that there is a loss of working fluid and an increase in the temperature of the radiators to 360 0C for the ND-1000 diffusion pump, the temperature sensor must give the command to automatically turn off the heaters. The subsequent activation of the pump heaters should not be automatic and should be performed only after cooling the system. Water at the inlet to the cooling systems of the housing and the oil reflector must be supplied with a pressure of 0.3 MPa (3 kgf/cm2) to 0.5 MPa (5 kgf/cm2) and a temperature of plus 4°C to plus 25°C. The recommended cooling water consumption for the housing is 1500 l/h, for the oil reflector 150 l / h and is regulated by the outlet water temperature, which should not exceed plus 40°C. The water drain should be free (with a jet break).
Produced in: Kazan
Vacuum drying cabinet with manual control SNVS-215/5
Vacuum drying cabinet with manual control SNVS-215/5
from 966 298 ₽
The SNVS-215/5 vacuum drying cabinet with a volume of 215 liters with manual vacuum adjustment is designed for heat treatment of materials at temperatures up to 500 with air access and in a vacuum controlled by manual valves. Thanks to modern temperature control, it demonstrates excellent performance of heat treatment modes. The measurement system complies with Russian standards and has certificates of entry into the SI State Register. Design for heat treatment in production and clean laboratories. The cabinet can be equipped with a software control device with an automatic timer and a wide selection of additional options.
Produced in: Tula