Search

46 products
View:
  • Selected: 0
    Applying
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 1
    Additional
All filters
  • 10
    Applying
  • 22
    Names
    Loading...
  • 4
    Manufacturer
  • 4
    Made in
  • Additional
View:
46 products
Universal calibrator H4-301
Universal calibrator H4-301
Technical specifications: Voltage reproduction range Uk 200 mV 0.07 + 0.01 DC: from 50 MV to 600 V, Uk 2 V 0.05 + 0.005 sub-bands (Uk) 200 mV; 2; 20; 200; 600 V Uk 20 V 0.05 + 0.005 Basic error, ± (% of U + % of Uk): Uk 200 V 0.07 + 0.01 Uk 600 V 0.1 + 0.02 Voltage reproduction range UK 200 mV 0.2 + 0.05 AC: from 1 mV to 600 V, Uk 2; 20 V 0.15 + 0.02 sub-bands (Uk) 200 mV; 2; 20; 200; 600 V from 20 Hz to 20 kHz Basic error, ± (% of U + % of Uk): sv. 20 to 40 kHz 0.2 + 0.1 Uk 200 V; 600 V: from 40 Hz to 1 kHz 0.2 + 0.05 Power reproduction range Ik 200 Ma 0.1 + 0.02 DC: from 1 Ma to 5 A, Ik 2; 20; 200 mA 0.1 + 0.01 sub-bands (Ik) 200 Ma; 2; 20; 200 mA; 2; 5 A Ik 2 A; 5 A 0.1 + 0.02 Basic error, ± (% of I + % of Ic): AC power reproduction range: from 10 Ma to 5 A sub-bands (Ic) 200 Ma; 2; 20; 200 mA; 2; 5 A 0.15 + 0.05 Frequency range from 20 Hz to 1 kHz Basic error, ± (% of I + % of Ic): USB interface Operating temperature range from minus 10 °C to + 50 °C Dimensions; weight 420×342×184.5 mm; 10 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
High-voltage test unit UPU-22
High-voltage test unit UPU-22
Technical specifications: Output voltage (DC and AC), 0 - 2 kV; 0 - 5 kV Built-in AC power supply, 10 - 25 A The amplitude value of the DC voltage ripple relative to the set output voltage of 5 kV at idle is not more than ± 5% Error in setting the output voltage, ± 3% Protection tripping current, 101 -- 140 mA Load current of DC and AC output voltage, not less than 1 mA The limit of measuring the resistance of the integrity of the circuit connection, 0, 01 – 0.10 ohms
MNIPI
Minsk
Produced in: Belarus, Minsk
Generator G6-46
Generator G6-46
Technical specifications: Frequency range, from 0.1 Hz to 1 Frequency range, from 0.1 Hz to 1 MHz Frequency setting error, ± 1 % Signal amplitude: - at a load of 600 ohms - without load, not less than 5 V (10 V span) not less than 10 V (20 V span)Smooth signal attenuation, at least 20 dB Frequency stability in 15 minutes, no more than 0.5% Hz Frequency setting error, ± 1 % Signal amplitude: - at a load of 600 ohms - without load, not less than 5 V (10 V span) not less than 10 V (20 V span) Smooth signal attenuation, at least 20 dB Frequency instability in 15 minutes, no more than 0.5 %
MNIPI
Minsk
Produced in: Belarus, Minsk
Immitance meter E7-25
Immitance meter E7-25
Technical specifications: Conductivity (Gp) - 10-11 – 10 Cm Resistance (Rs, Rp, Xs, |Z|) 10-5 – 109 Ohms Capacity (Ss, Cp) - 10-15 – 1 F Inductance (Ls, Lp) 10-11 – 104 Gn Dobrotn.(Q), loss angle tangent (tg) 10-4 – 104 Phase shift angle of the resistance set -180° – +180° Leakage current (I) - 10-7 – 10-3 A Measurement error - ± 0.15 % Operating frequencies – 25 Hz – 1 MHz Power consumption - 10 VA Overall dimensions - 225x110x35 mm Weight - 0.8 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Meters of parameters of semiconductor devices IPPP-3, IPPP-3/1
Meters of parameters of semiconductor devices IPPP-3, IPPP-3/1
General characteristics: LCD screen 12.1" with a resolution of 1024 x 768, keyboard, mouse. USB, Ethernet. Supply voltage: 230 V / 50 Hz, power: 450 V·A. Operating temperature range: from +5° to +40°C. Dimensions (W x H x D): 470 x 330 x 570 mm, weight: 37 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Workplace of Classic series
Workplace of Classic series
When lining up, Classic series desktops fit snugly together, without forming cracks and gaps. The universal design of the table frame allows you to further equip the workplace with a suspended pedestal and other necessary equipment. Additionally, work tables of Classic series can be equipped with a number of modules: electrical and perforated panels, overhead and local lighting, shelves for equipment, hanging cabinets, corner tables, etc.
DIPAUL
Saint Petersburg
Produced in: Saint Petersburg
Functional signal generator G6-50
Functional signal generator G6-50
Technical specifications: The waveform is sinusoidal, meander, triangular, sawtooth, (straight, reverse), offset, rectangular (TTL) Frequency range from 0.1 Hz to 2 MHz Frequency setting error ±0.05% Frequency instability ±0.02% in 15 min The amplitude of the signal is sinusoidal ± 5 V at a load of 600 ohms of the form ± 10 V without load Signal span: meander, triangular, ± 10 V at 600 ohm load sawtooth (forward, reverse) ±20 V without load Limits of output signal level adjustment: -sinusoidal shape from 4 mV to 3.7 V (skz) at a load of 600 ohms from 8 mV to 7.4 V (scz) without load -meander, triangular, sawtooth from 10 mV to 10.465 V (span) at a load of 600 ohms shape: from 20 mV to 20.93 V (span) without load Signal level unevenness ± 5% at frequencies from 0.1 to 10 Hz sinusoidal shape relative to ± 2% at frequencies from 10 Hz to 200 kHz 1 kHz ±5% at frequencies from 200 kHz to 2 MHz The harmonic coefficient of the sinusoidal ± 0.2% at frequencies from 10 to 100 Hz forms ± 0.07% at frequencies from 100 Hz to 10 kHz ±2% at frequencies from 10 to 120 kHz ±1% at frequencies from 120 kHz to 1 MHz ±4% at frequencies from 1 to 2 MHz Parameters of the rectangular (TTL) signal form log. "1" 3 2.4 V; log. "0" ≤ 0.4 V the duration of the front, the cutoff is not more than 100 ns in the frequency range from 0.1 Hz to 2 MHz Operating temperature range from minus 10 °C to + 40 °C Power supply ~230 V, 50 Hz; 10 V×A Dimensions; weight 210×71×255 mm; 2 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Voltmeter V7-72
Voltmeter V7-72
Technical specifications: DC voltage Measuring range 2 mv-1000 V Measurement error ± (0.001 - 0.004)% AC voltage Measuring range 1 mV - 700 V Measurement error ± (0.1-8)% Frequency range 10 Hz -1 MHz
MNIPI
Minsk
Produced in: Belarus, Minsk