Crimp support rings (stainless steel) for sealing rings with high sealing capacity
Crimp support rings (stainless steel) for sealing rings with high sealing capacity
The ISO-KF connection (DIN 28 403 and ISO 2861) allows quick installation and replacement of components in vacuum systems. The connection consists of two symmetrical ISO-KF flanges (1), a centering ring with an O-ring seal (2) and a quick-release clamp (3). High-vacuum ISO-KF connections can be mounted without using a tool by simply turning the nut of the quick-release clamp.
Produced in: Kazan
Explosion-proof vacuum electric furnace START-65
Explosion-proof vacuum electric furnace START-65
Vacuum resistance furnaces are necessary for heating products before pressure treatment, for sintering, degassing, quenching, annealing, soldering and chemical-technological processes. Such furnaces among all the variety of thermal equipment are considered the most environmentally friendly – heat treatment is carried out at t up to +2500 ° C in a purified vacuum. Under certain conditions, vacuum furnaces are used to work with neutral gases. The outer part of the furnace is made of stainless steel and is cooled by liquid. The inner part of the working chamber, where the heat treatment of materials is carried out, is made of an alloy of molybdenum and tungsten. The components are characterized by a low inertia force, reduced gas separation. The settings are available on the control panel, where the instruments, automatic and manual control switches are located. At every enterprise of the electronic industry, nuclear power, an explosion-proof vacuum resistance furnace is needed. The same applies to areas where various products undergo heat treatment at the stage of production and preparation for use.
Produced in: Tula
2ZVE-100 Electromechanical Vacuum shutter
2ZVE-100 Electromechanical Vacuum shutter
The 2ZVE-100 vacuum shutter with electromechanical drive equipped with conditional passages of 100 mm is designed to overlap vacuum systems in the range of operating pressures from 1x10-6 to 1.07x105 Pa (0.75 x10–8 to 800 mm Hg). Type of shutter 2ZVE-100 pendulum. The 23VE-100 shutter is manufactured in the climatic version of UHL (i.e. for moderate and cold climate) and O (i.e. general) 4 according to GOST 15150-69. The working environment is air and non–aggressive gases and. It is not intended for use in fire and explosive hazardous industries. The 23VE-100 shutter meets the requirements of technical specifications TU 3648-040-00218526-2003. According to the method of protecting a person from electric shock, the gate belongs to Class I electrical equipment according to GOST 12.2.007.0-75.
Produced in: Kazan
Electric cabinet vacuum drying SHSV-3,5.3,5.6/2.5-I2M
Electric cabinet vacuum drying SHSV-3,5.3,5.6/2.5-I2M
The vacuum drying cabinet SHSV-3,5.3,5.6/2.5-I2M is designed for drying and heating various materials in air and in vacuum at temperatures up to 250 ° C., including in the range of I.K. radiation, with a wavelength of 1,2 – 3,8 microns.
Produced in: Tula
SNVS Vacuum Furnace-3.3/15- I6
SNVS Vacuum Furnace-3.3/15- I6
High-temperature furnaces are capable of heating materials up to 1700 degrees. The scope of their application covers the heat treatment of various materials in an inert medium or vacuum. TULA-TERM furnaces are used for heat treatment of plastics, ceramics, metals, alloys, lacquers and other materials. The equipment allows sintering, annealing, soldering, quenching, drying, burning and molding. In industry, our installations are most often used for quenching parts and sintering hard alloys.
Produced in: Tula
Spare ring gaskets for flanges
Spare ring gaskets for flanges
The ISO-KF connection (DIN 28 403 and ISO 2861) allows quick installation and replacement of components in vacuum systems. The connection consists of two symmetrical ISO-KF flanges (1), a centering ring with an O-ring seal (2) and a quick-release clamp (3). High-vacuum ISO-KF connections can be mounted without using a tool by simply turning the nut of the quick-release clamp. The dimensions of the DN are 10,16,20,25,32,40,50.
