Search

112 products
View:
  • Selected: 0
    Areas of use
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 1
    Additional
All filters
  • 10
    Areas of use
  • 22
    Item names
    Loading...
  • 6
    Manufacturer
  • 9
    Made in
  • Additional
View:
112 products
Blocks of processing and transmission of information BOP-1sp
Blocks of processing and transmission of information BOP-1sp
Purpose: processing of information received from detection units (primary converters); data transmission to the information network; data transfer to a portable computer (remote control tuning PN-PC); storage of threshold settings and parameters of detection units (primary converters); power supply and diagnostics of detection units (primary converters); output of threshold exceeding signals to built-in sound and LED alarms and to remote alarm units (BAS/BAS-1c); output of discrete signals (dry contacts); archiving of data in non-volatile memory.
Doza
Zelenograd
Produced in: Moscow
SPECTROMETRIC RADIATION MONITORING SYSTEM
SPECTROMETRIC RADIATION MONITORING SYSTEM
Displaying the spectra and dose rates measured by each detection unit (DB) on the object plan or terrain map Identification of the radionuclide composition of the source The possibility of expanding the energy range up to 5 MeV Sealed DB design (IP68) Backup power supply
Produced in: Belarus, Minsk
RADIOACTIVITY INDICATOR IR‑AT2522 (ALPHA SENSOR)
RADIOACTIVITY INDICATOR IR‑AT2522 (ALPHA SENSOR)
Rapid assessment of surface contamination with alpha-active radionuclides, in particular, polonium-210. The device is easy to operate, suitable for use by personnel of any qualification, including at home. ▪ Scintillation detector ▪ Silicon photoelectronic multiplier ▪ High sensitivity ▪ Light and sound indication when registering alpha particles ▪ Long-term operation without recharging ▪ 1" OLED colour screen
Produced in: Belarus, Minsk
DOSIMETER‑RADIOMETER MKS‑AT1117M (WITH HERMETIC CONTAINERS FOR DETECTION UNITS)
DOSIMETER‑RADIOMETER MKS‑AT1117M (WITH HERMETIC CONTAINERS FOR DETECTION UNITS)
Measurement of the ambient dose equivalent or absorbed dose rate of gamma radiation in liquid media, wells, underground storage facilities and other hard-to-reach places Compatible with detection units: BDKG-01, BDKG-03, BDKG-04, BDKG-05, BDKG-17, BDKG-24, BDKG-30 Measurement at depths up to 30 meters Marking on the cable to determine the depth of immersion A Cable Winding Coil
Produced in: Belarus, Minsk
Atom Fast 8816 - radiation dosimeter on a scintillator for a smartphone
Atom Fast 8816 - radiation dosimeter on a scintillator for a smartphone
from 29 500 ₽
1 supp.
Overall dimensions of the device (mm) 113*25*14 The service life of the built-in battery is at least 300 cycles within the warranty period of the device Full charge time The time to fully charge the built-in battery from a PC USB port or charger is no more than 4 hours. Operating time from a fully charged built-in battery under natural radiation conditions without the use of wireless communication and sound/vibration alarms is at least 4 months Maximum counting speed (imp/sec) is not less than 10,000 imp/s (600,000 imp/min). Device weight (g) no more than 50
Note Atom Fast can withstand irradiation with a dose rate of up to 2000 R/h for 2 s without damage and fully restores functionality after cessation of irradiation in no more than 2 s. Operating temperature range from -40 to +40 degrees. C (for the “new” detection block edition from the fall of 2019, the range is from -20 to +40). When the temperature rises above +40 degrees. C, the device will warn the user about this with the sound of a two-tone siren repeating once a minute. With a further increase in temperature, correct operation of the device is not guaranteed. Energy range of detected photon radiation (keV) Working size of scintillation detector (mm) 8*8*16

Contents of delivery USB cable for charging the built-in lithium-ion battery 1 pc. Dosimeter attachment Atom Fast 8816 - 1 pc. Packing box 1 pc. Carrying case - 1 pc.
