Search

49 products
View:
  • Selected: 0
    Applying
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 1
    Additional
All filters
  • 7
    Applying
  • 17
    Names
    Loading...
  • 4
    Manufacturer
  • 4
    Made in
  • Additional
View:
49 products
Stand for measuring the electrification of tissues (to the device ST-01)
Stand for measuring the electrification of tissues (to the device ST-01)
from 17 200 ₽
Method of measuring the electrostatic field strength", SanPiN 2.4.7/1.1.1286-03 "Hygienic requirements for clothing for children, adolescents and adults", MOOK 4.1/4.3.1485-03 "Hygienic assessment of clothing for children, adolescents and adults". (available on a separate order).
Produced in: Moscow
Measuring antenna P6-62
Measuring antenna P6-62
1 supp.
Technical specifications: Frequency range (300-1000) MHz SWR < 2 The limit of permissible error of the antenna coefficient, not more than ± 2.0 dB Orthogonal polarization signal level -20 dB Ambient air temperature from - 50 to + 60 Relative humidity of 95 % at + 35 ° C Overall dimensions (HxWxD) 400x145x150 mm Weight 1 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Spectrum Analyzer S4-101
Spectrum Analyzer S4-101
Technical specifications: The operating frequency range of the monitored signals is from 9·103 to 3·109 Hz The analyzer has a zero band and a viewing band in the range from 100 Hz to 3 GHz Limits of permissible error of setting the viewing band ± 1 % The scan range is set from 10 ms to 3000 s in all modes except the zero band of view, and from 20 microseconds to 3000 s in the zero band of view mode The bandwidth of the RFP at the level of minus 3 dB is selected in the range from 100 Hz to 1 MHz in increments of 1, 3, 10 The squareness coefficient of the FPC at the level of minus 60 dB / minus 3 dB is not more than 5:1 The reference level setting range is from plus 30 dBm to minus 100 dBm. Installation step 1 dB Limits of the permissible basic error of setting the reference level ± 1 dB The limits of the unevenness of the amplitude-frequency response (frequency response) of the analyzer in the frequency range from 100 kHz to 3 GHz ± 1 dB Maximum allowable input power is 30 dBm (1 W) Limits of the permissible basic error of measuring the signal level due to the nonlinearity of the logarithmic scale ± 1 dB Limits of the permissible basic error of measuring the signal level due to switching of the input attenuator ± 1 dB Limits of error in measuring the signal level due to switching filters, ± 0.2 dB relative to the 1 kHz filter The average level of intrinsic noise at the FPC bandwidth of 100 Hz, the video filter band of 10 Hz and the input attenuator of 0 dB: - in the range from 100 kHz to 20 MHz minus 75 dBm - in the range from 20 MHz to 1.5 GHz minus 110 dBm - in the range from 1.5 to 3 GHz minus 105 dBm The input impedance of the analyzer is 50 ohms The voltage standing wave coefficient (VSWR) of the input with an input attenuator greater than 10 dB, no more: - 1.5 in the frequency range from 10 MHz to 2.5 GHz - 1.8 in the frequency range from 2.5 GHz to 3 GHz Diagonal screen size 21.5 cm Screen resolution 800x480 USB interface Overall dimensions – 398x220x150 mm Weight not more than 6.5 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
COMBI-01M (VE-meter (Modification AT-004), ST-01, MAS-01)
COMBI-01M (VE-meter (Modification AT-004), ST-01, MAS-01)
from 289 000 ₽
A set for measuring the levels of electrostatic and magnetic fields, the concentration of light negative and positive aeroions.
Produced in: Moscow
COMBO FACTOR (VE-meter 50Hz, VE-meter AT-004, E-meter AT-005, P3-34)
COMBO FACTOR (VE-meter 50Hz, VE-meter AT-004, E-meter AT-005, P3-34)
from 375 000 ₽
Frequency ranges: from 48 to 52 Hz, from 5 Hz to 400 kHz, from 10 kHz to 30 MHz, from 30 to 300 MHz, from 30 to 50 MHz, from 300 MHz to 18 GHz. three - coordinate antennas; large amount of built-in memory for recording measurement results; high measurement accuracy; the meter is provided with a two-year warranty and manufacturer's service support for the entire service life; wireless Bluetooth communication channel; Control unit and display of measurement results NTM-Terminal. single control unit; the ability to connect multiple meters to one control unit; ergonomic body and comfortable keyboard; high-resolution color display that provides a comfortable presentation of the results; ability to record measurement results; reference base of normative documentation. The meter is adapted to work in the control and analytical complex "NTM-EcoM". the possibility of monitoring the electromagnetic situation at the facilities; storage of measurement results in the NTM-EcoM program archive; analysis of the results obtained for compliance with current regulations; execution of the protocol of instrumental measurements
Produced in: Moscow
Measuring antenna P6-23M
Measuring antenna P6-23M
Technical specifications: Frequency range (0.85 - 17.44 GHz) Standing Wave Coefficient (SWR) < 1.7 Effective area at least in the frequency range - from 0.85 to 15 GHz > 150 cm2 - from 15 to 17.44 GHz > 110 cm2 The margin of error of the effective area in the frequency range, no more - from 0.85 to 8.5 GHz ± 20% - from 8.5 to 17.44 GHz ± 15% Orthogonal polarization signal level -25 dB The level of the side lobes, no more than -10 dB Ambient temperature -50°C - 50°C Gabbar dimensions (HxWxD) 887x351x265 mm Weight 6,8 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Educational laboratory complex KUL-1
Educational laboratory complex KUL-1
It is intended for use in higher and secondary educational institutions during laboratory workshops on training specialists in engineering and technical specialties and natural science disciplines. Technical specifications: Upost.- 0.1 mV - 500 V; Uperem.- 1 mV-300 V (40 Hz-20 kHz) Ippost. - 0.1 mkA- 2 A; Iperem. - 1.0 mkA - 2 A (40 Hz-1 kHz) Rpost. - 0.1 Ohm – 20 mOhm Generation of triangles, pilobr., "meander", sinusoid. signal in the frequency range 0.1 Hz – 1 MHz Frequency measurement in the range of 0.1 Hz – 1 MHz The form of the measured signals is sine, pulse Constant voltage: at a current of 1 A - + 5 V at a current of 0.5 A for each channel - ± 12 V Adjustable Uppost. at a current of up to 1 A - 0 – 30 V Dimensions - 170x340x380 mm Power supply – 230 V, 50 Hz, 200 VA - max. Weight – 8.0 kg
MNIPI
Minsk
Produced in: Belarus, Minsk