Produced in: Kazan
ND-400 High-vacuum Diffusion pump
ND-400 High-vacuum Diffusion pump
The working condition of the ND-400(R) diffusion pump depends on the temperature of the working fluid in the pump boiler. During the initial filling, it is recommended to fill the maximum volume of the working fluid. Working fluid is "VACMA OIL 500" vacuum oil (under technical specifications TU 19.20.29-061-00218526-2019). The total amount of working fluid in the ND-400(R) diffusion pump is a maximum of 5 liters, a minimum of 3.3 liters. The viewing window for visual inspection of the working fluid has marks of its maximum and minimum amounts. During normal operation of the pump, the level of the working fluid practically does not change. The temperature of the working fluid when the pump is operating at the maximum residual pressure is about 240°C to 255°C. It is recommended to monitor the operation of heaters in the ND-400(R) diffusion pump using one temperature sensor. The temperature sensor must be installed in a special radiator socket above the heater. If there is a loss of working fluid and an increase in the temperature of the radiators of the ND-400(P) diffusion pump to 320°C, the temperature sensor must give the command to automatically turn off the heaters. The subsequent activation of the pump heaters should not be automatic and should be performed only after cooling the system. Water at the inlet to the cooling systems of the housing and the oil reflector must be supplied with a pressure of 0.3 MPa (3 kgf/cm2) to 0.5 MPa (5 kgf/cm2) and a temperature of plus 4°C to plus 25°C. The recommended cooling water consumption for the housing is 250 l/h, for the oil reflector it is 40 l / h. It is regulated by the outlet water temperature, which should not exceed plus 40°C. The water drain should be free (with a jet break).
Produced in: Kazan
Electric cabinet vacuum drying SHSV-3,5.3,5.6/2.5-S
Electric cabinet vacuum drying SHSV-3,5.3,5.6/2.5-S
This electric vacuum drying cabinet is designed for drying and heating various materials in air and in vacuum at temperatures up to 250 ° C. A viewing window Ø 160 mm is installed in the door. The illumination of the working chamber is provided from the outside. An additional, independent security system is installed in the cabinet, interrupting the supply of the cabinet when operating temperatures exceed.
Produced in: Tula
Vacuum drying cabinet SNVS-40/5
Vacuum drying cabinet SNVS-40/5
They are designed for carrying out various technological processes at temperatures from 40 to 500 oC, in vacuum up to 1x10−3 mmHg, or in an inert gas of high purity. They are used for drying, light annealing, aging, low and medium tempering in an oxidizing environment, degassing of ferrous and non-ferrous metals (including copper and copper alloys), or any other materials processed under similar conditions. The program setting of heat treatment modes including vacuuming, high purity inert gas intake with repeated vacuuming allows heating in an oxidizing environment with high purity of the surfaces of the processed parts, without scale formation and oxidation.
Produced in: Tula
2NVBM-630/18000 Booster high vacuum pump
2NVBM-630/18000 Booster high vacuum pump
The 2NVBM-630(R)/18000 pump is designed for pumping out of sealed volumes of air, gases, vapors and vapor-gas mixtures that are non-aggressive to the materials of the structure and the working fluid of the pump in the range of inlet pressures from 13.3 to 6.6x10-2 Pa (from 1x10-1 to 5x10-4 mmHg.) and do not contain droplet moisture and mechanical impurities. The 2NVBM-630(R)/18000 pump is used in conjunction with pre-vacuum pumps as part of technological installations or systems in stationary conditions. The type of climatic version of UHL4 and O4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, but it is intended for operation at ambient temperature from plus 10°C to plus 35°C for UHL4 and from plus 10°C to plus 45°C for O4, at cooling water temperature from plus 10°C to plus 20°C. The 2NVBM-630(R)/18000 pump is not intended for use in fire dangerous and explosive industries.
Produced in: Kazan
50M URS special manual vacuum angle valve
50M URS special manual vacuum angle valve
The body of the 50M URS valve is of welded construction and consists of a shell, a seat, side and lower nozzles. The lower branch pipe of the 50M URS valve is connected to the vacuum system using welding. The smooth part of the stem serves as a visual indicator of the "open" or “closed” valve positions. The casing is designed to protect the valve from accidental openings, and also serves as additional protection against precipitation, sand, dust entering the inner cavity of the valve. The valve opens when the flywheel rotates counterclockwise. The valve closes when the flywheel rotates clockwise.
Produced in: Kazan
Vacuum drying cabinet with automatic adjustment SNVS-50/5
Vacuum drying cabinet with automatic adjustment SNVS-50/5
The series is designed for heat treatment according to pre-created programs. The presence of remote control and a number of software options allows you to use the product for long-term heat treatment modes. Vacuum drying cabinets can be used for: - gentle drying of thermo- and oxygen-sensitive substances, such as food, medicinal, cosmetic products; - complete removal of residual moisture from heat-sensitive components with a complex shape, such as components of electronic equipment, jewelry, watches and other precision mechanics; - removal of air when filling the molds with a compound, followed by solidification at a given temperature; - removing air from the product and replacing it with another necessary gas medium; - tempering, annealing or aging of metals with the appropriate processing temperature in a vacuum or protective environment; - drying of products after washing in flammable solvents (special version); - testing of devices under low pressure conditions under various temperature conditions.
Produced in: Tula