Search

17 products
View:
  • Selected: 0
    Applying
  • Selected: 0
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 1
    Additional
    Loading...
All filters
  • 11
    Applying
  • 14
    Names
  • 5
    Manufacturer
  • 5
    Made in
  • Additional
    Loading...
View:
17 products
Raid bomb BR-02T
Raid bomb BR-02T
It is designed to determine the absolute vapor pressure of crude oil and petroleum products with a saturated vapor pressure over 180 kPa (except for liquefied petroleum gases) in accordance with the State Standard 1756 and the State Standard 31874 (except for method B). The ratio of volumes of air and liquid chambers within 3.95 4.05.
Produced in: Tomsk
The FLUORAT®-411 alarm is heated, with a built-in sample preparation system
The FLUORAT®-411 alarm is heated, with a built-in sample preparation system
1 supp.
Technical specifications: The power consumption of the alarm is not more than 150 watts The output electrical signal goes directly from the cable entry (B6), according to the standard scheme (4-20ma and (or) RS 485) Sample temperature is not more than 200 degrees C Sample pressure is not more than 1.5 Atm The pressure of the spent sample is not more than 0.5 Atm Cooling water temperature 5-30 Deg C Dimensions of the alarm (mm) 1200*600*400 The boundaries of the spectral range of optical radiation used for analysis, nm 240 - 380 Analysis time, from 1 Power supply - alternating voltage (220 ± 10%) V, (50± 2.5) Hz operating mode settings, min no more than 30 Display range , mg/l 0.01-30 The limit of the basic error for the trigger threshold (%) 20 The set threshold for triggering the alarm 0.1 – 30.9 in increments of 0.1 mg/l the probability of trouble-free operation during 5000 hours is not less than 0.95 average recovery time, no more than 2 hours average service life, at least 5 years
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
NEVA-412 alarm system
NEVA-412 alarm system
1 supp.
Technical specifications: Analog output 0-0.5 V (4-20 mA on request) Overall dimensions 320x255x175 mm Water pressure 0.1-3 atm The door of the alarm opens to the left side Measuring range 0-30 ppm Alarm relay contacts dry contact (power up to 2A/250V) Control relay contacts dry contact (power up to 2A/250V) Linearity +(-)2% in the range of 1-20 ppm Trigger threshold setting from 1 to 30 ppm (in increments of 1 ppm) Connecting dimensions of flanges external thread 1/2" Signal norm green LED Alarm red LED Degree of protection IP X4 The temperature of the controlled environment is +4 ... +55 °C Ambient temperature 0 ... +55 °C Measurement accuracy in accordance with resolution MERS.107(49) CF type flash memory card (software included) at least 32 MB RS485 digital output (on request) Power supply 200/240 V, 50/60 Hz (on request = 24 V) Weight not more than 10.5 kg Power consumption < 6 W
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Analyzer of petroleum products in water "FLUORATE® AE-2"
Analyzer of petroleum products in water "FLUORATE® AE-2"
1 supp.
Technical specifications: The range of detectable concentrations 0.025-1.0 and 0.1- 10 mg/l from 10 to 100 mg/l –can be used as an alarm The temperature of the analyzed flow is from + 4 to + 50 °C The pressure in the flow is 0.1-10 atm. Number of measurements per hour 1-4 Output of results Digital scoreboard, RS485, RS232, 4-20 mA current loop Display modes NORM, ALARM, LIMIT Version B1, P1, N1 according to GOST 12997-84 Category of climatic performance UHL4 according to GOST 15150-69 Ambient temperature from + 5 to + 50 °C Relative humidity at + 25 °C 80% Atmospheric pressure 84-106.7 kPa The amplitude of external vibrations with a frequency of 10-55 Hz is not more than 0.15 mm Power supply 187-242 V, 50 ± 1 Hz from an autonomous source, 12 V Power consumption not more than 100 watts Dimensions 600x600x250 mm Weight 50 kg The warranty period of operation is 1 year Average service life of at least 5 years Average time to failure of at least 20,000 hours
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Optical recorder of oil films "CRAB-1"
Optical recorder of oil films "CRAB-1"
1 supp.
Technical specifications: Sensitivity (minimum thickness of recorded oil films) from 0.5 microns The root-mean-square slope of the water surface up to 20 ° Distance from the receiving device up to 1000 m Sensor power supply 100-240 V, 50-60 Hz Power consumption up to 3 watts Ambient air temperature from -10 to +50 °C Humidity up to 100% (rain) Distance to the water surface 0.5–20 m Dimensions 120x180x120 mm Weight up to 1.5 kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg