Search

44 products
View:
  • Selected: 0
    Applying
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 1
    Additional
All filters
  • 7
    Applying
  • 20
    Names
    Loading...
  • 3
    Manufacturer
  • 3
    Made in
  • Additional
View:
44 products
Connecting device UP-4
Connecting device UP-4
Technical specifications: Residual capacity when working with immitance meters < 1 pF Residual inductance when working with immitance meters < 0.5 µgn Residual resistance when working with immitance meters < 0.05 ohms Maximum input voltage ±60 V Distance between measuring contacts from 0 to 6 mm Length 1050 mm Weight 160 g
MNIPI
Minsk
Produced in: Belarus, Minsk
High-voltage test unit UPU-22
High-voltage test unit UPU-22
Technical specifications: Output voltage (DC and AC), 0 - 2 kV; 0 - 5 kV Built-in AC power supply, 10 - 25 A The amplitude value of the DC voltage ripple relative to the set output voltage of 5 kV at idle is not more than ± 5% Error in setting the output voltage, ± 3% Protection tripping current, 101 -- 140 mA Load current of DC and AC output voltage, not less than 1 mA The limit of measuring the resistance of the integrity of the circuit connection, 0, 01 – 0.10 ohms
MNIPI
Minsk
Produced in: Belarus, Minsk
Immitance Broadband Analyzer E7-29
Immitance Broadband Analyzer E7-29
Technical specifications: Extended frequency range 50 kHz–15 MHz The basic error is ±0.2 % The level of the measuring signal is 40 mV – 1 V s.c . Offset voltage (0 – 40) V The discreteness of the operating frequency setting is 1 Hz Graphical analysis of measured values in a given frequency range USB 2.0 interface -100 C to 400 C; humidity 90% at 300 C Dimensions, weight: 270x134x320 mm, 5 kg Power supply ~230 V, 20 VA
MNIPI
Minsk
Produced in: Belarus, Minsk
Generator G3-131
Generator G3-131
Technical specifications: Frequency range, from 2 Hz to 2 MHz Frequency setting error, ± 1 % Signal amplitude: - at a load of 600 ohms , at least 5 V at least 10 V Smooth signal attenuation, at least 20 dB Frequency instability: - in 15 minutes - for 180 minutes, no more than 0.1% no more than 0.5 % Harmonic coefficient: - in the frequency range from 10 Hz to 20 Hz - in the frequency range sv. 20 Hz to 200 kHz - in the frequency range of 200 kHz to 2 MHz, not more than 0.5% not more than 0.2% not more than 1 %
MNIPI
Minsk
Produced in: Belarus, Minsk
Functional signal generator G6-50
Functional signal generator G6-50
Technical specifications: The waveform is sinusoidal, meander, triangular, sawtooth, (straight, reverse), offset, rectangular (TTL) Frequency range from 0.1 Hz to 2 MHz Frequency setting error ±0.05% Frequency instability ±0.02% in 15 min The amplitude of the signal is sinusoidal ± 5 V at a load of 600 ohms of the form ± 10 V without load Signal span: meander, triangular, ± 10 V at 600 ohm load sawtooth (forward, reverse) ±20 V without load Limits of output signal level adjustment: -sinusoidal shape from 4 mV to 3.7 V (skz) at a load of 600 ohms from 8 mV to 7.4 V (scz) without load -meander, triangular, sawtooth from 10 mV to 10.465 V (span) at a load of 600 ohms shape: from 20 mV to 20.93 V (span) without load Signal level unevenness ± 5% at frequencies from 0.1 to 10 Hz sinusoidal shape relative to ± 2% at frequencies from 10 Hz to 200 kHz 1 kHz ±5% at frequencies from 200 kHz to 2 MHz The harmonic coefficient of the sinusoidal ± 0.2% at frequencies from 10 to 100 Hz forms ± 0.07% at frequencies from 100 Hz to 10 kHz ±2% at frequencies from 10 to 120 kHz ±1% at frequencies from 120 kHz to 1 MHz ±4% at frequencies from 1 to 2 MHz Parameters of the rectangular (TTL) signal form log. "1" 3 2.4 V; log. "0" ≤ 0.4 V the duration of the front, the cutoff is not more than 100 ns in the frequency range from 0.1 Hz to 2 MHz Operating temperature range from minus 10 °C to + 40 °C Power supply ~230 V, 50 Hz; 10 V×A Dimensions; weight 210×71×255 mm; 2 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Power supply B5-89, B5-89/1
Power supply B5-89, B5-89/1
Technical specifications: Indicator name, unit of measurement, Indicator value, B5-89, B5-89/1 The range of the output voltage setting, the limits of the absolute error of the output voltage setting:- basic error, In; - in operating conditions, In, from 0 to 30.0 ± 0.2± 0.3, from 0 to 100.0 ± 0.3± 0.45 The range of the output current setting, the limits of the absolute error of the output current setting:- basic error, A; - in operating conditions, A, from 0 to 10.0 ± 0.2± 0.3, from 0 to 3.0 ± 0.1± 0.15 Instability of the output voltage when the supply voltage changes by ± 10% of the nominal value in the voltage stabilization mode, %, ± 0.05, no more, Instability of the output current when the supply voltage changes by ± 10% of the nominal value in the current stabilization mode, %, ± 0.2, no more, Instability of the output voltage when the load current changes at the output terminals of power supplies in voltage stabilization mode, %, ± 1, no more, Instability of the output current when the load voltage changes in the current stabilization mode at minimum load currents, %, ± 5, no more, Instability of the output current when the load voltage changes in the current stabilization mode at maximum load currents, %, ± 0.5, no more, Output voltage ripple in voltage stabilization mode, mV, 1.0, no more, Output current ripple in current stabilization mode, %, 1, no more, Instability of the output voltage from time, V, ± 0.5, ± 1.0 Instability of the output current from time, A, ± 0.3, ± 0.2 AC power supply: - voltage, V; - frequency, Hz, 230 ± 2350 ± 0.5, Weight, kg, 13.0, no more, Overall dimensions, mm, 384x301x169
MNIPI
Minsk
Produced in: Belarus, Minsk
Power supply B5-86, B5-86/1
Power supply B5-86, B5-86/1
Main Features: Output voltage indication error, ± 0.3 V Output current indication error, ±0.06 A Instability of the output voltage due to changes in the supply voltage, 0.05% Instability of the output current from a change in the supply voltage, 0.2% Instability of the output voltage when the load current changes, 0.1 % Instability of the output current when the load voltage changes, 5.0 % Output voltage ripple, mV 1.0
MNIPI
Minsk
Produced in: Belarus, Minsk
Voltmeter V7-77
Voltmeter V7-77
Technical specifications: DC voltage , Measuring range, 10 mv-1000V Measurement error, ± (0.05% +4 E.M.R.) AC voltage , Measuring range, 1 mV - 750 V Measurement error, ± (0.5% +4 E.M.R.) Frequency range, 20 Hz- 100 kHz Direct current , Measuring range, 0.1 µA - 10 A Measurement error, ± ( 0.25% +4 E.M.R.)
MNIPI
Minsk
Produced in: Belarus, Minsk
Voltmeter V7-72
Voltmeter V7-72
Technical specifications: DC voltage Measuring range 2 mv-1000 V Measurement error ± (0.001 - 0.004)% AC voltage Measuring range 1 mV - 700 V Measurement error ± (0.1-8)% Frequency range 10 Hz -1 MHz
MNIPI
Minsk
Produced in: Belarus, Minsk