Pure Hydrogen Generator GVCH-12M1
Pure Hydrogen Generator GVCH-12M1
from 190 800 ₽
The characteristics of the device are similar to the GVCH-12A model; the difference is in the absence of an autoregeneration system for fine gas filters. Technical specifications Purity of hydrogen in terms of dry gas is about 99.9999% The concentration of water vapor at 20 ° C and 1 atm is not more than 5 ppm In the output pressure stabilization mode The range of the specified output pressure of hydrogen is from 1.5 to 6.1 ati Stability of the output pressure of hydrogen is not worse than ± 0.02 ati Maximum hydrogen capacity reduced to normal conditions is 12 l/h The time of setting the operating mode, with the output turned off is no more than 30 min In the performance stabilization mode: The range of the specified hydrogen performance is from 0 to 12 l/h Maximum developed pressure in performance mode is 5.0 ati Volume of distilled water to be poured is 1.0 l Distilled water consumption is no more than 0.02 l/hour Water consumption is 1.6 g/l of hydrogen The average life of a replaceable deionization filter cartridge (at maximum performance and single-shift operation) is at least 1 year Average power consumption: in stationary mode is no more than 150 VA maximum (at startup) is no more than 200 VA Overall dimensions of the generator, (width x depth x height) are not more than 230x470x450 mm The mass of the generator is not more than 15 kg Operating conditions: ambient temperature, °C, from +10 to +35 powered by single-phase AC voltage, V, 220 (+10 -15)% and frequency, Hz, 50 ± 1 The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
UPVD 5-4 Water Deionizer
UPVD 5-4 Water Deionizer
from 39 000 ₽
The UPVD deionizer is suitable for enterprises, research centers and laboratories where type 2 water is required for laboratory analysis with an electrical conductivity of no more than 1.0 mcm/cm. Overall dimensions (LxWxH) 390×180×400 mm Weight 9 kg
Livam
Belgorod
Produced in: Belgorod
UPVD 10-4 Water Deionizer
UPVD 10-4 Water Deionizer
from 43 200 ₽
The UPVD deionizer is suitable for enterprises, research centers and laboratories where type 2 water is required for laboratory analysis with an electrical conductivity of no more than 1.0 mcm/cm. Overall dimensions (LxWxH) 400×200×500 mm Weight 11.5 kg
Livam
Belgorod
Produced in: Belgorod
Pure nitrogen generator GCHA-18-K
Pure nitrogen generator GCHA-18-K
from 396 000 ₽
The characteristics of the device are similar to the GCHA-18 model; the difference is that the oil–free compressor built into the GCHA-18-K generator provides complete autonomy of the device. The warranty for the device is 18 months, for the built-in compressor-12 months from the date of sale.
Produced in: Moscow
Medical Electric Aquadistillator ADE-09
Medical Electric Aquadistillator ADE-09
from 22 900 ₽
Capacity: 1.0 l/h The quality of the produced water: FS.2.2.0020.18 " Purified water" Type of current, frequency, voltage: alternating single-phase, 50 Hz, 220 V Power consumption: 0.75 kW Overall dimensions (L×W×C), mm: 230x250x365 Weight: 3.9 kg Warranty period: 14 months from the date of sale
Livam
Belgorod
Produced in: Belgorod
Device "Aquarius-M"
Device "Aquarius-M"
from 210 000 ₽
It is intended for obtaining analytical purity in laboratory conditions from distilled water, used for HPLC, electrophoresis, preparation of solutions, chromatographic samples, refueling of electrolysis generators of hydrogen/oxygen and other purposes. Technical specifications The specific resistance of the received water is not less than 17.5 MOmhsm Productivity is not less than 1 l/hour Metal ion content is not more than: Fe, Pb, Ni, Co 5 mcG/l Zn 0,5 mcG/l Cd, Cu, Mn 0,1 mcG/l The content of ammonium ions is not more than 100 mcG/l The number of bacteria is not more than 5 CFU/ml Operating time of replaceable cartridges (total volume of purified water) is not less than 300 liters Volume of refilled distilled water is 1 l Overall dimensions are 210x590x455 mm The mass of the filled device is not more than 15 kg Working conditions: ambient temperature from +15 to +35 °C Power supply from single-phase AC 220 V, 50 Hz Power consumption is not more than 50 VA
Produced in: Moscow
Pure nitrogen generator GCHA-120
Pure nitrogen generator GCHA-120
from 382 800 ₽
GCHA-120 nitrogen generators are designed to produce in laboratory conditions nitrogen of the highest purity that is used to power analytical instruments, boxes with an inert atmosphere. Technical specifications The grade of nitrogen produced according to GOST 9293-74 is high purity, grade I Volume fraction of nitrogen is not less than % by volume (including impurities of inert gases — argon, neon, helium) 99.999 Volume fraction of oxygen is not more than, % vol. 0.0005 (5 ppm) Volume fraction of water vapor is not more than, % vol. 0.0007 (7 ppm) Volume fraction of hydrogen is not more than, % vol. (ppm) 0.0002 (2 ppm) The volume fraction of the sum of carbon-containing compounds in terms of methane is not more than, % vol. (ppm)* (with a methane content in the supply air of not more than 4 ppm) 0.0003 (3 ppm) Maximum nitrogen capacity is at least 120 (2.0 l/min), l/h Nominal nitrogen output pressure (with the throttle open) is 4 ati The time of setting the operating mode for single-shift operation is no more than 45 min Nominal inlet air pressure is 6 ati Maximum allowable inlet air pressure is 8 ati Minimum inlet air pressure is 5.5 ati Compressed air consumption, at nominal inlet pressure and maximum flow rate is no more than, l/h, 3600 (60 l/min) Power consumption is not more than, VA, 100 Overall dimensions, (width x depth x height) are not more than, mm, 230x580x680; Weight is not more than, kg 32 Working conditions: ambient temperature, C°, from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow