Search

112 products
View:
  • Selected: 0
    Areas of use
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 1
    Additional
All filters
  • 10
    Areas of use
  • 22
    Item names
    Loading...
  • 6
    Manufacturer
  • 9
    Made in
  • Additional
View:
112 products
Dosimetric thermoluminescent complex "DOSE-TLD"
Dosimetric thermoluminescent complex "DOSE-TLD"
Purpose: measurement of the individual dose equivalent of Hp(10) photon radiation; measurement of the individual dose equivalent of Hp(10) neutron radiation; measurement of the individual dose equivalent in the skin Hp(0.07) and the lens of the eye Hp(3) of photon and beta radiation; measurement of ambient dose equivalent H*(10) of photon radiation.
Doza
Zelenograd
Produced in: Moscow
DOSIMETRIC INSTALLATION OF GAMMA RADIATION UDG‑AT110
DOSIMETRIC INSTALLATION OF GAMMA RADIATION UDG‑AT110
Irradiator with a typical collimator Rotary drum magazine sources in tungsten and lead protection Software control of the movement of sources and positioning of the mobile platform An alarm and blocking system, radiation monitoring system to ensure the safety of the installation Control from the operator panel or computer with verification automation functions
Produced in: Belarus, Minsk
SPECTROMETERS MKS‑AT6104DM, MKS‑AT6104DM1
SPECTROMETERS MKS‑AT6104DM, MKS‑AT6104DM1
Determination of the position of the detection device in space during measurements A cable coil with current transfer Presentation of measurement results in the form of distribution maps of the content of controlled radionuclides or the dose rate of gamma radiation Expert mode for the analysis of the instrument spectrum with automatic identification of the radionuclide composition of the sample GARM expert software for subsequent data processing and analysis, as well as radiation mapping
Produced in: Belarus, Minsk
BAS/BAS-1c Alarm Units
BAS/BAS-1c Alarm Units
Purpose: BAS: The unit is designed to provide light and sound signals under various conditions of controlled radiation conditions when connected to technical means that have a communication port with the unit (BOP, UDA-1AB, UDI-1B, UDG-1B, etc.). BAS-1c: The unit is designed to provide light and sound signals under various conditions of a controlled radiation environment, and operates under the control of an external device. The unit can be used in connection with individual technical means of radiation monitoring or as part of radiation monitoring systems and complexes, as well as with other compatible technical means that provide data exchange over communication lines organized on the basis of the RS-485 interface, using the DiBus exchange protocol (BOP-1M).
Doza
Zelenograd
Produced in: Moscow
Installation radiometric UDI-1B
Installation radiometric UDI-1B
Installation for continuous automatic monitoring of the concentration of iodine radionuclides in an autonomous mode or as part of automatic radiation monitoring systems in the air of working rooms and ventilation systems. Purpose: measurement of volumetric activities of iodine radionuclides I-131, I-132, I-133 and I-135 in the air.
Doza
Zelenograd
Produced in: Moscow
DOSIMETERS‑RADIOMETERS ISS‑AT1125, ISS‑AT1125A
DOSIMETERS‑RADIOMETERS ISS‑AT1125, ISS‑AT1125A
- Measurement of the dose and power of the ambient equivalent of the dose of X-ray and gamma radiation; - Control of the content of 137Cs in samples placed in a Marinelli vessel with a volume of 0.5 liters, both with and without the protection unit (BZ); - Measurement of the flux density of alpha and beta particles from contaminated surfaces (external detection unit BDPS-02); - Search and detection of X-ray and gamma radiation sources. High sensitivity Spectrum display mode when connected to a PC
Produced in: Belarus, Minsk
INDIVIDUAL DOSIMETERS DKS‑AT3509, DKS‑AT3509A, DKS‑AT3509V, DKS‑AT3509S
INDIVIDUAL DOSIMETERS DKS‑AT3509, DKS‑AT3509A, DKS‑AT3509V, DKS‑AT3509S
Control of individual radiation doses from X-ray and gamma radiation. Together with a reader connected to a PC and specialized application software, they form an effective system for automated control of dose loads on personnel. Silicon Planar Detector Lack of own background Simultaneous measurement of dose loads on internal organs Hp(10) and skin Hp (0.07)
Produced in: Belarus, Minsk
DOSIMETERS DKG‑AT2140, DKG‑AT2140A, DKG‑AT2140A/1
DOSIMETERS DKG‑AT2140, DKG‑AT2140A, DKG‑AT2140A/1
A small-sized economical device for measuring the power of the ambient dose equivalent and the ambient dose equivalent of X-ray and gamma radiation. A unique combination of economy, speed and usability Working time without replacing batteries (2 x AA): AT2140 - 5000 hours, AT2140A, A/1 - 10000 hours Search mode USB interface and software for configuring the dosimeter and viewing the measured information (AT2140A/1)
Produced in: Belarus, Minsk
Gamma radiation detector threshold stationary SRPS-05D
Gamma radiation detector threshold stationary SRPS-05D
A simple and reliable device for monitoring the radiation situation in rooms where work is carried out with radioactive sources (substances, medications, installations). If the set threshold value of the dose rate is exceeded, the device gives a sound and light signal, controls external devices (for example, door locking devices). Purpose: measurement of the ambient dose equivalent of gamma radiation (MAED); sound and light alarm about exceeding the set threshold; activation of external signaling or actuating devices.
Doza
Zelenograd
Produced in: Moscow
Installation of control of surface radioactive contamination of personnel RZBA-08D
Installation of control of surface radioactive contamination of personnel RZBA-08D
Installation for monitoring radioactive contamination of hands, feet (shoes) and clothing of personnel with beta-, gamma- and alpha-active nuclides, convenient and intuitive interface, various versions. Purpose: monitoring the level of contamination of hands, feet (shoes) and clothing of personnel with beta-, gamma- and alpha-emitting radionuclides and signaling when exceeding permissible levels; measurement of beta and alpha radiation flux density from the surface of the hands, feet (shoes) and clothing of personnel; measurement of surface activity of alpha- and beta-emitting radionuclides of hands, feet (shoes) and clothing of personnel; measurement of the ambient dose equivalent (MAED) power of gamma radiation.
Doza
Zelenograd
Produced in: Moscow
Dosimetric installations "Gamma sensor"
Dosimetric installations "Gamma sensor"
Appointment: Measurement of the ambient dose equivalent (MAED) power of gamma radiation during radiation reconnaissance and operational control of radioactive contamination of the area. Installations can be installed on cars and other mobile means, except for air.
Doza
Zelenograd
Produced in: Moscow
 INDIVIDUAL DOSIMETERS DKG‑AT2503V, DKG‑AT2503V/1, DKG‑AT2503V/2
INDIVIDUAL DOSIMETERS DKG‑AT2503V, DKG‑AT2503V/1, DKG‑AT2503V/2
Control of individual radiation doses from X-ray and gamma radiation. Together with the reader and software, they form an effective system for automated control of dose loads on personnel. ▪ Simultaneous measurement of the power of the individual dose equivalent and the dose of gamma radiation ▪ Automatic compensation of the detector's own background ▪ The mode of signaling the presence of pulsed radiation with a duration of 10 ns (optional)
Produced in: Belarus, Minsk