Produced in: Moscow, Troitsk
X‑RAY CALIBRATION INSTALLATIONS UPR‑AT300, UPR‑AT300/1, UPR-AT300/2
X‑RAY CALIBRATION INSTALLATIONS UPR‑AT300, UPR‑AT300/1, UPR-AT300/2
Storage and transfer of kerma units in the air, ambient, individual and directional dose equivalents and their X-ray radiation capacities to working standards and measuring instruments. ▪ The use of highly stable ISOVOLT X-ray machines with metal-ceramic tubes ▪ Field shaper with radiation qualities according to GOST 8.087, ISO 4037, IEC 61267, etc. ▪ Replaceable discs with 11 filter slots; 3 replaceable diaphragms ▪ Additional filters up to 50 mm thick ▪ A protective flap made of tungsten with beam attenuation of more than 1000 times and a response time of less than 0.1 s ▪ A camera monitor and an electrometric unit provide monitoring of the presence and stability of the radiation output ▪ A positioning system in the radiation beam along three axes ▪ A laser detector centering devices ▪ A video surveillance system of indications ▪ Alarm and blocking systems, radiation monitoring ▪ A control system using operator panels and PC
Produced in: Belarus, Minsk
RADIATION PEDESTRIAN MONITORS MPP‑AT920V, MPP‑AT920R (SRK‑AT2327)
RADIATION PEDESTRIAN MONITORS MPP‑AT920V, MPP‑AT920R (SRK‑AT2327)
Rapid adaptation to changes in the radiation background Audible and light alarms The possibility to create a network of MCI (up to 32) under the control of a PC and specialized software Mobility and the possibility to organize the control of passages in a short time High reliability and self-control Backup power supply
Produced in: Belarus, Minsk
RADIOMETER RKS‑AT1329
RADIOMETER RKS‑AT1329
The radiometer allows you to: - measure the total alpha and total beta activity of counting samples based on aerosol analytical filters of the AFA type; - measure the total alpha and total beta activity of "thick-layer" counting samples prepared from the sample substance (for example, by evaporation or by any other method that provides a "thick" sample); - measure the total alpha and total beta activity of "thin-layer" counting samples prepared from the sample substance (for example, by electrolytic deposition); - measure activity, flux density, external alpha and beta radiation for sources of type 1P9, 2P9, 3P9, 1C0, 2C0, 3C0; - control radiation contamination of surfaces by smears. Device control and measurement data processing is performed by an external PC The possibility to use custom calibrations The possibility to select units of measurement LED stabilization of the measuring path Passive lead protection against background radiation The possibility to maintain a measurement database Methodological support of measurements
Produced in: Belarus, Minsk
DOSIMETERS‑RADIOMETERS ISS‑AT6130, ISS‑AT6130A, ISS‑AT6130D
DOSIMETERS‑RADIOMETERS ISS‑AT6130, ISS‑AT6130A, ISS‑AT6130D
Small-sized devices for measuring the power of the ambient dose equivalent and the ambient dose equivalent of X-ray and gamma radiation, as well as measuring the flux density of beta particles (AT6130). Durable metal case Convenient menu Selective measurement of beta and gamma radiation in mixed fields (AT6130) Measurement of dose rate up to 100 mSv/h (AT6130D) Search mode Headphones for working in noisy environments (on request)
Produced in: Belarus, Minsk
Installation of control of surface radioactive contamination of personnel RZA-08D
Installation of control of surface radioactive contamination of personnel RZA-08D
Installation for monitoring radioactive contamination of hands, feet (shoes) and clothing of personnel with alpha- and beta - active substances. Modern and intuitive interface, various versions. Purpose: monitoring the level of contamination of hands, feet (shoes) and clothing of personnel with alpha- and beta-active substances and signaling when exceeding permissible levels; measurement of alpha and beta radiation flux density from the surface of the hands, feet (shoes) and clothing of personnel; measurement of the surface activity of alpha- and beta-emitting radionuclides of hands, feet (shoes) and clothing of personnel.
Doza
Zelenograd
Produced in: Moscow
RADIATION TRANSPORT MONITORS (SRK‑AT2327)
RADIATION TRANSPORT MONITORS (SRK‑AT2327)
Modular principle of system construction Automatic correction of threshold levels when the background level of the environment changes High reliability and self-control Backup power supply Automatic data logging The possibility of connecting a video surveillance system
Produced in: Belarus, Minsk
DOSIMETER‑RADIOMETER MKS‑AT1117M WITH DETECTION UNIT BDKN‑06 AND A SET OF RETARDER SPHERES
DOSIMETER‑RADIOMETER MKS‑AT1117M WITH DETECTION UNIT BDKN‑06 AND A SET OF RETARDER SPHERES
The result of determining the energy distribution of the neutron radiation flux density is used to calculate such quantities as: - integral neutron flux density; - the average energy of neutron radiation in the spectrum; - the average neutron radiation energy by dose; - dose equivalent per unit flow density; - dose equivalent; - effective dose. ▪ Methodological support of measurements ▪ It is possible to supply an expanded set of polyethylene retarder spheres with diameters: 3,5”; 4,5”; 5”; 7”; 9”; 9,5”
Produced in: Belarus, Minsk