Vacuum cooling trap FVC-12/20
Vacuum cooling trap FVC-12/20
from 432 432 ₽
The vacuum condenser type trap with a capacity of 12 liters is designed to condense vapors of non-aggressive gases on the internal cooled surfaces of the trap, in order to prevent them from entering the pump.
Produced in: Tula
ZVPlE-500 Flat Electric Vacuum Shutter
ZVPlE-500 Flat Electric Vacuum Shutter
The ZVPlE-500 shutter consists of a housing with connecting flanges, a shutter mechanism, a lip seal to ensure the tightness of the drive element, cover, and electric drive. The shutter mechanism consists of a carriage, an upper and lower flap, which are pulled together by springs and balls. The carriage moves along the housing guides on bearings. The ZVPlE-500 shutter is opened and closed both by electric drive and manually using a flywheel. To switch to manual control mode, there is a switching device on the electric drive. The manual drive is used to adjust and regulate the shutter. ZVPlE-500 valves are manufactured in climatic versions UHL (i.e. for moderate and cold climate) and O (i.e. general) 4 according to GOST standard 15150-69.
Produced in: Kazan
Tees
Tees
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
Produced in: Kazan
Vacuum drying cabinet with automatic adjustment SNVS-25/3,5
Vacuum drying cabinet with automatic adjustment SNVS-25/3,5
from 662 607 ₽
The series is designed for heat treatment according to pre-created programs. The presence of remote control and a number of software options allows you to use the product for long-term heat treatment modes. Vacuum drying cabinets can be used for: - gentle drying of thermo- and oxygen-sensitive substances, such as food, medicinal, cosmetic products; - complete removal of residual moisture from heat-sensitive components with a complex shape, such as components of electronic equipment, jewelry, watches and other precision mechanics; - removal of air when filling the molds with a compound, followed by solidification at a given temperature; - removing air from the product and replacing it with another necessary gas medium; - tempering, annealing or aging of metals with the appropriate processing temperature in a vacuum or protective environment; - drying of products after washing in flammable solvents (special version); - testing of devices under low pressure conditions under various temperature conditions.
Produced in: Tula
Centering rings (stainless steel) with a metal-ceramic filter (stainless steel) and O-ring of circular cross-section
Centering rings (stainless steel) with a metal-ceramic filter (stainless steel) and O-ring of circular cross-section
The ISO-KF connection (DIN 28 403 and ISO 2861) allows quick installation and replacement of components in vacuum systems. The connection consists of two symmetrical ISO-KF flanges (1), a centering ring with an O-ring seal (2) and a quick-release clamp (3). High-vacuum ISO-KF connections can be mounted without using a tool by simply turning the nut of the quick-release clamp.
Produced in: Kazan
LI-500 Integrated Vacuum Trap
LI-500 Integrated Vacuum Trap
The integrated flanged trap LI-500 is installed inside the diffusion pump instead of the standard oil reflector, without increasing the overall dimensions of the diffusion pump. The LI-500 trap performs the function of an oil reflector, is installed instead of a standard oil reflector in pumps, has an additional number of cooled screens for capturing oil return flow vapors (more than that of the MU trap), covers the entire area of the input high-vacuum flange.
Produced in: Kazan
LA-100 Nitrogen Vacuum Trap
LA-100 Nitrogen Vacuum Trap
The LA-100 nitrogen filler trap is installed on the inlet flange of the diffusion pump and is designed to reduce the flow of working fluid vapors into the pumped volume by condensing them on the elements of the freezing device cooled with liquid nitrogen.
Produced in: Kazan
Electric resistance chamber vacuum furnace SNVS-1.5.2.0/10SHM10
Electric resistance chamber vacuum furnace SNVS-1.5.2.0/10SHM10
The electric furnace SNVS-1,5.2,0/10SHM10 is designed for heat treatment in vacuum, according to the technological process. The execution Of The Electric Furnace is mine. The type of cage is monoblock or composite. The loading direction is vertical. The loading method is by universal shop lifting mechanisms.
Produced in: Tula
ND-630 High-vacuum diffusion pump
ND-630 High-vacuum diffusion pump
The working condition of the ND-630 diffusion pump depends on the temperature of the working fluid in the pump boiler. During the initial filling, it is recommended to fill the maximum volume of the working fluid. Working fluid is "VACMA OIL 500" vacuum oil (uner technical specifications TU 19.20.29-061-00218526-2019). The total amount of working fluid in the ND-630 diffusion pump is a maximum of 9 liters, a minimum of 6 liters. The viewing window for visual inspection of the working fluid has marks of its maximum and minimum amounts. During normal operation of the pump, the level of the working fluid practically does not change. The temperature of the working fluid when the pump is operating at the maximum residual pressure is about 240°C to 255°C. It is recommended to monitor the operation of heaters in the ND-630 diffusion pump using one temperature sensor. The temperature sensor must be installed in a special radiator socket above the heater. If there is a loss of working fluid and an increase in the temperature of the radiators of the ND-630 diffusion pump up to 360°C, the temperature sensor must give the command to automatically turn off the heaters. The subsequent activation of the pump heaters should not be automatic and should be performed only after cooling the system. Water at the inlet to the cooling systems of the housing and the oil reflector must be supplied with a pressure of 0.3 MPa (3 kgf/cm2) to 0.5 MPa (5 kgf/cm2) and a temperature of plus 4°C to plus 25°C. The recommended cooling water consumption for the housing is 600 l/h, for the oil reflector it is 80 l / h. It is regulated by the outlet water temperature, which should not exceed plus 40°C. The water drain should be free (with a jet break).
Produced in: Kazan
Electric cabinet vacuum drying SHSV-65/7-I2PV
Electric cabinet vacuum drying SHSV-65/7-I2PV
The vacuum drying cabinet SHSV-65/7-I2PV is designed for drying and heating various materials in air and in vacuum at temperatures up to 700 ° C.